P7    INSTALLATION

5. INSTALLATION

Correct disposal of this product

This  symbol  on  the  product,  or  in  its  packaging,  indicates  that  this 

product  may  not  be  treated  as  household  waste.  Instead,  it  should 

be taken to the appropriate waste collection point for the recycling 

of  electrical  and  electronic  equipment.  By  ensuring  this  product  is 

disposed  of  correctly,  you  will  help  prevent  potential  negative 

consequences  for  the  environment  and  human  health,  which  could 

other wise  be  caused  by  the  inappropriate  waste  handling  of  this 

product.  For  more  detailed  information  about  the  recycling  of  this 

product,  please  contact  your  local  council,  your  household  waste 

disposal ser vice, or the shop where you purchased the product.

5.1 PIPING

1. A protective device is to be installed in the fixed wiring.

2. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensor y 

or  mental  capabilities  or  lack  of  experience  and  knowledge  if  they  have  been  given  super vision  or  instruction 

concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with 

the appliance. Cleaning and user maintenance shall not be made by children without super vision.

3. The appliance shall be installed in accordance with national wiring regulations means for disconnection must be 

incorporated  in  the  fixed  wiring  in  accordance  with  the  wiring  rules.  A  disconnected  incorporated  in  the  fixed 

wiring is to be provided.

4.  The  pump  is  to  be  supplied  through  a  residual  current  device  (RCD)  or  Ground  Fault  Circuit  Interrupt  (GFCI) 

having a rated residual operation current not exceeding 30mA. 

1.  Install  the  pump  as  close  to  the  pool  as  possible,  preferably  in  a  dr y,  well  ventilated  area  away  from  direct  sun 

light. Protect the pump from excessive moisture.

2. Place the pump as close to the water source as possible, so that the suction pipe is short, straight and direct to 

reduce  the  friction  loss.  Don't  install  the  pump  at  more  than  10  ft  (3  meters)  of  geometrical  height  from  water 

level.

3. Before installing the pump, make sure that the surface is solid, elevated, rigid and vibration free.

4. Secure the pump to the base with screws or bolts to limit the vibration and the stress on the pipe or the joints.

5. Leave enough space for gate valves in suction and discharge piping, if required.

6. Ensure there is enough clearance for pre-filter basket & Lid open and motor ventilation.

7. Connect the suction and discharge pipe to the outlet and inlet of the swimming pool.

8. Make sure that floor drainage is adequate to prevent flooding.

9. Make sure that the pump and piping are accessible for ser vicing.

Содержание SB & SR Series

Страница 1: ...USER MANUAL SB SR Series Centrifugal Pump Installation and Operation Manual Model SB SR Series SAA gepr fte Sicherheit SASO EMPU21061901...

Страница 2: ...T 1 SB AND SR SERIES CENTRIFUGAL PUMP OVERVIEW 2 PRODUCT INFORMATION SB SERIES 3 PRODUCT INFORMATION SR SERIES 4 IMPORTANT SAFETY INSTRUCTIONS 5 INSTALLATION 5 1 PIPING 7 5 2 ELECTRICAL WIRING 5 3 ELE...

Страница 3: ...iping and conduit within 1 5 m 5 ft of inside walls of swimming pool spa or hot tub 5 Never open the inside of the drive motor enclosure There is a capacitor bank that holds a mains supply voltage cha...

Страница 4: ...a single submerged suction outlet shall use a suction outlet cover that meets ASME ANSI A112 19 8a and either 1 A SVRS meeting ASME ANSI A112 19 17 and or ASTM F2387 or 2 A properly designed and test...

Страница 5: ...380Vac electrical power is available 2 PRODUCT INFORMATION SB SERIES Model 50Hz Input kW Current AMP Noise dB Head m 6 8 10 12 14 16 FlowRate m h SB10 SB15 SB20 0 97 1 30 1 80 4 7 8 2 5 9 67 69 67 16...

Страница 6: ...3905 SR10 2 63mm 1 0hp Horsepower Weight kg 14 70 88023607 88023608 88023707 88023708 88023907 88023908 SR15 SR20 2 63mm 2 63mm 1 5hp 2 0hp 16 30 19 70 SR30 2 18 10 5 69 32 30 5 28 25 21 88023609 8802...

Страница 7: ...ser must read the instructions before beginning installation and start up Keep this manual for future reference 4 IMPORTANT SAFETY INSTRUCTIONS DIMENSIONS PERFORMANCE CURVE 275 144 413 557 20 40 60 80...

Страница 8: ...3 The appliance shall be installed in accordance with national wiring regulations means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules A disconnected i...

Страница 9: ...ating current not exceeding 30mA If the RCD GFCI device trips it means there is fault on the power line or motor Do not use this pump Disconnect the pump and have the problem corrected by a qualified...

Страница 10: ...n and status monitoring 3 Protection relay is an overload thermal protection device 4 Single phase MCB for secondary protection DOL Starter can be applied to motor connect in Delta or WYE Star connect...

Страница 11: ...all piping of construction debris and verify that the piping has passed a proper pressure test 2 Check the filter and other equipment for proper installation verifying all clamps and connections are p...

Страница 12: ...g groove on the pre filter body and replace the Lid To help keep the Lid from sticking tighten it by hand only 6 Put back the basket with opening face directly to the suction inlet as the picture show...

Страница 13: ...ires replacement Low pump capacity 1 Valve in the suction or discharge line partly closed 2 Suction or discharge line partly plugged 3 Suction or discharge line too small 4 Plugged basket in skimmer o...

Страница 14: ...ng for Lid Basket Pre Filter Body 2 0 Union Black White Colour Drain Plug with O ring Square Gasket M6 x 30 Screw for Pump Body Pump body for SB SR Screw for Impeller with O Ring O Ring for Diffuser D...

Страница 15: ...60Hz M8 20 Bolt for motor with washer Opening key Base with Nut Washer for SB10 Sb15 Base with Nut Washer for SB20 Sb30 Cable Box for SB SR Pump 220V 50Hz 220V 60Hz 380V 50Hz Cable Box for SB SR Pump...

Страница 16: ...Impeller SR20 110V 60Hz 220V 60Hz Impeller SR20 220V 50Hz 380V 50Hz Impeller SR10 220V 50Hz and 380V 50Hz SR15 110V 60Hz and 220V 60Hz Impeller SR15 220V 50Hz and 380V 50Hz SR30 110V 60Hz and 220V 60H...

Страница 17: ...ucts free from defects in materials and workmanship under normal use during warranty period The warranty period begins on the day of purchase and extends only to the original purchaser It is not trans...

Страница 18: ...STRIVE FOR CLEAR WATER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD...

Отзывы: