25
Serial/Ethernet Communication (SCOM) Interface
IND100084-14
MCC Command
Syntax and Functionality
Details and Values
HUE Control
Note:
In video mode only
Not available on STD units
Syntax : 07 FF 4D 43 43 03 23
84
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
84
35 30
16
Query "?" : 07 FF 4D 43 43 02 24
84
3F
3C
Reset "R" : 07 FF 4D 43 43 02 24
84
52
29
Reset "r" : 07 FF 4D 43 43 02 24
84
72
09
Increase "+" : 07 FF 4D 43 43 02 24
84
2B
50
Decrease "-" : 07 FF 4D 43 43 02 24
84
2D
4E
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
Manual Phase Control
Note:
Dot clock (for RGB mode only)
Syntax : 07 FF 4D 43 43 03 23
85
xx yy
zz
Function Examples:
Example "3F" : 07 FF 4D 43 43 03 23
85
33 46
01
Query "?" : 07 FF 4D 43 43 02 24
85
3F
3B
Reset "R" : 07 FF 4D 43 43 02 24
85
52
28
Reset "r" : 07 FF 4D 43 43 02 24
85
52
08
Increase "+" : 07 FF 4D 43 43 02 24
85
2B
4F
Decrease "-" : 07 FF 4D 43 43 02 24
85
2D
4D
Where
xx
= "0" to "3"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "3" "F"
Image Horizontal Position
Syntax : 07 FF 4D 43 43 03 23
86
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
86
35 30
14
Query "?" : 07 FF 4D 43 43 02 24
86
3F
3A
Reset "R" : 07 FF 4D 43 43 02 24
86
52
27
Reset "r" : 07 FF 4D 43 43 02 24
86
72
07
Increase "+" : 07 FF 4D 43 43 02 24
86
2B
4E
Decrease "-" : 07 FF 4D 43 43 02 24
86
2D
4C
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
Note: If Value > 100 then Value=100
Image Vertical Position
Syntax : 07 FF 4D 43 43 03 23
87
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
87
35 30
13
Query "?" : 07 FF 4D 43 43 02 24
87
3F
39
Reset "R" : 07 FF 4D 43 43 02 24
87
52
26
Reset "r" : 07 FF 4D 43 43 02 24
87
72
06
Increase "+" : 07 FF 4D 43 43 02 24
87
2B
4D
Decrease "-" : 07 FF 4D 43 43 02 24
87
2D
4B
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
Note: If Value > 100 then Value=100
Auto Source
Syntax : 07 FF 4D 43 43 02 24
88
xx
zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24
88
31
46
Query "?" : 07 FF 4D 43 43 02 24
88
3F
38
Reset "R" : 07 FF 4D 43 43 02 24
88
52
25
Reset "r" : 07 FF 4D 43 43 02 24
88
72
05
Where
xx
= "0" to "1"
Where
zz
= Calculated Checksum
Available functions:
"0" = Disable
"1" = Enable (default)
OSD Mode
Syntax : 07 FF 4D 43 43 02 24
89
xx
zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24
89
31
45
Query "?" : 07 FF 4D 43 43 02 24
89
3F
37
Reset "R" : 07 FF 4D 43 43 02 24
89
52
24
Reset "r" : 07 FF 4D 43 43 02 24
89
72
04
Where
xx
= "0" to "1"
Where
zz
= Calculated Checksum
Available functions:
"0" = Full (default)
"1" = Simple
Sharpness
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 03 23
8A
xx yy
zz
Function Examples:
Example "07" : 07 FF 4D 43 43 03 23
8A
30 37
0E
Query "?" : 07 FF 4D 43 43 02 24
8A
3F
36
Reset "R" : 07 FF 4D 43 43 02 24
8A
52
23
Reset "r" : 07 FF 4D 43 43 02 24
8A
72
03
Increase "+" : 07 FF 4D 43 43 02 24
8A
2B
4A
Decrease "-" : 07 FF 4D 43 43 02 24
8A
2D
48
Where
xx
= "0" to "F"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "F" "F"
Default: "0" "7"
Manual Frequency Control
Note:
PC mode only.
Syntax : 07 FF 4D 43 43 03 23
8B
xx yy
zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23
8B
35 30
0F
Query "?" : 07 FF 4D 43 43 02 24
8B
3F
35
Increase "+" : 07 FF 4D 43 43 02 24
8B
2B
49
Decrease "-" : 07 FF 4D 43 43 02 24
8B
2D
47
Where
xx
= "0" to "6"
Where
yy
= "0" to "F"
Where
zz
= Calculated Checksum
Max Range: "0" "0" to "6" "4"
Содержание HATTELAND TECHNOLOGY SCOM X Series
Страница 36: ...36 This page left intentionally blank...
Страница 37: ...37 Appendixes...
Страница 46: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...