INSTALLATION P8
Note: The pump suction and discharge connections are mounded in
thread stops, DO NOT tr y to screw the pipe beyond these stops.
SB and SR series pump has 2 sets 2” union adaptor in internal and external
thread and universal design for metric and imperial PVC pipe connection.
5.2 ELECTRICAL WIRING
Warning:
This power pump demand licensed or certified electrician or
qualified pool installer to ensure there is adequate protection between
the pump motor and mains power supply according to individual countries
safety code.
The pump has power cord with plug attached on the plug, plug it to a
power socket with circuit breaker to isolate the motor from the mains
power for over load protection. The circuit breaker rating should refer to the electrical specification of
individual pump working voltage and power.
The power has to be with a Residual Current Device (RCD) or Ground Fault Circuit Interrupt (GFCI) having a rated
residual operating current not exceeding 30mA.
If the RCD / GFCI device trips, it means there is fault on the power line or motor. Do not use
this pump. Disconnect the pump and have the problem corrected by a qualified ser vice
representative before using. Press the reset button to reset the RDC / GFCI devices after
fixed. It will keeps the circuit shut off and will not reset if the power line problem is not
fixed.
It is recommend to test the RCD / GFCI at least once a month.
MIN
5
X
SUCTION
PIPE
DIAMETER
Recommended Piping
ELBOW
Veritcal lift
no more than 3m(10ft)
Pumps should be shipped with Power cord with plug for corresponding countries. If there is not power cord
attached to the pump, it is necessar y to follow the local electricity power line color code to connect the power
according to the wiring for individual pump diagram.
5.3 ELECTRICAL WIRING– 3 PHASE
For pump operate at 380Vac or above, 3 phase power line is needed to drive the motor. The latest cable color
code is Brown for L1, Black for L2, Grey for L3 , Blue for Neutral and Green & Yellow for Earth.
For old code it is Red for L1, Yellow for L2, Blue for L3, Black for Neutral and Green & Yellow for Earth.