THERMOSTAT QUICK REFERENCE 

 

Set

SYSTEM

Heat

FAN

        Auto

Menu

Room
Temperature

Setting
Temperature

System
Indicator

Fan
Indicator

Displays the power level of
the 2 “AA” batteries:

    indicates good power level
    indicates batteries at about

half power. “

Change          

” indicates

batteries are low and should be 
replaced with 2 new premium brand 
“AA” Alkaline batteries. 
(See page 2 for more details)

Figure 3 – Home Screen Display

Home Screen Description

Programming and Configuration Items 

1  

“System On”

 indicates when heating or cooling stage 

is energized. 

“System On +2” 

indicates when a second 

stage is energized.

2   The word 

HOLD 

is displayed when the thermostat is in 

the 

HOLD

 mode. 

Temp

 

HOLD

 is displayed when 

the thermostat is in a 

Temporary HOLD

 mode.

3

  Displays 

Change Filter

 when the system has run for 

the programmed filter time period as a reminder to 
change or clean your filter.

4   Displays 

“Set” 

for setpoint when in Run Program mode.

5   Displays 

System Mode (Heat, Emer, Auto, Cool, Off) 

 

or Time in menu mode.

6   Displays 

Fan Mode (On, Auto) 

or 

“Run Sched” 

in  

Menu mode.

7   Displays 

“Run Schedule”

“Schedule”

, or

 “Menu”

.

8

  Displays 

“Save” 

when 

Cool Savings

TM

 

is working.

9   Displays 

“Heat Pump”

 when system is configured 

as Heat Pump thermostat.

10   Displays 

“Hold”

 in programmable mode when not in 

“Hold” 

mode. Displays 

Light Bulb 

in non-programmable 

mode.

11   Initially displays 

“Auto Sched”

. If Auto Schedule had 

been used or disabled, then it displays 

“Cool Savings”

 

when in the 

Cool Mode 

if 

Cool Savings

 has been ena-

bled in the menu.

12  

“Call For Service”

 indicates a fault in the heating/ 

cooling system, it does not indicate a fault in the 
thermostat.

Figure 4 – Programming & Configuration Items

Set

Save

Month Call For Service

Change

Filter

System On     2

SYSTEM

Cool Off Time

Heat Emer Auto

FAN

On Auto

Run Sched

Schedule

Menu

P  Date

Run

Hold

Heat Pump

Temp  Hold

Mo Tu We Th Fr Sa Su

Auto Sched

Cool Savings

Year

11

10

9

1

8

7

6

5

4

3

2

12

Содержание 1F83-0422

Страница 1: ...VAC Terminal Load 1 5 A per terminal 2 5A maximum all terminals combined Setpoint Range 45 to 90 F 7 to 32 C Differential Single Stage Heat 0 6 F Cool 1 2 F adjustable Differential Heat Pump Heat 1 2 F Cool 1 2 F adjustable Operating Ambient 32 to 105 F 0 to 41 C Operating Humidity 90 non condensing max Shipping Temperature Range 4 to 150 F 20 to 65 C Dimensions Thermostat 3 7 8 H x 5 1 8 W x 1 1 ...

Страница 2: ...o position To replace the batteries set system to OFF Thermostat can be powered by system AC power or Battery If is displayed the thermostat is battery powered If is not displayed thermostat is system powered with optional battery back up When battery power remaining is approxi mately half the will be displayed When Change is displayed install fresh AA alkaline batteries immediately For best resul...

Страница 3: ...e or clean your filter 4 Displays Set for setpoint when in Run Program mode 5 Displays System Mode Heat Emer Auto Cool Off or Time in menu mode 6 Displays Fan Mode On Auto or Run Sched in Menu mode 7 Displays Run Schedule Schedule or Menu 8 Displays Save when Cool SavingsTM is working 9 Displays Heat Pump when system is configured as Heat Pump thermostat 10 Displays Hold in programmable mode when ...

Страница 4: ... 9 9 MENU Heat Auto Cool Off Heat Cool Off Heat Off with Fan icon Heat Off without Fan icon Cool Off Auto Off System Mode Configuration with Automatic Changeover capability 11 10 10 MENU dL On dL OFF Selects Display Light On or OFF 12 11 11 MENU 0 current temperature 1 HI 2 HI 3 HI 4 HI 1 LO 2 LO 3 LO 4 LO Adjustable Ambient Temperature Display 13 12 12 MENU F C Selects Fahrenheit Celsius Temperat...

Страница 5: ...t range you selected If Save is not displayed and this feature is OFF no change will occur when the cooling system is continu ously running during periods of high demand 5 Energy Management Recovery this step is skipped if configured to be non programmable Energy Manage ment Recovery E On enables the thermostat to start heating or cooling early to make the building temperature reach the program se...

Страница 6: ...ith a 6 set back for night peri ods of both Heat and Cool programs Factory default is On for both When Heat AS On and Cool AS On are activated while in Heat or Cool mode select desired setpoint temperature and press Auto Schedule This value will be copied into all the morning day and evening program periods The night program periods will have a 6 F set back 19 20 Select Fast Second Stage ON or OFF...

Страница 7: ...ge in 15 minute increments 8 After you have set the time and the temperature for the period to begin press SCHEDULE to advance to the next program period 9 Repeat steps 2 through 8 until all of the program times and temperatures are set for all program periods on that day 10 Press SCHEDULE to the next day and repeat steps 2 through 9 11 When programming is complete and all of the times and tempera...

Страница 8: ...y programming see configuration section Factory settings are listed on Monday through Friday Satur day and Sunday If you are re programming a 5 2 day sched ule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a 5 1 1 fill in all lines with the times and temperatures you want Keep the following guidelines in mind when planning you...

Страница 9: ... click try the reset operation listed above If the thermostat does not click after being reset contact your heating and cooling service person or place of purchase for a replacement If the thermostat clicks contact the furnace manufacturer or a HVAC service person to verify the heating is operating correctly No Cool 1 Cooling system requires service or thermostat requires replacement Same as diagn...

Страница 10: ...10 NOTES ...

Страница 11: ...11 NOTES ...

Страница 12: ... www white rodgers com www emersonclimate com Homeowner Help Line 1 800 284 2925 White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co ...

Отзывы: