32
Serial/Ethernet Communication (SCOM) Interface
IND100084-14
MCC Command
Syntax and Functionality
Details and Values
Load User Default
Note:
Available function list differs
between MMD and STD units!
Syntax : 07 FF 4D 43 43 02 24
D8
xx
zz
Function Examples:
Example "3" : 07 FF 4D 43 43 02 24
D8
33
F4
Where
xx
= "1" to "5"
Where
zz
= Calculated Checksum
Available functions (MMD):
"0" = Read Defaults
"1" = User1 Slot
"2" = User2 Slot
"3" = User3 Slot
"4" = User4 Slot
"5" = User5 Slot
Available functions (STD):
"0" = Read Defaults
"1" = User Slot
Available response status:
"0" = Fail
"1" = Successful
Swap Main & Second Source
Note:
Not available on STD units.
Send Only : 07 FF 4D 43 43 01 25
E3
1C
Available response status:
"0" = Fail
"1" = Successful
Gamma Reset
Note:
A power off/on to the unit is
required to reboot the internal
display code. This can either be
done by issue the "Power down
/ up" command described earlier
in this table or do a physical
power off/on for the unit.
Send Only : 07 FF 4D 43 43 01 25
E5
1A
Available response status:
"0" = Fail
"1" = Successful
GDC Menu Button
Send Only : 07 FF 4D 43 43 01 25
F7
08
Physical Button press equivalent
GDC ">" (down) Button
Send Only : 07 FF 4D 43 43 01 25
FA
05
Physical Button press equivalent
GDC "<" (up) Button
Send Only : 07 FF 4D 43 43 01 25
FB
04
Physical Button press equivalent
GDC "+" (right) Button
Send Only : 07 FF 4D 43 43 01 25
FC
03
Physical Button press equivalent
GDC "-" (left) Button
Send Only : 07 FF 4D 43 43 01 25
FD
02
Physical Button press equivalent
RS Address (extended)
Syntax : 07 FF 4D 43 43 02 24 7D
xx
yy
zz
Function Examples:
"address 254" : 07 FF 4D 43 43 02 24 7D
FE
84
Query "?" : 07 FF 4D 43 43 02 24 7D
FF
3F
44
Reset "R" : 07 FF 4D 43 43 02 24 7D
FF
52
31
Reset "r" : 07 FF 4D 43 43 02 24 7D
FF
72
11
*[1] - See comment
Where
xx
= 0x00 - 0xFF
Where
yy
= Query/Reset byte, only
when
xx
= 0xFF. Otherwise skip.
Where
zz
= Calculated checksum
See next page for "?", "R/r", "+" and "-" command descriptions.
*[1] RS Address (extended):
The command is extended command Address configuration of RS485 configuration. It provides the same
function as MCC 0xBB, but with two differences:
- Extended command MCC 0x7D is able to set address from 0x00 to 0xFE
- Extended command data byte in heximal format.
This command update the same data byte in EEPROM and OSD status package as MCC 0x7D.