CAUTION before carrying out any serv ice on the pump: pump must be accessible at all times for  

        operation and service. Access must be free and without obstacles. 

- Disconnect pump from the mains or from switch contact switch. 

- Relieve all the pressure from the pump head and all liquid ends. 

- Drain or flush all dosing liquid from pump head. This operation can also be executed by disconnecting the 

pump from the plant by turning the pump upside-down for 15 to 30 seconds without connecting the tubing to 

the nipples; if this operation is not possible, dismount and remount the pump head using the four mounting 

screws. In the event of possible liquid ends leakage (wearing out or damage of "O" ring seals, valves  or 

hoses) the pump should immediately be brought to a stop, emptying and depressurising the discharge hose 

while taking all due safety precautions (gloves, goggles, overalls, etc.). 

- Whenever the pump is dismantled from installation, place back the RED protection caps on the nipples to 

avoid residual liquid being spilled.  

- When dismantling a pump, clean the pump and liquid ends removing all chemical additive residuals present 

on the housing and inside hydraulic components. 

- For disposing a unit, follow local authorities rules for disposing of equipments and chemical products; send 

parts to authorized recycling centers for correct disposal. 

DO NOT POLLUTE THE EARTH !!!! 

REMINDER

during maintenance operation bear in mind that discharge and suction valves are mounted in 

different position according to function

.     

5.0 – MAINTENANCE

1. 

Periodically check chemical additive tank level so as to avoid the pump operates without liquid. This would 

not damage the pump, but may damage the process plant due to lack of chemical. FX series dosing pumps 

are all supplied with level control setting. The level switch is not included therefore to be ordered separately. 

Level control stops pump operation once chemical level into the tank is lower than level switch, thus activating 

a L.E.D. on the pump  

2. 

Check the pump operating conditions at least every 6 months: 

- pump head position, screws, bolts and seals;  

- check more frequently where aggressive chemicals are pumped, especially: 

- If a reduction of the required additive concentration in the process plant is detected, this could be caused the 

reduction of the dosing pump flow rate by valves wearing, in which case they need to be replaced or by the 

clogging of the filter which has to be cleaned as in fig.13 here below. 

3. 

The Company suggests periodically cleaning hydraulic parts (valves and filter). We cannot say how often 

this cleaning should be done as it depends on the type of application, we also cannot suggest what cleaning 

agent to use as this will depend on the additive used.  

Operating suggestions when dosing sodium hypochlorite (most frequent case): 

a -

Disconnect the pins from the mains or from power switch;

b -

disconnect discharge hose from process plant;

c -

remove the suction hose (with filter) from the tank and dip it into clean water;

switch ON the dosing pump and let it

operate with water for 5 to 10 minutes;

d -

switch OFF the pump, dip the filter into a

hydrochloric acid solution and wait until end 

of cleaning;

e -

switch ON the pump again and operate it

with hydrochloric acid for 5 minutes in a 

closed-circuit, with  suction and discharge 

hose dipped into the same tank (fig.14);

f -

repeat the operation with water;

g -

re-connect hoses to dosing pump and

injection valve to the process plant; 

h -

re-tighten liquid end screws after 24 hours

in operation, and then after 3 months. 

Operator must always protect itself when handling hazardous feed chemicals. 

5.1 - HOW TO OPERATE WHEN DOSING SULPHURIC ACID 

In case of dosing Sulphuric Acid up to 96% or other aggressive chemicals, bear in mind the following: 

1. 

replace PVC suction hose with polyethylene discharge hose; 

2. 

empty any residual water from the pump head beforehand. 

Warning: 

if  water  mixes  with  sulphuric  acid  it  can  produce  a  large  quantity  of  gas  with  consequent 

overheating of the area causing damage to valves and pump head. This operation can also be done with the 

pump  disconnected  from  the  plant  by  turning  the  pump  upside-down  for  15  to  30  seconds  and  without 

connecting the hose to the nipples; if it’s not possible, unscrew the pump head, empty it and then remount it. 

EMAUX provides a special liquid ends configuration for Sulphuric Acid or other aggressive chemicals. 

Fig.14 

Foot valve / filter

  Injection valve

CLOSED WATER LOOP

Pump head cleaning 

  Fresh water bucket

Содержание CTRL2-5L

Страница 1: ...CTRL2 5L CTRL2 7L SERIES DUAL PARAMETER PH RX MICROCONTROLLER SOLENOID DRIVEN DOSING PUMP OPERATING INSTRUCTIONS AND MAINTENANCE EMPU12053149 ENGLISH...

Страница 2: ...ARAMETERS AND FUNCTIONS LAYOUT pH default page 12 10 0 PROGRAMMING CONTROLLER 11 0 CALIBRATION page 13 15 12 0 PROGRAMMING SET POINT 13 0 SET POINT SETTINGS page 15 17 14 0 ALLARM SETTINGS 15 0 RESET...

Страница 3: ...ger However save packaging it can be used for future shipments Before connecting the equipment ensure voltage ratings corresponds to local power supply You will find these characteristics in the produ...

Страница 4: ...IALS PARTS IN CONTACT WITH LIQUID STANDARD VERSION UPON REQUEST Pump head PP PVDF PMMA MEMO1 NOTE AISI316 Diaphragm PTFE Ball check valve CERAMIC AISI 316 Pump head Nipples Hose nut PP PVDF AISI 316 S...

Страница 5: ...nt side for sliding pump rear slots Mounting bracket side view Fig 3 Drill two holes and insert dibbles then screw in bracket Slide pump into slots Performance curves fig 2 are obtained testing the pu...

Страница 6: ...7 always use curved joints with suction or discharge hose Try to keep both the suction and discharge hose as straight as possible avoiding all unnecessary bends always use our standard strainer foot v...

Страница 7: ...e condition should be checked at regular intervals because excessive wear could cause additive to drip into the plant even when the pump is OFF If the problem persists install a proper calibrated coun...

Страница 8: ...ls are pumped especially If a reduction of the required additive concentration in the process plant is detected this could be caused the reduction of the dosing pump flow rate by valves wearing in whi...

Страница 9: ...ns CONNECTOR 1 CONNECTOR 1 Level switch connection fig 15 Configurations Pin 1 NO connection Pin 2 NO connection Pin 3 Level switch wire Pin 4 Level switch wire PUMP LOWER SIDE Power cable clamp pH or...

Страница 10: ...al mode selection of proportional range value Delay adjustment Delay at powering ON electrodespolarization Stand by for cleaning electrodesand sensors or re calibration 7 3 LEVEL CONTROL ONLY CTRL2 L...

Страница 11: ...quency based to maximum measuring value 9 0 PARAMETERS AND FUNCTIONS pH default DEFAULT Set point setting 7 2 Hysteresi s setting 0 1 Choice of intervention of dosing field acid alkaline Acid Selectio...

Страница 12: ...ogramming moves to measuring mode display will show current measured value Press OK to enter menus it will show SETPOINT menu using or buttons to scroll all 4 menus Set point menu Calibration menu Ala...

Страница 13: ...ature compensation that is setting the temperature at the same value of the system to be treated and such value will remain constant Also it s possible to switch from C celsius defau lt to F Fahrenhei...

Страница 14: ...POINT 2 Dip RX electrode into buffer solution 475 or 250 or 650mV Using or adjust until display shows the buffer solution value Press OK to confirm BNC CONNECTOR 12 0 PROGRAMMING SET POINT NOTE To ha...

Страница 15: ...ed by the user at max frequency chapter 11 5 and will stop once reached required set point PROP with this mode the pump will dose proportionally to the current measured value and its distance to selec...

Страница 16: ...00 120 imp min STEP 3 With and select minimum measured value to correspond dosing pump minimum injection frequency Press OK to confirm and exit Set point menu Press ESC to return to measuring mode 15...

Страница 17: ...are steps for RESET procedure Switch OFF and ON the unit Press at the same time ESC and OK until display will show the latest firmware revision e g 02 3 3 then will appear SET UP and default paramete...

Страница 18: ...ion d Check system pressure cause 2 chemical can produce crystalline deposits in the hydraulic parts or clogging the filter 2 GREEN LED LIT AND RED LED FLASHING PUMP PULSES BUT PUMP IS NOT PRIMING NO...

Страница 19: ...t manufacturer Customer Service Dealer or Distributor 8 LIQUID IS LEAKING from back of the pump head cause 1 diaphragm pump head o ring is not sealing because worned out or faulty due to not compatibl...

Страница 20: ...If the reading remains erroneous proceed to treatment 2 2 Immerse the tip of the electrode in a 20 solution of ammonium bifluoride NH2F HF for two or three minutes then rinse with water and make anoth...

Страница 21: ...njection fitting Injection non return valve N Delivery line to process plant O By pass from system line to electrode cell holder P ECELL1 off line electrode holder code SPS0000901 Q PH or RX electrode...

Страница 22: ...EMAUX customer service 1 pump head complete 2 diaphragm pump head o ring 3 PTFE diaphragm 4 piston flange 5 9 power cable assembly 6 front controls panel 7 housing 8 controls PCB printed circuit boar...

Страница 23: ...ir bleed 5 VALVE SPACER air bleed 6 P HEAD BALL CHECK VALVE ASSEMBLY 7 NIPPLE O RING 8 NIPPLE PP 3 8 9 PROTECTION CAP 10 HOSE NUT PP 11 12 13 14 15 AIR BLEED KNOB ASSEMBLY 16 17 PUMP HEAD SCREWS 12 18...

Страница 24: ...HOSE NUT PVDF 8 DIAPHRAGM PUMP HEAD O RING 9 PUMP HEAD SCREWS BUSH 10 DISCHARGE BALL CHECK ASSEMBLY 11 AIR BLEED BALL CHECK ASSEMBLY 12 AIR BLEED KNOB ASSEMBLY 13 O RING BLEED OUTLET 14 PUMP HEAD SCR...

Страница 25: ...RING 9 PUMP HEAD SCREWS BUSH 10 11 AIR BLEED BALL CHECK ASSEMBLY 12 DISCHARGE BALL CHECK ASSEMBLY 13 PUMP HEAD SCREWS Assembly includes Housing and Nipple 3 8 in PVDF PVDF PUMP HEAD LIP VALVE 2 VALVE...

Страница 26: ...ON CAP 10 HOSE NUT 11 DIAPHRAGM PUMP HEAD O RING 12 PUMP HEAD SCREWS 13 PUMP HEAD SCREWS BUSH ONLY CTRL2 7L SERIES OVERALL DIMENSIONS mm PMMA pump head polymer viscous liquid configuration includes Ce...

Страница 27: ...alves in FPM standard EPDM SILICON NBR INJECTION VALVE FITTING NO RETURN VALVE STANDARD INJECTION VALVE A CYLINDER SLEEVE NO RETURN VALVE B NIPPLE O RING 2062 C INJECTION FITING PP D HOSE NUT PP Valid...

Страница 28: ...cables of the previous mentioned components A SUCTION LANCE B LEVEL SWITCH C FOOT VALVE FILTER D AIR BLEED HOSE E PUMP SUCTION HOSE F LEVEL SWITCH CABLE Suction lance is made in PVC and are available...

Страница 29: ...in PP PVC or PVDF RELIEF VALVE or BACK PRESSURE VALVE This valve can be utilized either as RELIEF VALVE opens an overflow line if the preset pressure limit is exceeded This application also is a safet...

Страница 30: ...30 MEASUREMENTS AND PROGRAMMING NOTES...

Страница 31: ...RL2 Version Emaux Zhong Shan Swimming Pool Equipment Co Ltd Long Zhu Industrial Park Nan Lang Industrial Area Nam Lang Town ZhongShan City Guangdong Province China Tel 0760 8552 7988 Fax 0760 8552 718...

Отзывы: