EES-401 Series Ultrasonic Energy Meter
Revision: 3.0.1
Page 12 of 90
Press
key.
Enter Pipe Material in Window M14.
Press
key.
Enter Fluid Type in Window M20.
Press
key.
Enter Transducer Mounting in Window M24.
Press
key.
Enter to start and stop Manual Totalizer in turn.
Press
key.
Display the Display / Hold Totalizer in turn.
Press
key.
Display Dynamic / Normal Flow Rate and Velocity in
turn.
Press
key.
Enter Fluid Sound Velocity in Window M92.
Press
key
Display Date and Time in Window M60.
Press
key
Press
to start Manual Totalizer, then press
to end Manual Totalizer, press
to input
Standard Totalizer to get the final K factor. Complete
the calibration with pressing
to store.
Press
key
Press
, and enter Zero Cut, the same as Menu 42
Pipe Material [14
0. Carbon Steel
Fluid Type [20
0. Water
Transducer Mounting
0. V
Timing 10 SEC
ON 10.123 m3
Flow 0.1129 m3/h *R
POS 1.1 m3
Flow 0.1129 m3/h Dyn
Vel
1.0415 m/s
Fluid Sound Velocity
1443.4 m/s
YYYY-MM-DD HH:MM:SS
2021-01-09 10:05:06
Manual Calibrate
Press Ent When Ready
Set Zero [42
Press ENT When Ready