19
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF880L
8. Wall Control Installation
SINGLE-POLE INSTALLATION
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse or circuit breaker box before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
WARNING
!
CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the Fan, Light Fixture or Receiver.
NOTE: Make all wiring connections using Wire
Connectors (supplied). Make sure that all
connections are tight, including ground, and that no
bare wire is visible at the wire connectors, except
for the ground wire.
8.1
Disconnect electrical power to the Branch Circuit at the
Circuit Breaker or Fuse Box before attempting to install
the Ceiling Fan Wall Control into the Outlet Box.
8.2
Remove Faceplate and Screws from existing Wall
Control. Pull Control out from the Wall Box.
Determine the “hot” Wire and the “load” Wire and
disconnect these Wires from Control (Figure 28).
Do not attempt to disconnect any Wires not already
connected to Existing Control.
EXISTING
WALL CONTROL
HOT
BLK
NEUTRAL
BLACK
GROUND
L
O
A
D
B
L
A
C
K
RECEIVER LOCATED WITHIN
THE CEILING COVER
Figure 28
FACEPLATE
WALL OUTLET BOX
EXISTING SWITCH
SCREWS (2)