background image

7

HP02P010SS man v.171212

Air Compressor

8. 

When checking or when refilling air line anti-

icer systems with antifreeze compound, shut 

off compressor and allow it to cool. Keep 

sparks, flames and other ignition sources 

away and DO NOT permit smoking in the 

vicinity.

9.  Stop compressor and disconnect power if a 

hazardous condition arises.

10. 

Wear snug fitting clothing and confine long 

hair when around compressor. Keep all body 

parts and clothing away from couplings, 

flywheel and other moving parts of the 

equipment.

Keep all persons away from the 

discharge opening of hoses or 

tools or other points of 

compressed air discharge. If the 

machine is installed in an 

enclosed area, be sure to vent 

the relief valve outside of the structure or to an 

unoccupied area.

Always make sure main power is 

off before touching moving parts 

of compressor.

11.  Never exceed the pressure rating of any 

component in system.

12.  Protect material and air lines from damage or 

puncture. Keep hose and power cable away 

from sharp objects, moisture, chemicals, oil, 

etc.

13.  Check condition of hoses before each use.  

Do not use a damaged hose. If hose is 

damaged, replace immediately.

14.  Read, understand and comply with all warning 

labels on unit.

15. Drain tank of moisture after each use.  

If compressor is not to be used for extended 

periods of time, leave tank drain valve open to 

allow moisture to completely drain from tank.

16.  Do not tamper with Safety Valve. The 

Safety Valve is factory set for your model air 

compressor. Any user adjustments to Safety 

Valve will automatically void warranty.

17.  Air compressors get hot while in operation. 

NEVER touch the motor, the 

discharge tubing or compressor 

pump while in operation.

18. 

The compressor turns itself on and off 

automatically while the pressure switch is 

turned on.

19. The air pressure switch is set at the factory  

for optimum performance of your equipment. 

Never attempt to bypass or remove this switch 

as serious damage to equipment or personal 

injury could result from excessive air pressure.

 

 

20.  Compressed air from the unit may contain 

carbon monoxide. Air produced is not suitable 

for breathing purposes.

21.  Always use a respirator when spraying paint 

or chemicals.

Air Tool Cautions

1.  DO NOT use air tools that are rated below the 

maximum rating of the compressor. Select 

air tools, air hoses, pipes, valves, filters and 

other fittings accordingly. DO NOT exceed 

manufacturer’s rated safe operating pressures 

for these items.

2.  Make sure all hose connections are 

adequately secured to prevent tools or hose 

ends from being accidentally disconnected.

3.  Remove adjusting keys or wrenches before 

turning the tool on. A wrench or key that is 

left attached to a moving part of the tool may 

result in personal injury.

4.   Keep work area clean and well lit.  

Cluttered or dark work areas invite accidents.

5.   Keep children away.  

All children should be kept away from the work 

area. Never let a child handle a tool without 

strict adult supervision.

6.   Store idle tools out of the reach of children and 

untrained persons.  

Tools may be dangerous in the hands of 

untrained users.

7. 

Do not operate any tool if under the influence 

of alcohol or drugs.  

Read warning labels on prescriptions to 

determine if your judgment or reflexes are 

impaired while taking drugs. If there is any 

doubt, do not attempt to operate.

8.    Do not force tool.  

Use the correct tool for your application. The 

correct tool will do the job better and safer at 

the rate for which it was designed.

9.   Do not use the tool if the switch does not turn 

it on and off. 

 

Any tool that cannot be controlled with the 

switch is dangerous and must be repaired.

10.  Check for damage.  

Check your tool regularly. If part of the tool 

is damaged it should be carefully inspected 

to make sure that it can perform its’ intended 

function correctly. If in doubt, the part should 

be repaired. Refer all servicing to a qualified 

technician. Consult your dealer for advice.

11.  Maintain tools with care.  

Keep tools sharp and clean. Properly 

maintained tools, with sharp cutting edges, are 

less likely to bind and are easier to control.

Содержание 815002014005

Страница 1: ...ufactures products for safe operation However operators and maintenance per sons are responsible for maintaining safety All safety precautions are included to provide a guideline for minimizing the po...

Страница 2: ...ion 5 Area 5 Electrical Safety 6 Operation 6 Safety Rules 6 Air Tool Cautions 7 Power Source Connection 8 Power Requirements 8 Grounding Instructions 8 Connect to power source 8 Getting Started 8 Asse...

Страница 3: ...ttempt to make any adjustments to the safety valve Periodically pull the ring on the safety valve end to check that it is working properly 5 RESERVOIR AIR PRESSURE GAUGE Indicates pressure of compress...

Страница 4: ...MENT PROBLEMS To help understand this information observe the following Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury Warning indicates...

Страница 5: ...r other modifications Such modifications may weaken the air tank and cause a hazardous condition 5 If the air tank develops a leak replace it immediately Never repair weld or make modifications to the...

Страница 6: ...with three pin plug it should be plugged into a three pin electrical socket Never remove the ground pin 10 Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators T...

Страница 7: ...s damage to equipment or personal injury could result from excessive air pressure 20 Compressed air from the unit may contain carbon monoxide Air produced is not suitable for breathing purposes 21 Alw...

Страница 8: ...ian before proceeding Connect to power source Consult a qualified electrician for proper installation of receptacle at the source of power This tool must be grounded while in use to protect the operat...

Страница 9: ...the proper circuit size can eliminate nuisance circuit breaker tripping while operating your air compressor Extension Cords For optimum air compressor performance an extension cord should not be used...

Страница 10: ...e Cold Weather Starting Temperatures below freezing 32 F 0 C cause the metal parts of your air compressor to contract and that makes starting more difficult To assist the air compressor in starting in...

Страница 11: ...e un loader valve plug and clean the valve seal If damaged replace seal and re install Compressor stopped and will not re start 1 Thermal overload protector has engaged due to motor overheat ing 1 Che...

Страница 12: ...r 2 31 Self tapping screw 4 32 Fan 2 33 Outside spring 2 34 Crank throw 2 35 Stator 1 36 Rotor 1 37 Bearing 2 38 Outside spring 2 No Description Qty 39 Pad 2 40 Plastic head cover 2 41 Capacitor cover...

Страница 13: ...13 HP02P010SS man v 171212 Air Compressor Schematic Drawing 40 74 40 75...

Страница 14: ...nty does not apply to defects due directly or indirectly to misuse abuse negligence or accidents repairs or alterations and lack of maintenance HULK shall not be liable for death injuries to persons o...

Страница 15: ...nt s curitaire Cependant les op rateurs et les personnes charg es de l entretien sont responsables du maintien de la s curit Toutes les pr cautions de s curit sont incluses pour fournir une ligne dire...

Страница 16: ...ne 20 S curit lectrique 20 Op ration 21 R gles de s curit 21 Pr cautions sur l outil pneumatique 22 Alimentation de la source 22 Exigences d alimentation 22 Instructions de mise la terre 23 Raccordeme...

Страница 17: ...atiquement la pression du r servoir d air en cas de compression excessive La soupape de s curit est pr r gl e en usine N essayez pas d effectuer des r glages sur la soupape de s curit Retirez p riodiq...

Страница 18: ...le sens des aiguilles d une montre pour augmenter la pression d air dans le sens inverse des aiguilles d une montre pour diminuer la pression d air 11 R CUP RATEUR D AIR Le raccord rapide en laiton p...

Страница 19: ...MANUAL AVERTISSEMENT DANGER PAS d charger l air de ces syst mes dans des zones non ventil es ou autres Composants sous pression 1 Cet quipement est fourni avec un r cipient sous pression con ue ASME...

Страница 20: ...emp rature qui passent au dessus pour viter que la condensation ne d goutte sur le compresseur ce qui pourrait ATTENTION AVERTISSEMENT DANGER provoquer de la rouille et ou un court circuit du moteur S...

Страница 21: ...ventilateur ou d autres dispositifs de protection retir s 6 NE PAS chahuter avec les tuyaux d air car des blessures graves ou m me la mort ATTENTION peuvent en r sulter 7 Assurez vous d avoir une vent...

Страница 22: ...du compresseur S lectionner outils pneumatiques tuyaux d air tuyaux soupapes filtres et autres accessoires en cons quence NE PAS d passer les pressions de fonctionnement s res class es du fabricant po...

Страница 23: ...ur d air comme dans la position 7 fig 1 ci dessus 1 Enfilez le filtre air dans l orifice de la t te du moteur situ sous le car nage en plastique 2 Vissez soigneusement le filtre air fig 2 7 dans la cu...

Страница 24: ...s le compresseur et une surchauffe S lectionnez une rallonge correctement mise la terre qui s accouple directement avec la prise de courant et le cordon d alimentation du compresseur sans utiliser d a...

Страница 25: ...ur d marrer par temps froid suivez ces 10 8 fig 9 conseils 1 Essayez de conserver le compresseur d air des temp ratures sup rieures 0 C 32 F 2 Ouvrez la soupape de vidange du r servoir d air et rel ch...

Страница 26: ...rez la fiche de la soupape du d chargeur et nettoyez le joint de soupape Si endommag remplacez le joint et r installez Le compresseur s est arr t et ne veux pas repartir 1 Le protecteur de surcharge t...

Страница 27: ...rvoir a une capacit r duite en raison de la r tention d eau 2 Le pressostat est hors r glage 1 Ouvrir le robinet de vidange pour lib rer de l eau 2 Contactez le support la client le L unit de pompe ne...

Страница 28: ...3 Ressort ext rieur 2 34 Coude de vilebrequin 2 35 Stator 1 36 Rotor 1 37 Roulement 2 38 Ressort ext rieur 2 No Description Qt 39 Entretoise 2 40 Couvercle de t te en plastique 2 41 Couvercle du conde...

Страница 29: ...29 HP02P010SS man v 171212 HULK Power Dessin sch matique 40 74 40 75...

Страница 30: ...caus s directement ou indirectement par une mauvaise utilisation un abus une n gligence ou des accidents des r parations ou des modifications et le manque de maintenance HULK ne sera pas responsable...

Страница 31: ...31 HP02P010SS man v 171212 HULK Power...

Страница 32: ...32 Compresseur air...

Отзывы: