1. Remove the hanger ball by loosening the setscrew

in the hanger ball until the ball falls freely down the
downrod (Figure 1). Remove the clevis pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in step 5.

2. Loosen setscrew in motor coupling if necessary.

Separate, untwist and unkink the three 80” motor
leads. Route the motor lead wires through the
downrod. Align the clevis pin holes in the downrod
with the holes in the motor coupling. Install the
clevis pin and secure with the hairpin clip (Figure
2). The clevis pin must go through the holes in the
motor coupling and the holes in the downrod. Be
sure to push the straight leg of the hairpin clip
through the hole near the end of the clevis pin until
the curved portion of the hairpin clip snaps around
the clevis pin. The hairpin clip must be properly
installed to prevent the clevis pin from working
loose. Pull on the downrod to make sure the clevis
pin is properly installed.

3. While pulling up on the downrod, securely tighten

the setscrew in the motor coupling (Figure 3).

NOTE: The setscrew must be properly installed as
described above, or fan wobble could result.

SETSCREW

CLEVIS PIN

MOTOR
COUPLING

DOWNROD

HAIRPIN
CLIP

Figure 2

4. Make sure the grommet is properly installed in the

coupling cover then slide the coupler cover on the
downrod until it rests on the motor housing. Place
the ceiling cover over the downrod. Be sure both
the ceiling cover and the coupler cover are
oriented correctly (Figure 3).

5. Reinstall the hanger ball (Figure 4) on the downrod

as follows. Route the motor leads through the
downrod. Position the pin through the two holes in
the downrod and align the ball so the pin is captured
in the groove in the top of the hanger ball. Pull the
hanger ball up tight against the pin and securely
tighten the setscrew in the hanger ball. A loose
setscrew could create fan wobble.

6. The fan comes with blue, black and white leads

that are 80” long. Before installing fan, measure up
approximately 6 to 9-inches above top of hanger
ball/downrod assembly. Cut off excess leads and
strip back insulation 1/2-inch from end of leads.

7. Mount blade flanges to fan blades using three 

3/16-24 x 5/16” slotted Phillips washer head blade
screws and three fiber blade washers (Figure 5).

PIN

SETSCREW

HANGER
BALL

DOWNROD

Figure 4

4

COUPLER
COVER

MOTOR
COUPLING

CLEVIS
PIN

SETSCREW

HAIRPIN
CLIP

CLEVIS
PIN

CEILING
COVER

Figure 3

PIN

SETSCREW

HANGER
BALL

DOWNROD

Figure 1

How to Put Your Ceiling Fan Together

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely
tightened. Failure to verify that the pin and setscrew
are properly installed (as shown in Figure 2) could
result in the fan falling.

WARNING

!

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.

WARNING

!

Содержание COOLER CF925BK00

Страница 1: ...uct to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covere...

Страница 2: ...upporting a least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan bl...

Страница 3: ... step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan assembly fro...

Страница 4: ...Place the ceiling cover over the downrod Be sure both the ceiling cover and the coupler cover are oriented correctly Figure 3 5 Reinstall the hanger ball Figure 4 on the downrod as follows Route the motor leads through the downrod Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight...

Страница 5: ...wire from the light kit plate to the blue wire from the motor Figure 7 Make sure the connectors are fully engaged 12 Position the light kit plate so that the studs on the adapter plate protrude through the three holes in the light kit plate Install a 3 16 24 nut on each stud NOTE Be sure the wires are not pinched between the light kit plate and the spacers or motor shaft LIGHT KIT PLATE 3 16 24 NU...

Страница 6: ...ET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 9 Figure 10 Figure 11 The fan must be hung with at least 7 of clearance from floor to blades Figure 9 WARNING The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs WARNING To reduce the risk of fire electric shock or personal injury mo...

Страница 7: ...flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box and or securely fastened secure outlet box 6 Fan blades out of balance 6 Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation 1 ...

Страница 8: ... ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 EMERSON Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant St Louis MO 63136 Part No F40BP72050004 Printed in Taiwan 09 99 F...

Отзывы: