StaNDarD rEgulator wIth ElaStoMErIC DIaPhragM

vIEw b — MEtal DIaPhragM For StaNDarD rEgulator

SoFt SEat oPtIoN

vaCuuM ProtECtIoN oPtIoN

t-haNDlE oPtIoN

Figure 1. 

Type SR5 Sanitary Regulator Assembly

Parts list 

Key   Description 

1  

Body

2  

Plug (metal seat)

3  

Plug O-Ring

4  

Diaphragm Plate O-Ring

5  

Piston Ring

6  

Diaphragm Gasket

7  

Diaphragm

8  

Lower Spring Seat

9  

Guide Ring

10  

Diaphragm Plate

11  

Upper Spring Seat

12  

Spring 

13  

Inner Spring 

14  

Spring Case

15  

Bolted Clamp

16  

Hex Nut

17  

Hex Nut

18  

Adjusting Screw

19  

Closing Cap

22  

Locking Lever

23  

Flat Washer

24 

Lock Washer

26  

Upper Plug

27  

Lower Plug

28  

Soft Seat

30  

Ring Grip Pin

31  

Bead Chain 

Key   Description 

Содержание Fisher SR5

Страница 1: ...Maximum Inlet Pressure 14 5 bar at 65 C 210 psig at 150 F 12 4 bar at 135 C 180 psig at 275 F 11 bar at 204 C 160 psig at 400 F Maximum Outlet Pressure 10 3 bar at 65 C 150 psig at 150 F 8 62 bar at 135 C 125 psig at 275 F 7 58 bar at 204 C 110 psig at 400 F Proof Test Pressure All Pressure Retaining Components have been proof tested per Directive 97 23 EC Annex 1 Section 7 4 Outlet Pressure Range...

Страница 2: ...or inlet pressure is greater than the safe working pressure of the downstream equipment Regulator operation below the maximum pressure limitations does not preclude the possibility of damage from external sources or debris in the line The regulator should be inspected for damage after any overpressure condition Startup The regulator is factory set at approximately the midpoint of the spring range ...

Страница 3: ...escription 1 Body 2 Plug metal seat 3 Plug O Ring 4 Diaphragm Plate O Ring 5 Piston Ring 6 Diaphragm Gasket 7 Diaphragm 8 Lower Spring Seat 9 Guide Ring 10 Diaphragm Plate 11 Upper Spring Seat 12 Spring 13 Inner Spring 14 Spring Case 15 Bolted Clamp 16 Hex Nut 17 Hex Nut 18 Adjusting Screw 19 Closing Cap 22 Locking Lever 23 Flat Washer 24 Lock Washer 26 Upper Plug 27 Lower Plug 28 Soft Seat 30 Rin...

Страница 4: ...ility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any Emerson Process Management product remains solely with the purchaser Fisher Controls International Inc 2004 2006 All Rights Reserved Industrial USA Headquarters McKinney Texas 75070 USA Tel 1 800 558 5856 Outside U S 1 469 293 4201 Asia Pacific Shanghai China 201206 Tel 86 21 58...