emaux CTRL2-5L Скачать руководство пользователя страница 5

5

2.4 - TECHNICAL CHARACTERISTICS 

CTRL2 - 7L

Pump   

Max Flow / Max Pressure

Start up

* performance

Frequency Stroke volume Pump head

Valves 

type range

l/h

bar

l/h

bar

imp/min

cc(ml) / stroke

type

types

CTRL2 - 7L

 

CTRL2 - 5L

7

4

120

0,98

PP 3/8"

Ball checks

CTRL2 - 5L

5

5

120

0,69

PP 3/8"

“Lip” types

Hose size: 

4 x 6 mm 

(available 6x8 fittings)

Max suction lift: 

2 m

Power consumption: 

Current consumption: 

-

*NOTE:  

“Start up” 

performances are available when the pump starts the operations and are constant only if duties are 

               not continuous (working for time periods not over 20/30 min and with at least 15 min rest).

2.5 – PERFORMANCE CURVES 

3.0 – COMMISSIONING

CTRL2-7L series is provided with a 

quick mounting support bracket:

 

a. 

- Install the pump in a dry place, firmly  to avoid vibrations, and well away from sources of heat and, in any  

case, at environmental temperatures not exceeding 40°C. The minimum operating temperature depends on 

the liquid to be pumped, bearing in mind that it must always remain in a liquid state. 

b. -

 Fix the wall support brackets as shown in (fig.3).

Rear side to place 

against wall or panel 

Front side for sliding 

pump rear slots 

Mounting 

bracket 

side view 

          

Fig.3

Drill two holes and 

insert dibbles then 

screw in bracket

Slide 

pump 

into slots

Performance curves (fig.2) are obtained testing the pump with water at room temperature and nominal suction height. 

The above diagrams indicate max metering pump flow variation in relation to the working pressure in the plant; the 

diagrams also include i.v.p. flow loss (injection valve pressure about 0,3÷0,4 bar). 

REMINDER: ratings vary with a tolerance of ±5% CTRL2 - 7L / ±10% CTRL2 - 5L which must be taken into account when choosing 

the pump typ: above diagrams show the performance and some of the curves have slight variation from nominal rating. 

NOTE

when programming pump operations  keep in  mind  that  flow  variation are  related  to  the  system  pressure 

variation; refer always to pump curves. Also consider that unexpected flow variations may occur for reasons not related 

to pump functioning (viscosity, specific weight, sedimentation, etc). 

bar

l/h

i.v.p.

0

10

15

5

7

4

5

10

15

2,5-15

1,5-10

5,5-07

07-04

         

dotted line = 

Start-up curves

         

straight line = 

Standard curves

CTRL2 7L performance curves 

CTRL2 - 5L performance curves 

bar

l/h

i.v.p.

0

10

5

5

10

6

4

2

07-02

05-04

2,5-06

01-05

Fig.2

CTRL2 - 7L 37 watt CTRL2 - 5L 

32 watt

 

CTRL2 - 7L 0,16 Amp CTRL2 - 5L 

0,14 Amp

 

Содержание CTRL2-5L

Страница 1: ...CTRL2 5L CTRL2 7L SERIES DUAL PARAMETER PH RX MICROCONTROLLER SOLENOID DRIVEN DOSING PUMP OPERATING INSTRUCTIONS AND MAINTENANCE EMPU12053149 ENGLISH...

Страница 2: ...ARAMETERS AND FUNCTIONS LAYOUT pH default page 12 10 0 PROGRAMMING CONTROLLER 11 0 CALIBRATION page 13 15 12 0 PROGRAMMING SET POINT 13 0 SET POINT SETTINGS page 15 17 14 0 ALLARM SETTINGS 15 0 RESET...

Страница 3: ...ger However save packaging it can be used for future shipments Before connecting the equipment ensure voltage ratings corresponds to local power supply You will find these characteristics in the produ...

Страница 4: ...IALS PARTS IN CONTACT WITH LIQUID STANDARD VERSION UPON REQUEST Pump head PP PVDF PMMA MEMO1 NOTE AISI316 Diaphragm PTFE Ball check valve CERAMIC AISI 316 Pump head Nipples Hose nut PP PVDF AISI 316 S...

Страница 5: ...nt side for sliding pump rear slots Mounting bracket side view Fig 3 Drill two holes and insert dibbles then screw in bracket Slide pump into slots Performance curves fig 2 are obtained testing the pu...

Страница 6: ...7 always use curved joints with suction or discharge hose Try to keep both the suction and discharge hose as straight as possible avoiding all unnecessary bends always use our standard strainer foot v...

Страница 7: ...e condition should be checked at regular intervals because excessive wear could cause additive to drip into the plant even when the pump is OFF If the problem persists install a proper calibrated coun...

Страница 8: ...ls are pumped especially If a reduction of the required additive concentration in the process plant is detected this could be caused the reduction of the dosing pump flow rate by valves wearing in whi...

Страница 9: ...ns CONNECTOR 1 CONNECTOR 1 Level switch connection fig 15 Configurations Pin 1 NO connection Pin 2 NO connection Pin 3 Level switch wire Pin 4 Level switch wire PUMP LOWER SIDE Power cable clamp pH or...

Страница 10: ...al mode selection of proportional range value Delay adjustment Delay at powering ON electrodespolarization Stand by for cleaning electrodesand sensors or re calibration 7 3 LEVEL CONTROL ONLY CTRL2 L...

