background image

9

ETL Model No.: CF955-3

How to Put Your Ceiling Fan Together 

(continued)

13.

Attach the lower housing assembly to the fan motor
using the two key slot holes. (Figure 7). Secure the
lower housing assembly by tightening the two
screws. Reinstall and tighten the two screws that
were removed.

NOTE: Make sure wires and terminals are
positioned in raised center area of lower housing
assembly, and not pinched between fan and light
kit.

LOWER
HOUSING
ASSEMBLY

RAISED CENTER
AREA OF LIGHT
KIT HOUSING

SCREWS (2)

KEY
SLOT
HOLE (2)

Figure 7

Electrical Requirements

If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture.

Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and
capable of withstanding a load of at least 50 pounds.

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable
for Fan Support”, and use screws supplied with
outlet box. Most outlet boxes commonly used for
support of light fixtures are not acceptable for fan
support and may need to be replaced. Consult a
qualified electrician if in doubt.

WARNING

!

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring. All
wiring must be in accordance with National and
Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.

WARNING

!

To avoid fire or shock, follow all wiring instructions
carefully.
Any electrical work not described in these
instructions should be done or approved by a
licensed electrician.

WARNING

!

Pour réduire le risque d'incendie, de choc électrique ou
de blessures, ne montez le ventilateur que dans un
boîtier de prises de courant comportant les termes
« Acceptable pour le raccordement d'un ventilateur »,
et utilisez les vis fournies avec le boîtier. La plupart des
boîtiers de prises de courant utilisés couramment pour
le raccordement de luminaires ne sont pas acceptables
pour le raccordement de ventilateurs et devront
peut-être être remplacés. Consultez un électricien
professionnel en cas de doute.

AVERTISSEMENT 

!

Il n'est pas suffisant de couper l'alimentation au niveau
du commutateur mural. Pour éviter tout risque de choc
électrique, assurez-vous que l'électricité est coupée au
niveau du disjoncteur/boîtier de fusibles avant de
commencer le câblage. Tout le câblage doit être
conforme aux codes nationaux et locaux, et le
ventilateur de plafond doit être mis à la terre de façon
correcte pour éviter tout risque de décharge électrique.

AVERTISSEMENT 

!

Suivez soigneusement toutes les instructions de
câblage pour éviter tout risque d'incendie ou de choc
électrique. Tout travail électrique qui n'est pas décrit
dans ces instructions doit être effectué ou approuvé par
un électricien professionnel.

AVERTISSEMENT 

!

Содержание CF955BS 03

Страница 1: ...mbers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we...

Страница 2: ...ecommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician NOTE This fan is suitable for use with solid state speed controls WARNING To reduce the risk of fire or electrical shock this fan should only be used with fan speed control Model No FR 7861LMA manufactured by Rhine Electric Co ...

Страница 3: ...t boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Installation of Blade Assembly page 8 1 Turn fan assembly upside down in preparation for mounting fan blade assemblies 2 To ensure proper blade assembly make sure the label on the blades are facing the bottom of the ceiling fan Slide...

Страница 4: ...fail change the remote code and repeat Steps 1 and 2 as necessary until the fan successfully completes the programming procedure NOTE Fan installation must be completed including the installation of the fan blades before testing the remote control 4 Your SR600 Fan Light remote control has full control of your fan speed air flow direction and light intensity NOTE The following procedure must be com...

Страница 5: ...remote control transmitter i One coupler cover j Four 13 watt GU 24 fluorescent lamps k One loose parts bag containing 1 Sixteen 3 16 24 x 1 2 slotted Phillips washer head blade screws 2 Three wire connectors 3 Two 1 1 4 threaded studs 4 Two lockwashers 5 Two knurled knobs 6 One clevis pin 7 One hairpin clip 8 One 1 25A 125V fuse spare 9 One 5 32 32 x 375 pan head screw spare 10 One 5 32 32 x 75 s...

Страница 6: ...our Emerson ceiling fan comes supplied with a Fan Light Remote Control which consists of a receiver mounted inside the ceiling cover of the fan motor housing This system allows you to regulate your ceiling fan speed and light ON OFF 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves ...

Страница 7: ...properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed 3 While pulling up on the downrod securely tighten the setscrew in the motor coupling Figure 3 NOTE The setscrew must be properly installed as described above or fan wobble could result 4 Remove the three screws pre installed on top of the fan assembly and retain fo...

Страница 8: ...LL Figure 4 MOTOR HUB 3 16 24 x 1 2 SLOTTED PHILLIPS WASHER HEAD BLADE SCREWS FAN BLADE BLADE SLOT IN HOUSING LABEL LOCATED ON BOTTOM OF BLADE Figure 5 TERMINALS LOWER HOUSING ASSEMBLY FAN MOTOR ASSEMBLY REMOVE 2 SCREWS LOOSEN 2 SCREWS FUSE AND FUSE HOLDER Figure 6 8 The fan comes with black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above top of ...

Страница 9: ...ore wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician WARNING Pour réduire le risque d incendie de choc...

Страница 10: ... montées solidement et être capables de supporter au moins 50 lbs 22 5 kg Utilisez seulement un boîtier de prises de courant homologué U L comportant les termes Acceptable pour le raccordement d un ventilateur AVERTISSEMENT CEILING FLOOR AT LEAST 7 Figure 8 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 9 Hanger bracket must seat firmly against outlet box If the outlet bo...

Страница 11: ...s grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING Pour ne pas risquer de choc électrique assurez vous que l électricité est coupée au niveau du disjoncteur boîtier de fusibles avant de réaliser le raccordement REMARQUE si vous ne savez pas vraiment si le boîtier de prises de courant est mis à la terre contactez un électricien professionnel pour ...

Страница 12: ... turn until studs protrude through the holes in the ceiling cover Figure 12 Effectuez une inspection pour vous assurer que toutes les connexions sont bien serrées y compris la connexion de mise à la terre et qu aucun fil nu n est visible près des connecteurs à l exception du fil de mise à la terre Ne mettez pas le ventilateur en marche avant que les pales ne soient à leur place Ceci causerait un f...

Страница 13: ...ur fan and light go on and off without using your control you may be getting interference from other remote units such as garage door openers car alarms or security systems To remedy this situations simply change the combination code in your transmitter and receiver 1 Remove the battery cover by pressing firmly below the arrow and sliding the cover off the control Figure 14 2 Install two AAA alkal...

Страница 14: ...g the receiver Program the receiver to the new frequency by repeating the Setting Operating Frequency of Remote Control and High Speed Conditioning instructions IMPORTANT The following steps must be completed immediately following the frequency programming of the ceiling fan 1 Press the speed button until all 6 LED indicators are lit Let the fan operate on high speed for 2 minutes without interrup...

Страница 15: ...cessory Ceiling Fan Controls SR600 Handheld Transmitter SW605 Wall Transmitter SR650 Wall Handheld Transmitter WARNING N utilisez pas d eau lorsque vous nettoyez votre ventilateur de plafond Cela risquerait d endommager le moteur ou les lames et de créer le risque de choc électrique AVERTISSEMENT L utilisation de toute autre commande non approuvée spécifiquement pour ce ventilateur risquerait de c...

Страница 16: ...ger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box securely fastened and or secure outlet box 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise coupler cover and tighten the setscrew securely excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod loose assembly 3 Screws securing fan flywh...

Страница 17: ...se the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certified to comply with the limits for a class B computing device pursuant to FCC Rules In order to maintain compliance with FCC regulations shielded c...

Страница 18: ...Repair Parts 18 ETL Model No CF955 3 9 14 8 20 15 13 19 21 4 6 7 17 18 1 2 3 5 12 16 10 11 ...

Страница 19: ...rts Bag Containing 762029 2 762029 1 762029 2 4 Wire Connector 3 5 Stud Threaded 1 1 4 2 6 Lockwashers 2 7 Knob Knurled 2 8 Pin Clevis 9 Clip Hairpin 10 Screw Slotted Phillips Washer Head 3 16 24 x 1 2 16 11 Screw Pan Head 5 32 32 x 375 spare 12 Screw Slotted Head 5 32 32 x 75 spare 13 Fuse 1 25A 125V spare 14 Lower Housing Assembly 763746 763746 2 763746 1 15 Glass Shade 762031 762031 762031 16 B...

Страница 20: ...thorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass ...

Отзывы: