background image

Product Data Document

420DS-4c

July 19, 2007 - Page 7

Bristol

®

 ControlWave

®

 LP

Remote Automation Solutions

Website:  www.EmersonProcess.com/Remote

Configuration Wizard simplifies Network setup

Local Configuration Wizard

 allows local commu-

nication with any attached ControlWave controller 

or RTU to download system flashware upgrades, 

configure cold download parameters, and configure 

IP and soft-switch parameters.

DataView for Real-time data display

DataView 

is an on-line utility for ControlWave and 

Network 3000 nodes used to collect and display 

several types of process data, including signal 

values, data array values, signal lists, and audit 

trail information.  Operators have the ability to alter 

signal values. Multiple DataView windows may be 

open simultaneously.

TechTools – OPC Server & ActiveX 

Controls

The Technicians Toolkits consist of a set of configu

-

ration wizards and standard web pages which are 

used to configure a newly installed ControlWave or 

modify those parameters on an existing controller.  

The key components of the Technicians Toolkit are:

WebBSI

- A set of Active X controls allowing commu-

nication access to ControlWave are provided for en-

gineers to develop their own custom web pages us-

ing any standard package such as  Microsoft

®

 Front-

Page. Active X controls allow data to be viewed in 

any compliant container (such as Microsoft Excel 

and Word or Visual Basic), or a compliant web page 

Browser such as Microsoft Internet Explorer.  

Real-time ActiveX Controls

One of the many benefits

 TechTools

 brings to 

you is our use of open standards such as ActiveX 

Controls. AcitveX is another of the Microsoft stan-

dards, which allow plug and play with any ActiveX 

container, using Microsoft ActiveX container tech-

nology such as Visual Basic, HTML web pages, and 

Microsoft Excel

The set of available ActiveX Controls provides the 

basic functions necessary to communicate and col-

lect data from ControlWave.

ActiveX Controls

Security – 56-bit encryption - allows the user to 

sign on to the RTU.
Signal Value – displays signal values in various 

formats.
Comm Statistics – works with a standard 

page that displays the RTU’s communication 

statistics.

Configuration Info – works with a standard page 

that displays and allows the user to change 

RTU Configuration information.

Содержание Bristol ControlWave LP

Страница 1: ...the ControlWave and Network 3000 family of process automation controllers and RTU s The ControlWave LP is compact in size and offers the full programmabil ity of ControlWave Designer IEC 61131 compliant software and communicates via standard BSAP as well as other industry standard protocols The ControlWave LP is available in an open chassis assembly for mounting to a panel or within an enclo sure ...

Страница 2: ...he four I O modules are fixed as follows 16 Discrete Inputs 8 Discrete Outputs 4 High Speed Counters 8 Analog Inputs Two on board Field Power Supplies are provided one for DI and HSC operation and one for AI opera tion The output voltages are electrically isolated 500 VDC and are regulated at 24V Specifications CPU Intel Ultra Low Power 486SX 32 bit processor 25 MHz Data Storage Memory 2 MB SRAM b...

Страница 3: ...o chassis 38 VDC MOV across input signals and input to chassis Meets ANSI IEEE C37 90 1978 Terminations Pluggable maximum wire size is 16 gauge Bus Access 16 Bits Wide ControlWave LP Analog Input Module Number of Points 8 Input Configuration Isolated Voltage Input 1 5V Isolated Current Input 4 20 mA Powered Current Loop 4 20 mA Accuracy 0 1 of span 25 deg C 0 2 of span 20 deg C to 70 deg C 0 3 of ...

Страница 4: ... Accuracy 0 1 of span 25o C 0 2 of span 20 to 70 o C 0 3 of span 40 to 85 o C Common Mode Voltage 500 VDC AO ground to chassis Surge Suppression 16 V Transorb across input to AO Ground Meets ANSI IEEE C37 90 1975 Environmental Specifications Operating Temperature 40o C to 70o C 40o F to 158o F Storage Temperature 40o C to 85o C 40o F to 185o F Relative Humidity 15 95 Noncondensing Vibration 10 150...

Страница 5: ...al OPC Server HistTools Historical Data Collector Scheduler and File Converter By adhering to such industry standards as Ethernet TCP IP Microsoft Windows COM DCOM OLE and Active X ControlWave is able to achieve the highest degree of openness in control system architecture and bring you the optimal process efficiency and productivity you need to ensure a successful system implementation To minimiz...

Страница 6: ...utilities to easily create the OPC server database from the ControlWave application configuration files then provide access to those variables to any OPC compliant HMI product for operator display and interaction with the ControlWave network HistTools Historical collection and storage Communication engine for PC applications Supports ControlWave and Network 3000 serial and IP protocols RS 232 Dial...

Страница 7: ... Technicians Toolkit are WebBSI A set of Active X controls allowing commu nication access to ControlWave are provided for en gineers to develop their own custom web pages us ing any standard package such as Microsoft Front Page Active X controls allow data to be viewed in any compliant container such as Microsoft Excel and Word or Visual Basic or a compliant web page Browser such as Microsoft Inte...

Страница 8: ...ature is the Audit storage and collection system The audit trail is a file stored in ControlWave Flash memory containing significant events and time stamped alarms The alarms stored in the Audit system provide a histori cal archive in addition to the real time alarm report ing system This file is also collected through Open BSI and presented as a text file in the PC This Archive Collection collect...

Страница 9: ...leRTU ControlWave DPC 3335 Operator and Engineering Workstations WAN Plant Automation Management Solution Engineer Customer Serial Modbus ControlWave BSAP Modbus ControlWave Open Network Connectivity By embracing the open system network technolo gies available through TCP IP Ethernet OPC and Microsoft DNA as well as pseudo standards such as Modbus and Open Modbus ControlWave can provide a total Pr...

Страница 10: ... Audit file transfer On line program editing Diagnostics Communication statistics Modbus Modbus is often considered a de facto standard protocol because broad usage as ei ther the primary or a secondary offering in many measurement and control related products Even with its common use Modbus protocol actually has many variations Consider Modbus RTU and Modbus ASCII Master Slave Serial and TCP IP O...

Страница 11: ...ad the ControlWave The Secure Data Advantage ControlWave sets a new standard for providing in telligent control at the point where control is needed Whether you need control on the plant floor or at a remote site in the middle of nowhere ControlWave is the solution for control communication and secure data to help you make the right operating decisions ControlWave was designed to provide the optim...

Отзывы: