PROGRAMMING 

TROUBLESHOOTING 

Comfort Alert Codes

 

The Comfort Alert diagnostics product monitors the air 
conditioning outdoor systems with single phase Copeland 
Scroll compressors. Abnormal system and electrical 
conditions are indicated by flashing ALERT codes on the 
yellow LED on the Comfort Alert module. The flash codes are 
transmitted to the thermostat by the Comfort Alert Thermostat 
interface module. The Comfort Alert compatible thermostat 
displays 

“Call For Service” 

that flashes at the same rate as 

the yellow LED on the Comfort Alert module. 

Comfort Alert Yellow Alert Codes

1 Flash

Long run time

2 Flashs

System pressure trip

3 Flashs

Short cycling

4 Flashs

Locked rotor

5 Flashs

Open circuit

6 Flashs

Open start circuit

7 Flashs

Open run circuit

8 Flashs

Welded Contactor

9 Flashs

Low voltage

Planning Your Program – Important

The Heating and Cooling Program schedules below allow you 
to pencil in your own program times and temperatures.
The 1F85-0422 comes configured for 5/1/1 day programming 
and can also be configured for 5/2 day programming (see 
configuration section).
Factory settings are listed on Monday through Friday, Satur-
day and Sunday. If you are re-programming a 5/2 day sched-
ule, pencil in your own times and temperatures directly below 
the factory times and temperatures.

If you are re-programming a 5+1+1 fill in all lines with the 
times and temperatures you want.
Keep the following guidelines in mind when planning your 
program.
•  In Heating, lower temperatures will save energy.
•  In Cooling, higher temperatures will save energy.
•  If you plan on using Auto Changeover, do not program    

   the heating higher than the cooling.

Worksheet for Re-Programming 5/2 Day and 5+1+1 Day Program

Heating

Program

Wake Up

(Period 1)

Leave For Work

(Period 2)

Return Home

(Period 3)

Go To Bed

(Period 4)

Mon-Fri

6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F

Sat-Sun

or Sat

6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F

Sun

5+1+1 only

6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F

Cooling

Program

Wake Up

(Period 1)

Leave For Work

(Period 2)

Return Home

(Period 3)

Go To Bed

(Period 4)

Mon-Fri

6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F

Sat-Sun

or Sat

6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F

Sun

5+1+1 only

6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F

Содержание 1F83-0422

Страница 1: ...VAC Terminal Load 1 5 A per terminal 2 5A maximum all terminals combined Setpoint Range 45 to 90 F 7 to 32 C Differential Single Stage Heat 0 6 F Cool 1 2 F adjustable Differential Heat Pump Heat 1 2 F Cool 1 2 F adjustable Operating Ambient 32 to 105 F 0 to 41 C Operating Humidity 90 non condensing max Shipping Temperature Range 4 to 150 F 20 to 65 C Dimensions Thermostat 3 7 8 H x 5 1 8 W x 1 1 ...

Страница 2: ...o position To replace the batteries set system to OFF Thermostat can be powered by system AC power or Battery If is displayed the thermostat is battery powered If is not displayed thermostat is system powered with optional battery back up When battery power remaining is approxi mately half the will be displayed When Change is displayed install fresh AA alkaline batteries immediately For best resul...

Страница 3: ...e or clean your filter 4 Displays Set for setpoint when in Run Program mode 5 Displays System Mode Heat Emer Auto Cool Off or Time in menu mode 6 Displays Fan Mode On Auto or Run Sched in Menu mode 7 Displays Run Schedule Schedule or Menu 8 Displays Save when Cool SavingsTM is working 9 Displays Heat Pump when system is configured as Heat Pump thermostat 10 Displays Hold in programmable mode when ...

Страница 4: ... 9 9 MENU Heat Auto Cool Off Heat Cool Off Heat Off with Fan icon Heat Off without Fan icon Cool Off Auto Off System Mode Configuration with Automatic Changeover capability 11 10 10 MENU dL On dL OFF Selects Display Light On or OFF 12 11 11 MENU 0 current temperature 1 HI 2 HI 3 HI 4 HI 1 LO 2 LO 3 LO 4 LO Adjustable Ambient Temperature Display 13 12 12 MENU F C Selects Fahrenheit Celsius Temperat...

Страница 5: ...t range you selected If Save is not displayed and this feature is OFF no change will occur when the cooling system is continu ously running during periods of high demand 5 Energy Management Recovery this step is skipped if configured to be non programmable Energy Manage ment Recovery E On enables the thermostat to start heating or cooling early to make the building temperature reach the program se...

Страница 6: ...ith a 6 set back for night peri ods of both Heat and Cool programs Factory default is On for both When Heat AS On and Cool AS On are activated while in Heat or Cool mode select desired setpoint temperature and press Auto Schedule This value will be copied into all the morning day and evening program periods The night program periods will have a 6 F set back 19 20 Select Fast Second Stage ON or OFF...

Страница 7: ...ge in 15 minute increments 8 After you have set the time and the temperature for the period to begin press SCHEDULE to advance to the next program period 9 Repeat steps 2 through 8 until all of the program times and temperatures are set for all program periods on that day 10 Press SCHEDULE to the next day and repeat steps 2 through 9 11 When programming is complete and all of the times and tempera...

Страница 8: ...y programming see configuration section Factory settings are listed on Monday through Friday Satur day and Sunday If you are re programming a 5 2 day sched ule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a 5 1 1 fill in all lines with the times and temperatures you want Keep the following guidelines in mind when planning you...

Страница 9: ... click try the reset operation listed above If the thermostat does not click after being reset contact your heating and cooling service person or place of purchase for a replacement If the thermostat clicks contact the furnace manufacturer or a HVAC service person to verify the heating is operating correctly No Cool 1 Cooling system requires service or thermostat requires replacement Same as diagn...

Страница 10: ...10 NOTES ...

Страница 11: ...11 NOTES ...

Страница 12: ... www white rodgers com www emersonclimate com Homeowner Help Line 1 800 284 2925 White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co ...

Отзывы: