background image

6

HULK Power

3.  Use shims to level compressor if installation 

area is not flat. This will avoid excessive 

vibration and premature pump wear.

DO NOT install compressor in  

boiler room, paint spray room, or 

area where sandblasting occurs. Make sure inlet 

air is away from exhaust fumes or other toxic, 

noxious or corrosive fumes or substances.

4.  If acid is used in operating environment or air 

is dust laden, pipe intake to outside, fresh air. 

Increase pipe size by one size for every 20 

feet of run. Be sure to install protective hood 

around intake filter.

5.  Insulate cold water or other low temperature 

pipes that pass overhead to avoid 

condensation dripping on compressor which 

could cause rust and/or motor shorting.

Electrical Safety

Be sure only trained and 

authorized personnel maintain 

this compressor in accordance 

with all applicable federal, state 

and local codes, standards and 

regulations. Follow all NEC 

(National Electric Code) standards especially 

those concerning equipment grounding 

conductors.

1.  Follow all NEC and local codes for electrical 

wiring. Allow only authorized Polar Air service 

person or certified electrician to install 

electrical components.

2.  Put unit on dedicated circuit and make sure 

no other electrical equipment is wired into it. 

Failure to wire unit on independent circuit can 

cause circuit overload and/or imbalance in 

motor phasing. Install proper No Fuse Breaker 

(NFB) according to kW output of compressor.

3.  Ensure incoming service has adequate 

ampere rating.

4.  Ensure supply line has the same electrical 

characteristics (voltage, cycles and phase) as 

the electric motor.

5.  Refer to amp load information on the 

specifications label and use correctly sized 

wiring. Be sure to consider distance between 

power supply and machine.

6.  Install surge protection device between power 

supply and compressor motor.

7.  Make sure to install properly sized breakers 

and fuses.

8.  The unit must be properly grounded. DO NOT 

connect ground wire to air or cooling lines. 

9.  If the tool is equipped with three-pin plug, it 

should be plugged into a three-pin electrical 

socket. Never remove the ground pin.

10. Avoid body contact with grounded surfaces 

such as pipes, radiators, ranges, and 

 

 

refrigerators. There is an increased risk of 

electric shock if your body is grounded.

11. To reduce the risk of electrical shock or injury, 

do not expose tool to moisture.  

Don’t use this tool in damp or wet locations. 

Keep out of rain.

12. Do not abuse cord.  

Never use the cord to carry tools or pull the 

plug from an outlet. Keep cord away from 

heat, sharp edges or moving parts. Check 

for damage and replace damaged cords 

immediately before connecting to power 

supply. Damaged cords increase the risk of 

electric shock.

13. Always disconnect the tool from power source 

before making any adjustments, storing, 

servicing, or changing accessories. Such 

preventative safety measures reduce the risk 

of starting the tool accidentally.

14. 

Keep away from flammables. 

 

Do not attempt to operate this tool near 

flammable materials or combustibles. Failure 

to comply may cause serious injury or death.

15. Risk of Fire or Explosion.  

Do not spray flammable liquid in a confined 

area. Spray area must be well ventilated. 

Do not smoke while spraying or spray where 

spark or flame is present. Keep compressors 

as far from spraying area as possible.

Operation

Safety Rules

1.  Make sure all operators receive product 

training, read and understand all instructions.

Keep all flammable, combustible, 

poisonous and noxious materials 

away from operating area. Make 

sure there are no oily rags, trash, 

leaves, litter or other 

combustible materials in 

operating area. Keep suitable, fully charged fire 

extinguishers nearby when servicing and 

operating the compressor.

2. 

NEVER allow modifications to compressor 

structure or controls.

3.  Keep all ignition sources away from exposed 

electrical parts.

4.  Keep all persons clear of compressor during 

start-up and operation.

5.  NEVER operate the compressor with the fan, 

coupling or other guards removed.

6.  DO NOT engage in horseplay with air hoses 

as death or serious injury may result.

7.  Make sure to provide adequate ventilation 

while operating the compressor. If combustible 

substances are spilled, clean up immediately.

 

Содержание 815002014005

Страница 1: ...ufactures products for safe operation However operators and maintenance per sons are responsible for maintaining safety All safety precautions are included to provide a guideline for minimizing the po...

Страница 2: ...ion 5 Area 5 Electrical Safety 6 Operation 6 Safety Rules 6 Air Tool Cautions 7 Power Source Connection 8 Power Requirements 8 Grounding Instructions 8 Connect to power source 8 Getting Started 8 Asse...

Страница 3: ...ttempt to make any adjustments to the safety valve Periodically pull the ring on the safety valve end to check that it is working properly 5 RESERVOIR AIR PRESSURE GAUGE Indicates pressure of compress...

Страница 4: ...MENT PROBLEMS To help understand this information observe the following Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury Warning indicates...

Страница 5: ...r other modifications Such modifications may weaken the air tank and cause a hazardous condition 5 If the air tank develops a leak replace it immediately Never repair weld or make modifications to the...

Страница 6: ...with three pin plug it should be plugged into a three pin electrical socket Never remove the ground pin 10 Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators T...

Страница 7: ...s damage to equipment or personal injury could result from excessive air pressure 20 Compressed air from the unit may contain carbon monoxide Air produced is not suitable for breathing purposes 21 Alw...

Страница 8: ...ian before proceeding Connect to power source Consult a qualified electrician for proper installation of receptacle at the source of power This tool must be grounded while in use to protect the operat...

Страница 9: ...the proper circuit size can eliminate nuisance circuit breaker tripping while operating your air compressor Extension Cords For optimum air compressor performance an extension cord should not be used...

Страница 10: ...e Cold Weather Starting Temperatures below freezing 32 F 0 C cause the metal parts of your air compressor to contract and that makes starting more difficult To assist the air compressor in starting in...

Страница 11: ...e un loader valve plug and clean the valve seal If damaged replace seal and re install Compressor stopped and will not re start 1 Thermal overload protector has engaged due to motor overheat ing 1 Che...

Страница 12: ...r 2 31 Self tapping screw 4 32 Fan 2 33 Outside spring 2 34 Crank throw 2 35 Stator 1 36 Rotor 1 37 Bearing 2 38 Outside spring 2 No Description Qty 39 Pad 2 40 Plastic head cover 2 41 Capacitor cover...

Страница 13: ...13 HP02P010SS man v 171212 Air Compressor Schematic Drawing 40 74 40 75...

Страница 14: ...nty does not apply to defects due directly or indirectly to misuse abuse negligence or accidents repairs or alterations and lack of maintenance HULK shall not be liable for death injuries to persons o...

Страница 15: ...nt s curitaire Cependant les op rateurs et les personnes charg es de l entretien sont responsables du maintien de la s curit Toutes les pr cautions de s curit sont incluses pour fournir une ligne dire...

Страница 16: ...ne 20 S curit lectrique 20 Op ration 21 R gles de s curit 21 Pr cautions sur l outil pneumatique 22 Alimentation de la source 22 Exigences d alimentation 22 Instructions de mise la terre 23 Raccordeme...

Страница 17: ...atiquement la pression du r servoir d air en cas de compression excessive La soupape de s curit est pr r gl e en usine N essayez pas d effectuer des r glages sur la soupape de s curit Retirez p riodiq...

Страница 18: ...le sens des aiguilles d une montre pour augmenter la pression d air dans le sens inverse des aiguilles d une montre pour diminuer la pression d air 11 R CUP RATEUR D AIR Le raccord rapide en laiton p...

Страница 19: ...MANUAL AVERTISSEMENT DANGER PAS d charger l air de ces syst mes dans des zones non ventil es ou autres Composants sous pression 1 Cet quipement est fourni avec un r cipient sous pression con ue ASME...

Страница 20: ...emp rature qui passent au dessus pour viter que la condensation ne d goutte sur le compresseur ce qui pourrait ATTENTION AVERTISSEMENT DANGER provoquer de la rouille et ou un court circuit du moteur S...

Страница 21: ...ventilateur ou d autres dispositifs de protection retir s 6 NE PAS chahuter avec les tuyaux d air car des blessures graves ou m me la mort ATTENTION peuvent en r sulter 7 Assurez vous d avoir une vent...

Страница 22: ...du compresseur S lectionner outils pneumatiques tuyaux d air tuyaux soupapes filtres et autres accessoires en cons quence NE PAS d passer les pressions de fonctionnement s res class es du fabricant po...

Страница 23: ...ur d air comme dans la position 7 fig 1 ci dessus 1 Enfilez le filtre air dans l orifice de la t te du moteur situ sous le car nage en plastique 2 Vissez soigneusement le filtre air fig 2 7 dans la cu...

Страница 24: ...s le compresseur et une surchauffe S lectionnez une rallonge correctement mise la terre qui s accouple directement avec la prise de courant et le cordon d alimentation du compresseur sans utiliser d a...

Страница 25: ...ur d marrer par temps froid suivez ces 10 8 fig 9 conseils 1 Essayez de conserver le compresseur d air des temp ratures sup rieures 0 C 32 F 2 Ouvrez la soupape de vidange du r servoir d air et rel ch...

Страница 26: ...rez la fiche de la soupape du d chargeur et nettoyez le joint de soupape Si endommag remplacez le joint et r installez Le compresseur s est arr t et ne veux pas repartir 1 Le protecteur de surcharge t...

Страница 27: ...rvoir a une capacit r duite en raison de la r tention d eau 2 Le pressostat est hors r glage 1 Ouvrir le robinet de vidange pour lib rer de l eau 2 Contactez le support la client le L unit de pompe ne...

Страница 28: ...3 Ressort ext rieur 2 34 Coude de vilebrequin 2 35 Stator 1 36 Rotor 1 37 Roulement 2 38 Ressort ext rieur 2 No Description Qt 39 Entretoise 2 40 Couvercle de t te en plastique 2 41 Couvercle du conde...

Страница 29: ...29 HP02P010SS man v 171212 HULK Power Dessin sch matique 40 74 40 75...

Страница 30: ...caus s directement ou indirectement par une mauvaise utilisation un abus une n gligence ou des accidents des r parations ou des modifications et le manque de maintenance HULK ne sera pas responsable...

Страница 31: ...31 HP02P010SS man v 171212 HULK Power...

Страница 32: ...32 Compresseur air...

Отзывы: