147
Diagnostics and Troubleshooting
Diagnostic Display
The diagnostic display on the front of the drive shows drive status and fault codes. When a
fault condition occurs, the drive will display the fault code, overriding the status code. The
decimal point is “On” when the drive is enabled and the Stop input is not active. This indicates
that the drive is ready to run and will respond to motion commands. Commands will not cause
motion unless the decimal point is “On”.
Display Indication
Status
Description
Brake Engaged (Output "Off")
Motor brake is mechanically engaged. This character
will only appear if the Brake output function is
assigned to an output line.
See Brake Operation section for detailed description of
Brake Output function.
Disabled
Power Stage is disabled.
Position
Pulse mode operation.
Velocity
Velocity mode operation.
Torque
Torque mode operation.
Summation
Summation mode operation.
RMS Foldback
Motor torque is limited to 80 percent.
Stall Foldback
(EN drive only)
Drive output current is limited to 80 percent of drive
stall current.
Epsilon Eb and EN Drives Reference Manual