![Emerson Bettis RTS FL Series Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/emerson/bettis-rts-fl-series/bettis-rts-fl-series_user-instructions_102090035.webp)
User Instructions
MAN-02-04-60-0352-EN Rev. 3
February 2019
30
Section 6: Commissioning
Commissioning
1.
Loosen but do not remove 4pcs of screws according Figure 8.
2.
Insert 3mm allen key into radial borehole of flange.
3.
Turn flange by use of allen key in direction according Figure 8. Half of possible
rotating angle will approximately double failsafe speed of actuator. While holding
flange with key in desired position retighten screws.
4.
In the version with handwheel reconnect the cable to the cover.
5.
Remount the cover while be aware of correct position of O-ring sealing.
6.
Retest actuator to check for correct failsafespeed.
Figure 34
Adjusting speed
Borehole
Screw
Direction
6.6
Final Step
Following commissioning, ensure covers a sealed and cable inlets are closed. Also, check
the actuator for damaged paint (by transportation or installation) and take necessary steps
to repair if needed.