TROUBLESHOOTING 

Reset Operation

 

Note:

 When thermostat is reset, installer configuration menu 

settings and programming will reset to factory settings. 
If a voltage spike or static discharge blanks out the display 
or causes erratic thermostat operation, you can reset the 
thermostat by removing the wires from terminals 

and 

(do not short them together) and removing batteries for 2 
minutes. After resetting the thermostat, replace the wires and 
batteries. If the thermostat has been reset and still does not 

function correctly contact your heating/cooling service person 
or place of purchase.  

Note: 

Be sure to review the installer configuration menu 

settings. 
To reset the programming, clock and configuration settings, 
press 

 and 

 and the FAN button simultaneously. The 

thermostat should go blank and then all segments will be 
displayed momentarily.

Symptom

Possible Cause

Correction Action

No Heat/No Cool/No Fan 
(common problems)

1. Blown fuse or tripped circuit breaker. 
2. Furnace power switch to OFF.    
3. Furnace blower compartment door or 

panel loose or not properly installed.

4. Loose connection to thermostat or 

system.

Replace fuse or reset breaker. 
Turn switch to ON. 
Replace door panel in proper position to engage safety 
interlock or door switch. 
Tighten connections.

No Heat

1. Pilot light not lit. 
2. Furnace Lock-Out Condition. Heat 
  may also be intermittent. 
 
 
3. Heating system requires service or 
  thermostat requires replacement. 

Re-light pilot. 
Many furnaces have safety devices that shut down when 
a lock-out condition occurs. If the heat works intermittently 
contact the furnace manufacturer or local HVAC service 
person for assistance. 

Diagnostic: 

Set SYSTEM Switch to 

HEAT 

and raise the 

setpoint above room temperature. Within a few seconds 
the thermostat should make a soft click sound. This sound 
usually indicates the thermostat is operating properly. If 
the thermostat does not click, try the reset operation listed 
above. If the thermostat does not click after being reset 
contact your heating and cooling service person or place 
of purchase for a replacement. If the thermostat clicks, 
contact the furnace manufacturer or a HVAC service 
person to verify the heating is operating correctly.

No Cool

1. Cooling system requires service or 
  thermostat requires replacement. 

Same as diagnostic for No Heat condition except set the 
thermostat to 

COOL

 and lower the setpoint below the room 

temperature. There may be up to a five minute delay before 
the thermostat clicks in Cooling.

 
Heat, Cool or Fan 
Runs Constantly

1. Possible short in wiring. 
2. Possible short in thermostat. 
3. Possible short in heat/cool/fan system. 
4. FAN Switch set to Fan 

ON. 

Check each wire connection to verify they are not shorted 
or touching together. No bare wire should stick out from 
under terminal block. Try resetting the thermostat as 
described above. If the condition persists the manufacturer 
of your system or service person can instruct you on how 
to test the Heat/Cool system for correct operation. If the 
system operates correctly, replace the thermostat.

Thermostat Setting & 
Thermostat Thermometer 
Disagree

1. Thermostat thermometer setting 
  requires adjustment. 

The thermometer can be ad/- 4 degrees. See 
Temperature Display Adjustment in the Configuration Menu 
section.

Furnace (Air Conditioner) 
Cycles Too Fast or Too 
Slow (narrow or wide  
temperature swing)

1. The location of the thermostat and/or 
  the size of the Heating System may 
  be influencing the cycle rate. 

Digital thermostats provide precise control and cycle faster 
than older mechanical models. The system turns on and off 
more frequently but runs for a shorter time so there is no 
increase in energy use. If you would like an increased cycle 
time, choose 

SL

 for slow cycle in the Configuration menu, 

step 6 (heat), 7 (cool) or 8 (heat pump). If an acceptable 
cycle rate is not achieved, contact a local HVAC service 
person for additional suggestions.

Forgot Keypad Lockout 
Code

Hold MENU key for 20 seconds and the lockout will reset.

Содержание 1F83-0422

Страница 1: ...VAC Terminal Load 1 5 A per terminal 2 5A maximum all terminals combined Setpoint Range 45 to 90 F 7 to 32 C Differential Single Stage Heat 0 6 F Cool 1 2 F adjustable Differential Heat Pump Heat 1 2 F Cool 1 2 F adjustable Operating Ambient 32 to 105 F 0 to 41 C Operating Humidity 90 non condensing max Shipping Temperature Range 4 to 150 F 20 to 65 C Dimensions Thermostat 3 7 8 H x 5 1 8 W x 1 1 ...

Страница 2: ...o position To replace the batteries set system to OFF Thermostat can be powered by system AC power or Battery If is displayed the thermostat is battery powered If is not displayed thermostat is system powered with optional battery back up When battery power remaining is approxi mately half the will be displayed When Change is displayed install fresh AA alkaline batteries immediately For best resul...

Страница 3: ...e or clean your filter 4 Displays Set for setpoint when in Run Program mode 5 Displays System Mode Heat Emer Auto Cool Off or Time in menu mode 6 Displays Fan Mode On Auto or Run Sched in Menu mode 7 Displays Run Schedule Schedule or Menu 8 Displays Save when Cool SavingsTM is working 9 Displays Heat Pump when system is configured as Heat Pump thermostat 10 Displays Hold in programmable mode when ...

Страница 4: ... 9 9 MENU Heat Auto Cool Off Heat Cool Off Heat Off with Fan icon Heat Off without Fan icon Cool Off Auto Off System Mode Configuration with Automatic Changeover capability 11 10 10 MENU dL On dL OFF Selects Display Light On or OFF 12 11 11 MENU 0 current temperature 1 HI 2 HI 3 HI 4 HI 1 LO 2 LO 3 LO 4 LO Adjustable Ambient Temperature Display 13 12 12 MENU F C Selects Fahrenheit Celsius Temperat...

Страница 5: ...t range you selected If Save is not displayed and this feature is OFF no change will occur when the cooling system is continu ously running during periods of high demand 5 Energy Management Recovery this step is skipped if configured to be non programmable Energy Manage ment Recovery E On enables the thermostat to start heating or cooling early to make the building temperature reach the program se...

Страница 6: ...ith a 6 set back for night peri ods of both Heat and Cool programs Factory default is On for both When Heat AS On and Cool AS On are activated while in Heat or Cool mode select desired setpoint temperature and press Auto Schedule This value will be copied into all the morning day and evening program periods The night program periods will have a 6 F set back 19 20 Select Fast Second Stage ON or OFF...

Страница 7: ...ge in 15 minute increments 8 After you have set the time and the temperature for the period to begin press SCHEDULE to advance to the next program period 9 Repeat steps 2 through 8 until all of the program times and temperatures are set for all program periods on that day 10 Press SCHEDULE to the next day and repeat steps 2 through 9 11 When programming is complete and all of the times and tempera...

Страница 8: ...y programming see configuration section Factory settings are listed on Monday through Friday Satur day and Sunday If you are re programming a 5 2 day sched ule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a 5 1 1 fill in all lines with the times and temperatures you want Keep the following guidelines in mind when planning you...

Страница 9: ... click try the reset operation listed above If the thermostat does not click after being reset contact your heating and cooling service person or place of purchase for a replacement If the thermostat clicks contact the furnace manufacturer or a HVAC service person to verify the heating is operating correctly No Cool 1 Cooling system requires service or thermostat requires replacement Same as diagn...

Страница 10: ...10 NOTES ...

Страница 11: ...11 NOTES ...

Страница 12: ... www white rodgers com www emersonclimate com Homeowner Help Line 1 800 284 2925 White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co ...

Отзывы: