background image

Trouble Shooting

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fan will not start.

1. Fuse or circuit breaker blown.

1. Check main and branch circuit fuses or circuit breakers.

2. Loose power line connections to the fan, or loose  2. Check line wire connections to fan and switch wire 

switch wire connections in the switch housing.

connections in the switch housing.

CAUTION: Make sure main power is turned off.

3. Reversing switch in neutral position.

3. Make sure reversing switch position is all the way to one 

side.

2. Fan sounds noisy.

1. Blades not attached to fan.

1. Attach blades to fan before operating.

2. Screws securing fan blade flanges to motor are

2. Check to make sure the screws which attach the fan 

loose.

flanges to the motor are tight. 

3. Screws holding blades to flanges are loose.

3. Tighten screws securely.

4. Glass bowl loose.

4. Tighten the glass bowl securely.

3. Fan wobbles

1. Setscrew in motor coupling is loose.

1. Raise coupler cover and tighten the setscrew securely.

excessively.

2. Setscrew in hanger ball/downrod assembly is

2. Tighten the setscrew in the hanger ball/downrod assembly.

loose.

3. Screws securing fan blade flanges to motor are

3. Check to be sure screws which attach the fan blade

loose.

flanges to the motor are tight.

4. Fan blade flanges not seated properly.

4. Check to be sure the fan blade flanges seat firmly and

uniformly to the surface of the motor. If flanges are
seated incorrectly, loosen the flange screws and retighten 
according to the procedure in the section on "How to Put
Your Ceiling Fan Together".

5. Hanger bracket and/or ceiling outlet box is not    

5. Tighten the hanger bracket screws to the outlet box, and/or 

securely fastened.

secure outlet box. 

6. Fan blades out of balance.

6. Interchanging an adjacent (side-by-side) blade pair can 

redistribute the weight and result in smoother operation.

1. Restore electrical power to the outlet box by turning

the electricity on at the main fuse box or circuit
breaker panel.

2. All fans are shipped from the factory with the

reversing switch positioned to circulate air
downward. If airflow is desired in opposite direction,
turn your fan off and wait for the blades to stop

turning, then slide the reversing switch to (located
at the top of the motor housing) opposite position,
and turn fan on again. The fan blades will turn in
the opposite direction and reverse the airflow.

3. Refer to the Owner’s Manual supplied with the

SR100 Fan/Light Control for operation of the fan
and light.

7

Using Your Ceiling Fan

Installing Glass Globe

WARNING: 

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER

BEFORE TROUBLE SHOOTING YOUR FAN.

1. Install three candelabra base bulbs in sockets.

2. Place the glass bowl into the opening in the light kit

plate, aligning the three flat areas on the top edge
of the glass with the three raised dimples on the
light kit plate and turn the glass bowl clockwise until
it stops (Figure 13).

NOTE: periodically check that the glass bowl is
seated fully clockwise in the light kit plate.

RAISED
DIMPLES

LIGHT KIT
PLATE

FLAT AREA

Figure 13

Содержание COOLER CF925BK00

Страница 1: ...uct to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covere...

Страница 2: ...upporting a least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan bl...

Страница 3: ... step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan assembly fro...

Страница 4: ...Place the ceiling cover over the downrod Be sure both the ceiling cover and the coupler cover are oriented correctly Figure 3 5 Reinstall the hanger ball Figure 4 on the downrod as follows Route the motor leads through the downrod Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight...

Страница 5: ...wire from the light kit plate to the blue wire from the motor Figure 7 Make sure the connectors are fully engaged 12 Position the light kit plate so that the studs on the adapter plate protrude through the three holes in the light kit plate Install a 3 16 24 nut on each stud NOTE Be sure the wires are not pinched between the light kit plate and the spacers or motor shaft LIGHT KIT PLATE 3 16 24 NU...

Страница 6: ...ET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 9 Figure 10 Figure 11 The fan must be hung with at least 7 of clearance from floor to blades Figure 9 WARNING The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs WARNING To reduce the risk of fire electric shock or personal injury mo...

Страница 7: ...flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box and or securely fastened secure outlet box 6 Fan blades out of balance 6 Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation 1 ...

Страница 8: ... ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 EMERSON Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant St Louis MO 63136 Part No F40BP72050004 Printed in Taiwan 09 99 F...