background image

4

HULK Power

4

of excessive pressure build up. The safety valve 

is preset at factory. Do not attempt to make any 

adjustments to the safety valve. Periodically pull 

the ring on the safety valve end to check that it 

is working properly. 

5. 

RESERVOIR AIR PRESSURE GAUGE - 

Indicates pressure of compressed air built up in 

the tank.

6. 

PRESSURE SWITCH - 

Turns the air compressor on and off and will 

start the compressor pump automatically when 

tank pressure is below the factory-set minimum. 

The pressure switch continues to monitor the 

pressure and turns the pump off when the 

pressure reaches the factory-set maximum.

Always make sure that the 

compressor power is in the OFF 

position before performing any maintenance or 

plugging the compressor into a power supply.

7. 

 AIR FILTERS - 

Ensures the air being pressurized is free of 

contaminants and reduces the amount of noise 

the pump generates.  

Air filters are mounted in Whisper 100 (19, fig.2), 

on units that have the Whisper Silencer.

8. 

PUMP OUTPUT AIR TUBE - 

Conducts the compressed air to the tank as it 

leaves the compressor pump.

9. 

SIGHT GAUGE -  

Allows easy viewing of your air compressor 

pump's oil level.

10. 

PUMP CYLINDER -  

Where the air is pressurized.

11. 

MOTOR

12. 

CONNECTION BOX - 

A place to make connection to electrical power 

for the air compressor.

13. 

MOTOR WIRING BOX AND CAPACITORS- 

Vary the connection to electrical power for the 

air compressor.

14. 

BELT AND PULLEY GUARD

15. 

DRIVEN PUMP PULLEY / FAN

16. 

DRIVE PULLEY

17. 

TANK (PRESSURE VESSEL) ASME/CRN 

CERTIFICATION PLATE

18. 

MOUNTING BRACKET FOR "WHISPER" NOISE 

SUPPRESSION SYSTEM. 

19. 

"WHISPER" NOISE SUPPRESSION SYSTEM 

mounted (HS05V080Y1- fig 2). Houses air 

pre-filters and compressor air filters, which 

require routine maintenance.

fig 2

19

20. 

TANK ACCESS PLUG

21. 

TANK OUTLET WITH BALL VALVE SHUT-OFF

Safety Information

This manual contains very important information to 

know and understand. This is provided for SAFETY 

and to PREVENT EQUIPMENT PROBLEMS. To help 

understand this information, observe the following:

Danger indicates an imminently 

hazardous situation which, if not 

avoided, will result in death or serious injury.

Warning indicates a potentially 

hazardous situation which, if not 

avoided, could result in death or serious injury.

Caution indicates a potentially 

hazardous situation which, if not 

avoided, may result in minor or moderate injury.

Notice indicates important 

information, that if not followed, may 

cause damage to equipment.

  Read all manuals included with this 

product carefully. Be thoroughly 

familiar with the controls and the 

proper use of the equipment.

 

 

 

MANUAL

Содержание 815002014265

Страница 1: ...ucts for safe operation However operators and maintenance per sons are responsible for maintaining safety All safety precautions are included to provide a guideline for minimizing the possibility of a...

Страница 2: ...s 7 Getting Started 8 Power Source Connection 8 Power Requirements 8 Grounding Instructions 8 Assembly 8 Operation 8 Before operating your air compressor 8 General Overview 9 Installation and Location...

Страница 3: ...Description Get to know your compressor Please refer to fig 1 and 2 1 TANK DRAIN VALVE located on bottom of tank The tank drain valve can be opened to allow moisture and compressed air to be released...

Страница 4: ...surized 11 MOTOR 12 CONNECTION BOX A place to make connection to electrical power for the air compressor 13 MOTOR WIRING BOX AND CAPACITORS Vary the connection to electrical power for the air compress...

Страница 5: ...s used for the purpose of breathing air application and proper in line safety and alarm equipment is not simultaneously used existing warranties are void and EMAX Air Force Technology disclaims any li...

Страница 6: ...erhead to avoid condensation dripping on compressor which could cause rust and or motor shorting Electrical Safety Be sure only trained and authorized personnel maintain this compressor in accordance...

Страница 7: ...tection Compressor starts automatically Moving parts Do not touch Keep guards in place Compressor does not supply breathable air Keep all persons away from the discharge opening of hoses or tools or o...

Страница 8: ...ed to a circuit protected by fuses use time delay fuse marked D Installation should be executed by a licensed electrician who should verify the ACTUAL VOLTAGE of the circuit into which the tool will b...

Страница 9: ...a firm level surface Unless the base is exactly level shims will probably be required Any space between base and foot should be shimmed rather than drawing the foot down thus placing strain on the un...

Страница 10: ...pplied to the piping system To increase or decrease air pressure turn air regulator knob in the direction indicated by the manufacturer Use an outlet pressure gauge not supplied mounted downstream fro...

Страница 11: ...belts so the motor cannot start up unexpectedly When belt tension is adjusted properly the belts can be depressed at a point midway between the motor pulley and the flywheel approximately one half in...

Страница 12: ...rt in intercooler fins or cylinder fins blow out with air 6 Poor ventilation and ambient temperature is too high where the compressor is stored Storage When storing your compressor 1 Be sure the unit...

Страница 13: ...has engaged due to motor overheat ing 1 Check that the main supplied voltage corresponds to the compres sor specifications An inadequate extension cord too thin or too long can cause the motor to over...

Страница 14: ...will be provided online once you enter the required information Choose the new SMART OIL maintenance kit option to extend your Hulk by EMAX air compressor pump up to 8 years of coverage SMART OIL not...