18
Probe modules connection
At the top of the motherboard there are 4 adaptors for the installation of the probe modules and inputs.
Upon request, these modules are installed by the manufacturer. For proper installation, check the installed modules and
implement the required connections. A standard Ethernet cable (RJ45) is required for the ETHERNET version (module
with red circle).
Ch1 Ch2 Ch3 Ch4 Ch5
pH or ORP probe
input module*
Adaptor: supplied BNC
*as specified when ordered
Flow sensor
module (mA)
Block 1 : red wire (+)
Block 2 : black wire (-)
Danger
Unplug power
cable from main
power supply
before operate
Connection:
Bl. 1 : (+12) Brown
Bl. 2 : (-12) White
Bl. 3 : (V out) Green
Bl. 4 : (GND) Yellow
MDPH Ch2
MDMA Ch4
1 2
MDRH Ch2
DIOXIDE
SENSOR Ch5
1 2 3 4
Cl probe
connection:
ECL2/2
ECL2/20
ECL17/10
ECL18/10
Jumpers: 5 and 6 open
Block 1 : (+) Brown
Block 2 : (-) White
Block 3 : (IN) Green
Block 4 : (GND) Yellow
ECL4
ECL5
ECL6
ECL7
Jumpers 5 and 6 closed
Block 3 : (-) Black
Block 4 : (+) Red
MDCL Ch3
1 2 3 4
5
6
1 2 3 4
MD
CL485INT
MDSCL Ch3
Cl probe conn.:
SCLxx
1 (-485) GREEN wire
2 (+485) WHITE wire
3 (GND) BLACK wire
4 (+5VDC) RED wire