background image

8

How to Put Your Ceiling Fan Together 

(continued)

7.

Reinstall the hanger ball (Figure 4) on the downrod
as follows. Route the motor leads through the
downrod. Position the pin through the two holes in
the downrod and align the ball so the pin is captured
in the groove in the top of the hanger ball. Pull the
hanger ball up tight against the pin and securely
tighten the setscrew in the hanger ball. A loose
setscrew could create fan wobble.

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.

WARNING

!

Il est crucial que l'axe dans le cylindre de suspension
soit installé correctement et que la vis de blocage soit
bien serrée. Si vous ne vous assurez pas que l'axe et la
vis sont installés correctement, le ventilateur risquerait
de tomber.

AVERTISSEMENT 

!

CEILING COVER

DOWNROD

PIN

SETSCREW

HANGER
BALL

Figure 4

MOTOR
HUB

3/16-24 x 1/2" SLOTTED
PHILLIPS WASHER HEAD
BLADE SCREWS

FAN BLADE

BLADE SLOT
IN HOUSING

LABEL
(LOCATED ON
BOTTOM OF BLADE)

Figure 5

TERMINALS

LOWER 
HOUSING
ASSEMBLY

FAN MOTOR
ASSEMBLY

REMOVE 
2 SCREWS

LOOSEN 
2 SCREWS

FUSE AND 
FUSE HOLDER

Figure 6

8.

The fan comes with black and white leads that
are 80” long. Before installing fan, measure up
approximately 6 to 9-inches above top of hanger
ball/downrod assembly. Cut off excess leads and
strip back insulation 1/2-inch from end of leads.

9.

Turn fan assembly upside down in preparation for
mounting fan blades.

10.

To ensure proper blade assembly, make sure the
label on the blades are facing the bottom of the
ceiling fan. Slide blade through center slot in fan
housing. Mount blades to fan housing using three 
3/16-24 x 1/2” slotted Phillips washer head blade
screws on each blade (Figure 5).

NOTE: Take care not to scratch fan housing when
installing blades.

11.

Remove two of the four screws in the motor
assembly and loosen the remaining two screws
(Figure 6).

12.

Connect the terminals of the lower housing
assembly to the terminals of the fan motor
assembly (Figure 6).

ETL Model No.: CF955-3

Содержание CF955BS 03

Страница 1: ...mbers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we...

Страница 2: ...ecommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician NOTE This fan is suitable for use with solid state speed controls WARNING To reduce the risk of fire or electrical shock this fan should only be used with fan speed control Model No FR 7861LMA manufactured by Rhine Electric Co ...

Страница 3: ...t boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Installation of Blade Assembly page 8 1 Turn fan assembly upside down in preparation for mounting fan blade assemblies 2 To ensure proper blade assembly make sure the label on the blades are facing the bottom of the ceiling fan Slide...

Страница 4: ...fail change the remote code and repeat Steps 1 and 2 as necessary until the fan successfully completes the programming procedure NOTE Fan installation must be completed including the installation of the fan blades before testing the remote control 4 Your SR600 Fan Light remote control has full control of your fan speed air flow direction and light intensity NOTE The following procedure must be com...

Страница 5: ...remote control transmitter i One coupler cover j Four 13 watt GU 24 fluorescent lamps k One loose parts bag containing 1 Sixteen 3 16 24 x 1 2 slotted Phillips washer head blade screws 2 Three wire connectors 3 Two 1 1 4 threaded studs 4 Two lockwashers 5 Two knurled knobs 6 One clevis pin 7 One hairpin clip 8 One 1 25A 125V fuse spare 9 One 5 32 32 x 375 pan head screw spare 10 One 5 32 32 x 75 s...

Страница 6: ...our Emerson ceiling fan comes supplied with a Fan Light Remote Control which consists of a receiver mounted inside the ceiling cover of the fan motor housing This system allows you to regulate your ceiling fan speed and light ON OFF 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves ...

Страница 7: ...properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed 3 While pulling up on the downrod securely tighten the setscrew in the motor coupling Figure 3 NOTE The setscrew must be properly installed as described above or fan wobble could result 4 Remove the three screws pre installed on top of the fan assembly and retain fo...

Страница 8: ...LL Figure 4 MOTOR HUB 3 16 24 x 1 2 SLOTTED PHILLIPS WASHER HEAD BLADE SCREWS FAN BLADE BLADE SLOT IN HOUSING LABEL LOCATED ON BOTTOM OF BLADE Figure 5 TERMINALS LOWER HOUSING ASSEMBLY FAN MOTOR ASSEMBLY REMOVE 2 SCREWS LOOSEN 2 SCREWS FUSE AND FUSE HOLDER Figure 6 8 The fan comes with black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above top of ...

Страница 9: ...ore wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician WARNING Pour réduire le risque d incendie de choc...

Страница 10: ... montées solidement et être capables de supporter au moins 50 lbs 22 5 kg Utilisez seulement un boîtier de prises de courant homologué U L comportant les termes Acceptable pour le raccordement d un ventilateur AVERTISSEMENT CEILING FLOOR AT LEAST 7 Figure 8 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 9 Hanger bracket must seat firmly against outlet box If the outlet bo...

Страница 11: ...s grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING Pour ne pas risquer de choc électrique assurez vous que l électricité est coupée au niveau du disjoncteur boîtier de fusibles avant de réaliser le raccordement REMARQUE si vous ne savez pas vraiment si le boîtier de prises de courant est mis à la terre contactez un électricien professionnel pour ...

Страница 12: ... turn until studs protrude through the holes in the ceiling cover Figure 12 Effectuez une inspection pour vous assurer que toutes les connexions sont bien serrées y compris la connexion de mise à la terre et qu aucun fil nu n est visible près des connecteurs à l exception du fil de mise à la terre Ne mettez pas le ventilateur en marche avant que les pales ne soient à leur place Ceci causerait un f...

Страница 13: ...ur fan and light go on and off without using your control you may be getting interference from other remote units such as garage door openers car alarms or security systems To remedy this situations simply change the combination code in your transmitter and receiver 1 Remove the battery cover by pressing firmly below the arrow and sliding the cover off the control Figure 14 2 Install two AAA alkal...

Страница 14: ...g the receiver Program the receiver to the new frequency by repeating the Setting Operating Frequency of Remote Control and High Speed Conditioning instructions IMPORTANT The following steps must be completed immediately following the frequency programming of the ceiling fan 1 Press the speed button until all 6 LED indicators are lit Let the fan operate on high speed for 2 minutes without interrup...

Страница 15: ...cessory Ceiling Fan Controls SR600 Handheld Transmitter SW605 Wall Transmitter SR650 Wall Handheld Transmitter WARNING N utilisez pas d eau lorsque vous nettoyez votre ventilateur de plafond Cela risquerait d endommager le moteur ou les lames et de créer le risque de choc électrique AVERTISSEMENT L utilisation de toute autre commande non approuvée spécifiquement pour ce ventilateur risquerait de c...

Страница 16: ...ger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box securely fastened and or secure outlet box 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise coupler cover and tighten the setscrew securely excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod loose assembly 3 Screws securing fan flywh...

Страница 17: ...se the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certified to comply with the limits for a class B computing device pursuant to FCC Rules In order to maintain compliance with FCC regulations shielded c...

Страница 18: ...Repair Parts 18 ETL Model No CF955 3 9 14 8 20 15 13 19 21 4 6 7 17 18 1 2 3 5 12 16 10 11 ...

Страница 19: ...rts Bag Containing 762029 2 762029 1 762029 2 4 Wire Connector 3 5 Stud Threaded 1 1 4 2 6 Lockwashers 2 7 Knob Knurled 2 8 Pin Clevis 9 Clip Hairpin 10 Screw Slotted Phillips Washer Head 3 16 24 x 1 2 16 11 Screw Pan Head 5 32 32 x 375 spare 12 Screw Slotted Head 5 32 32 x 75 spare 13 Fuse 1 25A 125V spare 14 Lower Housing Assembly 763746 763746 2 763746 1 15 Glass Shade 762031 762031 762031 16 B...

Страница 20: ...thorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass ...