emaux SB & SR Series Скачать руководство пользователя страница 15

REPLACEMENT PARTS    P14

Key No.

Part No.

Description

QTY

20

20

20

20

20

20

20

20

20

20

20

20

20

20

21

22

23

23

24

25

26

26

27

27

28

28

29

29

29

29

29

30

30

30

30

31

32

89021303A

89021304

89021401

89021402

89021403

89021404

89021601

89021602

89021603

89021604

89021501

89021502

89021503

89021504

89021310

01021021

01111032

01111031

89021312

89021505

01031001

01031002

01031008

01031009

01031007

01031006

04016014

04016015

04016016

04016022

04016023

04015042

04015015

04015012

04016037

02021039

04014018

Motor SB/ SR20 (220V/50Hz)

Motor SB/ SR30 (220V/50Hz)

Motor SB/ SR10 (220V/60Hz)

Motor SB/ SR15 (220V/60Hz)

Motor SB/ SR20 (220V/60Hz)

Motor SB/ SR30 (220V/60Hz)

Motor SB/ SR10 (380V/50Hz)

Motor SB/ SR15 (380V/50Hz)

Motor SB/ SR20 (380V/50Hz)

Motor SB/ SR30 (380V/50Hz)

Motor SB/ SR10 (110V/60Hz)

Motor SB/ SR15 (110V/60Hz)

Motor SB/ SR20 (110V/60Hz)

Motor SB/ SR30 (110V/60Hz)

M8*20 Bolt for motor with washer

Opening key

Base with Nut & Washer for SB10/ Sb15

Base with Nut & Washer for SB20/ Sb30

Cable Box for SB/ SR Pump 220V/50Hz; 220V/60Hz; 380V/50Hz.

Cable Box for SB/ SR Pump 110V/60Hz

Fan Cover for EPH SB/SR20 SB/SR30

Fan Cover for SB/SR10,SB/SR15 Pump

Fan Cover for SB/SR20,SB/SR30 Pump

Fan Cover for SB/SR10,SB/SR15 Pump

Cooling fan for SC SB/SR10,SB/SR15

Cooling fan for EPH SB/SR20,SB/SR30

Capacitor for SB/ SR10/ SB/ SR15 (220V/50Hz) (220V/60Hz)

Capacitor for SB/ SR20 (220V/50Hz) (220V/60Hz)

Capacitor for SB/ SR30 (220V/50Hz) (220V/60Hz)

Capacitor for SB/ SR10/ SB15 (110V/60Hz)

Capacitor for SB/ SR20/ SB30 (110V/60Hz)

Overload Switch PE77-6A/250VAC for SB/ Sr10

Overload Switch PE77-8A/250VAC for SB/ Sr15

Overload Switch PE77-10A/250VAC for SB/ Sr20

Overload Switch PE77-13A/250VAC for SB/ Sr30

Cover for Overload Switch

Insulation Fitting for Overload Switch

1

1

1

1

1

1

1

1

1

1

1

1

1

1

4

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Note: 6* 89280103B is 2.0 Union in Black Colour

           6* 89280103W is 2.0 Union in White Colour

Содержание SB & SR Series

Страница 1: ...USER MANUAL SB SR Series Centrifugal Pump Installation and Operation Manual Model SB SR Series SAA gepr fte Sicherheit SASO EMPU21061901...

Страница 2: ...T 1 SB AND SR SERIES CENTRIFUGAL PUMP OVERVIEW 2 PRODUCT INFORMATION SB SERIES 3 PRODUCT INFORMATION SR SERIES 4 IMPORTANT SAFETY INSTRUCTIONS 5 INSTALLATION 5 1 PIPING 7 5 2 ELECTRICAL WIRING 5 3 ELE...

Страница 3: ...iping and conduit within 1 5 m 5 ft of inside walls of swimming pool spa or hot tub 5 Never open the inside of the drive motor enclosure There is a capacitor bank that holds a mains supply voltage cha...

Страница 4: ...a single submerged suction outlet shall use a suction outlet cover that meets ASME ANSI A112 19 8a and either 1 A SVRS meeting ASME ANSI A112 19 17 and or ASTM F2387 or 2 A properly designed and test...

Страница 5: ...380Vac electrical power is available 2 PRODUCT INFORMATION SB SERIES Model 50Hz Input kW Current AMP Noise dB Head m 6 8 10 12 14 16 FlowRate m h SB10 SB15 SB20 0 97 1 30 1 80 4 7 8 2 5 9 67 69 67 16...

Страница 6: ...3905 SR10 2 63mm 1 0hp Horsepower Weight kg 14 70 88023607 88023608 88023707 88023708 88023907 88023908 SR15 SR20 2 63mm 2 63mm 1 5hp 2 0hp 16 30 19 70 SR30 2 18 10 5 69 32 30 5 28 25 21 88023609 8802...

Страница 7: ...ser must read the instructions before beginning installation and start up Keep this manual for future reference 4 IMPORTANT SAFETY INSTRUCTIONS DIMENSIONS PERFORMANCE CURVE 275 144 413 557 20 40 60 80...

Страница 8: ...3 The appliance shall be installed in accordance with national wiring regulations means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules A disconnected i...

Страница 9: ...ating current not exceeding 30mA If the RCD GFCI device trips it means there is fault on the power line or motor Do not use this pump Disconnect the pump and have the problem corrected by a qualified...

Страница 10: ...n and status monitoring 3 Protection relay is an overload thermal protection device 4 Single phase MCB for secondary protection DOL Starter can be applied to motor connect in Delta or WYE Star connect...

Страница 11: ...all piping of construction debris and verify that the piping has passed a proper pressure test 2 Check the filter and other equipment for proper installation verifying all clamps and connections are p...

Страница 12: ...g groove on the pre filter body and replace the Lid To help keep the Lid from sticking tighten it by hand only 6 Put back the basket with opening face directly to the suction inlet as the picture show...

Страница 13: ...ires replacement Low pump capacity 1 Valve in the suction or discharge line partly closed 2 Suction or discharge line partly plugged 3 Suction or discharge line too small 4 Plugged basket in skimmer o...

Страница 14: ...ng for Lid Basket Pre Filter Body 2 0 Union Black White Colour Drain Plug with O ring Square Gasket M6 x 30 Screw for Pump Body Pump body for SB SR Screw for Impeller with O Ring O Ring for Diffuser D...

Страница 15: ...60Hz M8 20 Bolt for motor with washer Opening key Base with Nut Washer for SB10 Sb15 Base with Nut Washer for SB20 Sb30 Cable Box for SB SR Pump 220V 50Hz 220V 60Hz 380V 50Hz Cable Box for SB SR Pump...

Страница 16: ...Impeller SR20 110V 60Hz 220V 60Hz Impeller SR20 220V 50Hz 380V 50Hz Impeller SR10 220V 50Hz and 380V 50Hz SR15 110V 60Hz and 220V 60Hz Impeller SR15 220V 50Hz and 380V 50Hz SR30 110V 60Hz and 220V 60H...

Страница 17: ...ucts free from defects in materials and workmanship under normal use during warranty period The warranty period begins on the day of purchase and extends only to the original purchaser It is not trans...

Страница 18: ...STRIVE FOR CLEAR WATER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD...

Отзывы: