FRU Installation
AXP 1410 Installation and Use (6806800H70F)
67
SWR1 sets the lower nibble and SWR2 sets the upper nibble. Use a screwdriver to set the
switches by turning them. A little arrow on the switch shows you the value to which the switch
is set.
Figure 4-2
Rotary Switch Location
Two AXP 1410 in the same shelf must always be set to the same SGA. Otherwise, the software
detects that the FRU information in the two AXP 1410s is different and stops the power-up
process. The red LED blinks and the boards are not powered.
Two AXP 1410 in different shelves must always be set to different SGAs. When set to the same
address, both AXP 1410 will start; however, network problems may occur.