Specifications - Isolated Digital Input/Output Module
PCA100297-1
32
IND100129-169
All specifications are subject to change without prior notice!
SPECIFICATIONS
Note: All specifi cations are subject to change without prior notice!
Please visit www.hatteland-display.com for the latest electronic version.
2/2
Supported Operating Systems (OS)
Embedded Enterprise (WEE):
- Microsoft® Windows® Server 2003/2008/2008R2 (Eng)
- Microsoft® Windows® 2003/2008/2008R2 (Eng)
- Microsoft® Windows® 7 Professional/Ultimate (Eng, SP1)
- Windows® 10 IoT Enterprise 2016 LTSB
Linux:
- openSUSE® 11.4
- Fedora™ 15
- Ubuntu® 10.04 LTS
- Ubuntu® 12.04 LTS
Note: Listed Operating Systems above are hardware/platform dependent. Please check datasheet for speci
c unit if OS is supported.
Currently supported D2XX Drivers
Processor Architecture
Operating System (OS)
Release Date
(yyyy-mm-dd)
x86 (32-bit)
x64 (64-bit)
Comments [Footnote]
Microsoft® Windows®*
2013-02-20
2.08.28
2.08.28
2.08.28 WHQL Certified [*1]
Release Notes [*2]
Linux
2012-06-29
1.1.12
1.1.12
[*3]
*includes the following versions of the Microsoft® Windows® operating systems:
Windows® XP, Windows® Server 2003, Windows® Vista, Windows® Server 2008, Windows® 7, Windows® Server 2008 R2 and Windows® 8.
For updates, please visit:
http://www.ftdichip.com/Drivers/D2XX.htm
Footnotes:
[*1] =
http://www.ftdichip.com/Drivers/CDM/CDM20828_Setup.exe
[*2] =
http://www.ftdichip.com/Drivers/CDM/CDM%202%2008%2030%20Release%20Info%20for%208.1.rtf
[*3] =
http://www.ftdichip.com/Drivers/D2XX/Linux/ReadMe-linux.txt
Getting started, documentation and specific Hatteland Display Library links:
http://www.ftdichip.com/Support/Documents/ProgramGuides/D2XX_Programmer%27s_Guide(FT_000071).pdf
http://www.hatteland-display.com/pdf/misc/doc101781-1_programmer_guide_ht00273opt-a1.pdf
http://www.hatteland-display.com/drivers/dio_pca100297-1_ht00273opt-a1_package.zip
Additional
• Cable connector
(MC 1,5/ 5-STF-3,81) Terminal Block 3.81 (see illustration below)
• Test and certi
cate
Hatteland Display standard, (tested / type approved by the following classification societies):
IEC 60945 4th
(EN 60945:2002),
IACS E10
,
EU RO MR
- Mutual Recognition
• Safety IEC60950
The DIO module is intended to be used in control circuits and does therefore need external fuse to meet
safety agency approvals.
Illustration and Pinning
Note: Product below for illustration only. Location of module and product size/design may differ. Connector/pinning/specifications remain the same.
5-pin Terminal Block 3.81
Module A Module B
Module A Module B
A1 External Power +
A1
IN+[0]
A2 N/C (Not Connected)
A2
IN-[0]
B1 External Power - (GND1)
B1
IN+[1]
B2 N/C (Not Connected)
B2
IN-[1]
O1 HS[0]
O1 N/C
C1 HS[1]
C1 IN+[2]
C2 N/C (Not Connected)
C2 IN-[2]
D1 HS[2]
D1 IN+[3]
D2 N/C (Not Connected)
D2 IN-[3]
O2 HS[3]
O2 N/C
Содержание Hatteland Display HT B22G Series
Страница 6: ...6 This page left intentionally blank...
Страница 7: ...7 General...
Страница 11: ...11 Installation...
Страница 24: ...24 This page left intentionally blank...
Страница 25: ...25 Specifications...
Страница 37: ...37 Technical Drawings...
Страница 39: ...39 Technical Drawings Accessories...
Страница 44: ...44 This page left intentionally blank...
Страница 45: ...45 Appendixes...
Страница 65: ...65 Appendix IND100077 24 User Notes...
Страница 67: ...67 Revision History IND100077 128...
Страница 68: ...www hatteland display com...