Страница 11: ...quency based to maximum measuring value 9 0 PARAMETERS AND FUNCTIONS pH default DEFAULT Set point setting 7 2 Hysteresi s setting 0 1 Choice of intervention of dosing field acid alkaline Acid Selectio...

Страница 12: ...ogramming moves to measuring mode display will show current measured value Press OK to enter menus it will show SETPOINT menu using or buttons to scroll all 4 menus Set point menu Calibration menu Ala...

Страница 13: ...ature compensation that is setting the temperature at the same value of the system to be treated and such value will remain constant Also it s possible to switch from C celsius defau lt to F Fahrenhei...

Страница 14: ...POINT 2 Dip RX electrode into buffer solution 475 or 250 or 650mV Using or adjust until display shows the buffer solution value Press OK to confirm BNC CONNECTOR 12 0 PROGRAMMING SET POINT NOTE To ha...

Страница 15: ...ed by the user at max frequency chapter 11 5 and will stop once reached required set point PROP with this mode the pump will dose proportionally to the current measured value and its distance to selec...

Страница 16: ...00 120 imp min STEP 3 With and select minimum measured value to correspond dosing pump minimum injection frequency Press OK to confirm and exit Set point menu Press ESC to return to measuring mode 15...

Страница 17: ...are steps for RESET procedure Switch OFF and ON the unit Press at the same time ESC and OK until display will show the latest firmware revision e g 02 3 3 then will appear SET UP and default paramete...

Страница 18: ...ion d Check system pressure cause 2 chemical can produce crystalline deposits in the hydraulic parts or clogging the filter 2 GREEN LED LIT AND RED LED FLASHING PUMP PULSES BUT PUMP IS NOT PRIMING NO...

Страница 19: ...t manufacturer Customer Service Dealer or Distributor 8 LIQUID IS LEAKING from back of the pump head cause 1 diaphragm pump head o ring is not sealing because worned out or faulty due to not compatibl...

Страница 20: ...If the reading remains erroneous proceed to treatment 2 2 Immerse the tip of the electrode in a 20 solution of ammonium bifluoride NH2F HF for two or three minutes then rinse with water and make anoth...

Страница 21: ...njection fitting Injection non return valve N Delivery line to process plant O By pass from system line to electrode cell holder P ECELL1 off line electrode holder code SPS0000901 Q PH or RX electrode...

Страница 22: ...EMAUX customer service 1 pump head complete 2 diaphragm pump head o ring 3 PTFE diaphragm 4 piston flange 5 9 power cable assembly 6 front controls panel 7 housing 8 controls PCB printed circuit boar...

Страница 23: ...ir bleed 5 VALVE SPACER air bleed 6 P HEAD BALL CHECK VALVE ASSEMBLY 7 NIPPLE O RING 8 NIPPLE PP 3 8 9 PROTECTION CAP 10 HOSE NUT PP 11 12 13 14 15 AIR BLEED KNOB ASSEMBLY 16 17 PUMP HEAD SCREWS 12 18...

Страница 24: ...HOSE NUT PVDF 8 DIAPHRAGM PUMP HEAD O RING 9 PUMP HEAD SCREWS BUSH 10 DISCHARGE BALL CHECK ASSEMBLY 11 AIR BLEED BALL CHECK ASSEMBLY 12 AIR BLEED KNOB ASSEMBLY 13 O RING BLEED OUTLET 14 PUMP HEAD SCR...

Страница 25: ...RING 9 PUMP HEAD SCREWS BUSH 10 11 AIR BLEED BALL CHECK ASSEMBLY 12 DISCHARGE BALL CHECK ASSEMBLY 13 PUMP HEAD SCREWS Assembly includes Housing and Nipple 3 8 in PVDF PVDF PUMP HEAD LIP VALVE 2 VALVE...

Страница 26: ...ON CAP 10 HOSE NUT 11 DIAPHRAGM PUMP HEAD O RING 12 PUMP HEAD SCREWS 13 PUMP HEAD SCREWS BUSH ONLY CTRL2 7L SERIES OVERALL DIMENSIONS mm PMMA pump head polymer viscous liquid configuration includes Ce...

Страница 27: ...alves in FPM standard EPDM SILICON NBR INJECTION VALVE FITTING NO RETURN VALVE STANDARD INJECTION VALVE A CYLINDER SLEEVE NO RETURN VALVE B NIPPLE O RING 2062 C INJECTION FITING PP D HOSE NUT PP Valid...

Страница 28: ...cables of the previous mentioned components A SUCTION LANCE B LEVEL SWITCH C FOOT VALVE FILTER D AIR BLEED HOSE E PUMP SUCTION HOSE F LEVEL SWITCH CABLE Suction lance is made in PVC and are available...

Страница 29: ...in PP PVC or PVDF RELIEF VALVE or BACK PRESSURE VALVE This valve can be utilized either as RELIEF VALVE opens an overflow line if the preset pressure limit is exceeded This application also is a safet...

Страница 30: ...30 MEASUREMENTS AND PROGRAMMING NOTES...

Страница 31: ...RL2 Version Emaux Zhong Shan Swimming Pool Equipment Co Ltd Long Zhu Industrial Park Nan Lang Industrial Area Nam Lang Town ZhongShan City Guangdong Province China Tel 0760 8552 7988 Fax 0760 8552 718...

Отзывы: