![emaux SB & SR Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/emaux/sb-and-sr-series/sb-and-sr-series_installation-and-operation-manual_2399304011.webp)
START UP P10
6. START UP
1. Verify the pump shaft turn freely.
2. Check the mains voltage, current and frequency are accordingly to the name plate.
3. Never run pump dr y! Running pump dr y may cause damage to the mechanical seal causing
leakage and flooding. Fill the pre-filter with water before starting motor.
4. Before removing the pre-filter Lid, STOP PUMP, CLOSE GATE VALVES in suction and discharge
pipes.
5. Always STOP THE PUMP before when RELEASE ALL PRESSURE from the pump and the piping system before
proceeding.
6. Never tighten or loosen screw while the pump is in operation.
7. The suction pipe and the suction inlet in the pool must be free from obstruction.
Before start-up, the alignment of the pump should be checked. The tubing should be inspected to ensure that they
are properly fitted and tightened and that they do not exert pressure or tension on the pump's suction or discharge
connection. The pump should never be operated.
Wiring Box Diagram:
SB10, SB15,SB20, SB30, SR10, SR15, SR20. SR30 all model 220Vac 50/60Hz.
Circuit
Breaker
Ground
Capacitor Holder
Capacitor
L
N
WARNING: Tighten/untighten the pump Lid by hand only.
1. Clear all piping of construction debris and verify that the piping has passed a proper pressure test.
2. Check the filter and other equipment for proper installation, verifying all clamps and connections are properly
installed as per the manufacturer's instructions.
3. Open any shut off valves on the suction and discharge lines.
4. Open the filter pressure relief valve and release all pressure from the system.
5. If the pump is located below the water level of the pool, opening the pressure relief valve will fill the pump with
water.
6. If the pump is located above the pool water level, remove the Lid from the pre-filter and fill with water before
starting the pump.
7. Check to see that the Lid O-ring and seat areas are clean and lubricated. Debris in the sealing area can cause air
to leak into the system and make it difficult to prime the pump.
8. Close / tighten the Lid to make an airtight seal.
9. Turn on power wait for pump to prime. Pump priming time for 3m (10ft) should be at least 4.5 minutes. Priming
will depend on vertical length of suction lift and horizontal length of suction pipe. If pump does not prime within
prime time, stop the motor and determine cause.
10. If the pump does not prime within 10 minutes. Ensure all instructions to this point have been followed. Stop the
pump! Check for suction leaks and repeat steps (1) through (8).