Model Specifications

 

Model:  HI05V08Y1 

 

HS05V08Y1 (with noise suppression)

 

Motor: 230 V (+ or - 10%) ~ 60 Hz, Single Phase

 

No-load motor speed: 1750 rpm

 

Power: 5 HP

 

2 stage, 3 cylinder, cast-iron piston pump

 

Max. pressure: 155 psi

 

No-load pump speed: 790 rpm

 

Pump oil capacity: 2 quarts (1.9 liters) 

 

Air delivery:  

18 cfm @ 100 psi 

16.5 cfm @ 155 psi

 

Tank size: 80 gal. (302.8 L)

 

Tank outlet: 3/4"

 

Weight-  HI05V08Y1: 485 lb. (220 kg) 

 

HS05V08Y1: 558 lb. (253 kg)

 

Complies with CCR462 (L)(2).

Contents

Model Specifications ………………………… 2
Inspection ………………………………………… 3
Description ……………………………………… 3

Get to know your compressor …………………3

Safety Information …………………………… 4
Basic Guidelines ……………………………… 5

Breathable Air ………………………………………5
Pressurized Components ………………………5
Personal Protective Equipment ………………5

Installation ……………………………………… 6

Area ……………………………………………………6
Electrical Safety ……………………………………6

Operation ………………………………………… 7

Safety Rules …………………………………………7
Air Tool Cautions …………………………………7

Getting Started  ………………………………… 8
Power Source Connection ………………… 8

Power Requirements ……………………………8
Grounding Instructions …………………………8

Assembly ………………………………………… 8
Operation  ………………………………………… 8

Before operating your air compressor:  …8

General Overview ……………………………… 9

Installation and Location ………………………9
Air Intake ……………………………………………9
Pipe Connection ……………………………………9

Starting  …………………………………………… 10

Pressure Switch ……………………………………10
Adjusting the air pressure ……………………10
Shutting off your compressor …………………10
Cold Weather Starting ……………………………10

Maintenance  …………………………………… 10

Service …………………………………………………10
Daily  ……………………………………………………11
Weekly …………………………………………………11
Monthly ………………………………………………11

Troubleshooting ……………………………… 11

Slow Pumping Or Insufficient Pressure  …11
Overheating …………………………………………12
Storage …………………………………………………12

Troubleshooting Chart ……………………… 13
Hulk Warranty Statement ………………… 14

READ INSTRUCTION MANUAL BEFORE OPERATING. 

In order to receive maximum performance and long life from your compressor, the following instructions 

should be read carefully and all points regarding installation and operation of the unit should be noted and 

observed. Carefully reading this manual before connecting anything to the motor or compressor is necessary 

for optimum trouble-free operation.

 

Содержание 815002014265

Страница 1: ...ucts for safe operation However operators and maintenance per sons are responsible for maintaining safety All safety precautions are included to provide a guideline for minimizing the possibility of a...

Страница 2: ...s 7 Getting Started 8 Power Source Connection 8 Power Requirements 8 Grounding Instructions 8 Assembly 8 Operation 8 Before operating your air compressor 8 General Overview 9 Installation and Location...

Страница 3: ...Description Get to know your compressor Please refer to fig 1 and 2 1 TANK DRAIN VALVE located on bottom of tank The tank drain valve can be opened to allow moisture and compressed air to be released...

Страница 4: ...surized 11 MOTOR 12 CONNECTION BOX A place to make connection to electrical power for the air compressor 13 MOTOR WIRING BOX AND CAPACITORS Vary the connection to electrical power for the air compress...

Страница 5: ...s used for the purpose of breathing air application and proper in line safety and alarm equipment is not simultaneously used existing warranties are void and EMAX Air Force Technology disclaims any li...

Страница 6: ...erhead to avoid condensation dripping on compressor which could cause rust and or motor shorting Electrical Safety Be sure only trained and authorized personnel maintain this compressor in accordance...

Страница 7: ...tection Compressor starts automatically Moving parts Do not touch Keep guards in place Compressor does not supply breathable air Keep all persons away from the discharge opening of hoses or tools or o...

Страница 8: ...ed to a circuit protected by fuses use time delay fuse marked D Installation should be executed by a licensed electrician who should verify the ACTUAL VOLTAGE of the circuit into which the tool will b...

Страница 9: ...a firm level surface Unless the base is exactly level shims will probably be required Any space between base and foot should be shimmed rather than drawing the foot down thus placing strain on the un...

Страница 10: ...pplied to the piping system To increase or decrease air pressure turn air regulator knob in the direction indicated by the manufacturer Use an outlet pressure gauge not supplied mounted downstream fro...

Страница 11: ...belts so the motor cannot start up unexpectedly When belt tension is adjusted properly the belts can be depressed at a point midway between the motor pulley and the flywheel approximately one half in...

Страница 12: ...rt in intercooler fins or cylinder fins blow out with air 6 Poor ventilation and ambient temperature is too high where the compressor is stored Storage When storing your compressor 1 Be sure the unit...

Страница 13: ...has engaged due to motor overheat ing 1 Check that the main supplied voltage corresponds to the compres sor specifications An inadequate extension cord too thin or too long can cause the motor to over...

Страница 14: ...will be provided online once you enter the required information Choose the new SMART OIL maintenance kit option to extend your Hulk by EMAX air compressor pump up to 8 years of coverage SMART OIL not...

Отзывы: