background image

10

HULK Power

4.  Insert the power supply cord into the power 

supply socket. 

5.  Turn the pressure switch on, moving the lever 

to the AUTO position (fi g 8.1).

6.  On the reservoir pressure gauge, you can 

watch pressure build in the tank until the pump 

stops at the factory-set pressure, about 115 to 

125 psi.

7. 

This fi rst time running your compressor and 

periodically thereafter, check for air leaks. If 

the gauge indicates pressure is going down in 

the tank or you hear leakage, you could apply 

soapy water to all joints in the air transport 

piping. Tighten these joints if bubbles form.

Adjusting the air pressure

Your air compressor is supplied with an air pressure 

regulator. This regulator adjusts the air pressure 

supplied to the hose.

• 

To increase air pressure, turn air regulator 

knob (fi g 9.10) clockwise.

• 

To decrease air pressure, turn air regulator 

knob counterclockwise.

•  Use the outlet pressure gauge (fi g 9.8) to see 

the resulting pressure.

Shutting off your compressor

1. Move the pressure switch clockwise to the OFF 

position (fi g 8.0).

2. Unplug the compressor from the electical power.
3. If not draining the tank, reduce tank pressure 

through the air hose.

1

0

fig 8

10

8

fig 9

4. Drain the tank by slowly opening the drain valve 

(fi g 7.1). Place a catch basin under the valve to 

protect the surface from water damage.

Cold Weather Starting

Temperatures below freezing (32 °F / 0 °C) cause 

the metal parts of your air compressor to contract 

and that makes starting more diffi  cult. To assist the 

air compressor in starting in cold weather, follow 

these tips:

1. Try to keep the air compressor stored in 

temperatures above 32 °F (0 °C).

2. Open the air tank drain valve and release all air 

pressure from the air tank before attempting to 

start in cold weather. (After air is released from air 

tank, close drain valve.)

3. Pull the ring on the safety valve before each use 

to make sure the valve is functional.

4. Plug the air compressor directly into a 120 

volt electrical outlet. Do not use an extension 

cord when starting your air compressor in cold 

weather.

Maintenance 

Daily 

 

Before each use, 

1.  check for any unusual noise or vibration.
2.  be sure all nuts and bolts are tight.

 

After each use, drain condensation from the air 

tank.

Monthly

 

Inspect air system for leaks by applying soapy 

water to all joints. Tighten these joints if leaks 

are discovered.

Storage

When storing your compressor:

1. Be sure the unit is turned OFF.
2. Unplug it from power source.
3. Rotate the regulator to set the outlet pressure to 

zero.

4. Release air pressure from all hoses and air 

tank(s).

5. Drain all moisture from air tank(s).
6. Fully close drain valve(s).
7. Protect electrical cord and air hoses from damage 

(such as being stepped on or driven over). Wrap 

all cords and hoses loosely around the (cooled) 

air compressor.

8. Place air compressor in a cool, dry, safe, and 

indoor location. 

Содержание 815002014005

Страница 1: ...ufactures products for safe operation However operators and maintenance per sons are responsible for maintaining safety All safety precautions are included to provide a guideline for minimizing the po...

Страница 2: ...ion 5 Area 5 Electrical Safety 6 Operation 6 Safety Rules 6 Air Tool Cautions 7 Power Source Connection 8 Power Requirements 8 Grounding Instructions 8 Connect to power source 8 Getting Started 8 Asse...

Страница 3: ...ttempt to make any adjustments to the safety valve Periodically pull the ring on the safety valve end to check that it is working properly 5 RESERVOIR AIR PRESSURE GAUGE Indicates pressure of compress...

Страница 4: ...MENT PROBLEMS To help understand this information observe the following Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury Warning indicates...

Страница 5: ...r other modifications Such modifications may weaken the air tank and cause a hazardous condition 5 If the air tank develops a leak replace it immediately Never repair weld or make modifications to the...

Страница 6: ...with three pin plug it should be plugged into a three pin electrical socket Never remove the ground pin 10 Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators T...

Страница 7: ...s damage to equipment or personal injury could result from excessive air pressure 20 Compressed air from the unit may contain carbon monoxide Air produced is not suitable for breathing purposes 21 Alw...

Страница 8: ...ian before proceeding Connect to power source Consult a qualified electrician for proper installation of receptacle at the source of power This tool must be grounded while in use to protect the operat...

Страница 9: ...the proper circuit size can eliminate nuisance circuit breaker tripping while operating your air compressor Extension Cords For optimum air compressor performance an extension cord should not be used...

Страница 10: ...e Cold Weather Starting Temperatures below freezing 32 F 0 C cause the metal parts of your air compressor to contract and that makes starting more difficult To assist the air compressor in starting in...

Страница 11: ...e un loader valve plug and clean the valve seal If damaged replace seal and re install Compressor stopped and will not re start 1 Thermal overload protector has engaged due to motor overheat ing 1 Che...

Страница 12: ...r 2 31 Self tapping screw 4 32 Fan 2 33 Outside spring 2 34 Crank throw 2 35 Stator 1 36 Rotor 1 37 Bearing 2 38 Outside spring 2 No Description Qty 39 Pad 2 40 Plastic head cover 2 41 Capacitor cover...

Страница 13: ...13 HP02P010SS man v 171212 Air Compressor Schematic Drawing 40 74 40 75...

Страница 14: ...nty does not apply to defects due directly or indirectly to misuse abuse negligence or accidents repairs or alterations and lack of maintenance HULK shall not be liable for death injuries to persons o...

Страница 15: ...nt s curitaire Cependant les op rateurs et les personnes charg es de l entretien sont responsables du maintien de la s curit Toutes les pr cautions de s curit sont incluses pour fournir une ligne dire...

Страница 16: ...ne 20 S curit lectrique 20 Op ration 21 R gles de s curit 21 Pr cautions sur l outil pneumatique 22 Alimentation de la source 22 Exigences d alimentation 22 Instructions de mise la terre 23 Raccordeme...

Страница 17: ...atiquement la pression du r servoir d air en cas de compression excessive La soupape de s curit est pr r gl e en usine N essayez pas d effectuer des r glages sur la soupape de s curit Retirez p riodiq...

Страница 18: ...le sens des aiguilles d une montre pour augmenter la pression d air dans le sens inverse des aiguilles d une montre pour diminuer la pression d air 11 R CUP RATEUR D AIR Le raccord rapide en laiton p...

Страница 19: ...MANUAL AVERTISSEMENT DANGER PAS d charger l air de ces syst mes dans des zones non ventil es ou autres Composants sous pression 1 Cet quipement est fourni avec un r cipient sous pression con ue ASME...

Страница 20: ...emp rature qui passent au dessus pour viter que la condensation ne d goutte sur le compresseur ce qui pourrait ATTENTION AVERTISSEMENT DANGER provoquer de la rouille et ou un court circuit du moteur S...

Страница 21: ...ventilateur ou d autres dispositifs de protection retir s 6 NE PAS chahuter avec les tuyaux d air car des blessures graves ou m me la mort ATTENTION peuvent en r sulter 7 Assurez vous d avoir une vent...

Страница 22: ...du compresseur S lectionner outils pneumatiques tuyaux d air tuyaux soupapes filtres et autres accessoires en cons quence NE PAS d passer les pressions de fonctionnement s res class es du fabricant po...

Страница 23: ...ur d air comme dans la position 7 fig 1 ci dessus 1 Enfilez le filtre air dans l orifice de la t te du moteur situ sous le car nage en plastique 2 Vissez soigneusement le filtre air fig 2 7 dans la cu...

Страница 24: ...s le compresseur et une surchauffe S lectionnez une rallonge correctement mise la terre qui s accouple directement avec la prise de courant et le cordon d alimentation du compresseur sans utiliser d a...

Страница 25: ...ur d marrer par temps froid suivez ces 10 8 fig 9 conseils 1 Essayez de conserver le compresseur d air des temp ratures sup rieures 0 C 32 F 2 Ouvrez la soupape de vidange du r servoir d air et rel ch...

Страница 26: ...rez la fiche de la soupape du d chargeur et nettoyez le joint de soupape Si endommag remplacez le joint et r installez Le compresseur s est arr t et ne veux pas repartir 1 Le protecteur de surcharge t...

Страница 27: ...rvoir a une capacit r duite en raison de la r tention d eau 2 Le pressostat est hors r glage 1 Ouvrir le robinet de vidange pour lib rer de l eau 2 Contactez le support la client le L unit de pompe ne...

Страница 28: ...3 Ressort ext rieur 2 34 Coude de vilebrequin 2 35 Stator 1 36 Rotor 1 37 Roulement 2 38 Ressort ext rieur 2 No Description Qt 39 Entretoise 2 40 Couvercle de t te en plastique 2 41 Couvercle du conde...

Страница 29: ...29 HP02P010SS man v 171212 HULK Power Dessin sch matique 40 74 40 75...

Страница 30: ...caus s directement ou indirectement par une mauvaise utilisation un abus une n gligence ou des accidents des r parations ou des modifications et le manque de maintenance HULK ne sera pas responsable...

Страница 31: ...31 HP02P010SS man v 171212 HULK Power...

Страница 32: ...32 Compresseur air...

Отзывы: