![Emerson Bettis RTS FL Series Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/emerson/bettis-rts-fl-series/bettis-rts-fl-series_user-instructions_102090077.webp)
User Instructions
MAN-02-04-60-0352-EN Rev. 3
February 2019
72
Section 12: Maintenance
Maintenance
Section 12: Maintenance
All maintenance work may only be performed with the actuator powered-off.
Due to this
requirement, the actuator has to be in the fail-safe position. If this is not the case, it may be
because of a fault in the fitting (stuck fitting shaft).
CAUTION: OBSERVE SAFETY MEASURES
The actuator has a preloaded disk spring assembly. When loosen the flange mounting
bolts, the spring force against the valve can cause the actuator to come loose from the
valve. Adequate safety measures must be taken.
Any powering up must be ruled out during maintenance. Work on the electrical systems
or components may only be carried out by electricians or by individuals who have been
instructed how to do so. Working under the guidance and supervision of an electrician in
accordance with electrotechnical regulations. After completing their commissioning, the
actuators are ready for use. The actuator is filled with oil as standard when shipped.
Routine checks:
•
Be mindful of increased running noises. In cases of long downtimes, operate the
actuator at least every three months.
•
Check the fail-safe function (check the operating time and smoothness of running
in fail-safe operation). Lengthening in the running time may also be caused by an
increased torque requirement for the fitting after long down times.
CAUTION: ALWAYS REFER TO INSTRUCTIONS
The actuator has a prestressed disk spring assembly. Improper dismounting may lead to
both damage to the actuator as well as serious injuries. If maintenance work is needed
requiring the actuator to be dismounted, contact Emerson regarding detailed instructions
and/or any special purpose tools for relaxing the spring assembly.
The actuators are designed for any mounting position (see Section 3.5), which is why there
is neither a filling level indicator nor a drain plug on the main casing.
Depending on the stressing subjected to, do the following approximately every 10,000 to
20,000 hours (about 5 years; see Section 15):
•
Oil change
•
Replace seals
•
Check all the roller bearings and the worm gear assembly and replace if necessary.
Take the types of oils and greases to be used from our Lubricant Table (see
Section 15
).