emaux 9023901 Скачать руководство пользователя страница 7

IMPORTANT SAFETY

 

INSTRUCTIONS     P6

1450RPM 50Hz

1200

900

600

300

U.S.g.p.m

H(m)

22
20
18
16
14
12
10

8
6
4
2
0

0

30

60

90

120

150

180

210

240

270

300

4500

3750

3000

2250

1500

750

0

55 60 65

70 75

80

85

85

80

H

(

ft

)

10

20

30

40

50

60

70

Q(m

³/

h)

Q(LPM)

The user guide you are holding includes essential information on the safety measures to be 

implemented  for  installation  and  start-up.  Therefore,  the  installer  as  well  as  the  user  must 

read the instructions before beginning installation and start-up. Keep this manual for future 

reference.

The pump should be installed according to your local electrical installation ordinances and 

regulations. Only qualified, licensed personnel should install the pump and the wiring.

This  appliance  cannot  be  used  by  persons  (including  children)  with  reduced  physical,  sensor y  or  mental 

capabilities  or  lack  of  experience  and  knowledge  unless  they  have  been  given  super vision  or  instruction 

concerning use of the appliance in a safe way and understand the hazards involved. Children must not play with 

the appliance.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensor y 

or  mental  capabilities  or  lack  of  experience  and  knowledge  if  they  have  been  given  super vision  or  instruction 

concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with 

the appliance. Cleaning and user maintenance shall not be made by children without super vision.

3. IMPORTANT SAFETY

 

INSTRUCTIONS

4. TRANSPORT AND STORAGE

The pump is fastened securely a wooden box for  shipment. It should be stored in a dr y area. 

The  center  of  the  pump  locate  at  the  middle  of  the  pump.  It  is  recommended  to  place  the  lifting  strap  under 

between Motor to  Body and Body to pre - filter  body to  lift the pump  in the following way:  

The Eye bolt is only to use for motor lifting.

Содержание 9023901

Страница 1: ...HYDRAU POWER PLASTIC PUMP APS SERIES OWNER S MANUAL Installation and Operation USER MANUAL Model APS Series EMPU22121601...

Страница 2: ...ER 6 3 VARIABLE FREQUENCY DRIVE VFD 6 4 SOFT STARTER 7 START UP 8 PRE FILTER BASKET MAINTIANCE 9 WINTERIZING 10 TROUBLE SHOOTING 11 TYPICAL INSTALLATION EXAMPLE 12 REPLACEMENT PARTS 13 TERMS OF THE WA...

Страница 3: ...e only 7 Switch OFF pump power before servicing and disconnecting the main circuit to the pump 8 Never change the filter control valve position while the pump is running RISK OF ELECTRICAL SHOCK COMPR...

Страница 4: ...bs or 1 2 A properly designed and tested suction limiting vent system or 1 3 An automatic pump shut off system 1 A SVRS meeting ASME ANSI A112 19 17 and or ASTM F2387 or 2 A properly designed and test...

Страница 5: ...lay with the appliance Cleaning and user maintenance shall not be made by children without supervision 3 The appliance shall be installed in accordance with national wiring regulations means for disco...

Страница 6: ...h Power KW 8 10 12 Noise dB 14 16 APS750P APS1000P APS1500P 4 5 5 7 5 11 72 72 68 68 95 130 90 120 210 270 82 110 185 260 75 105 180 250 65 90 160 240 50 80 135 210 APS550P PERFORMANCE CURVE 940 5 5HP...

Страница 7: ...ack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children must not play with the...

Страница 8: ...mps The pump should be located nearby as close as possible the pool or spa to reduce friction loss and improve efficiency It is recommended at least 1 5 meter from pool water and 3 meters according to...

Страница 9: ...the problem corrected by a qualified service representative before using Press the reset button to reset the RDC GFCI devices after fixed It will keeps the circuit shut off and will not reset if the p...

Страница 10: ...ine Starter that include 1 Motor Circuit Breaker is a short circuit magnetic protection devices 2 Control unit for Run and Stop operation and status monitoring 3 Protection relay is an overload therma...

Страница 11: ...he pump body to show the right direction Turn on the pump in one second and check the motor rotation direction is correct or not The motor will rotate in Clock wise direction if any two cables are int...

Страница 12: ...ble frequency driver for better starting and energy saving purpose The connection is simple it is just connect the 3 phase output of the variable frequency drive to the pump in Delta or Star configura...

Страница 13: ...que transients associated with electro mechanical reduced voltage starters 2 Voltage or current is applied gradually without the voltage and current transients associated with electro mechanical reduc...

Страница 14: ...ear all piping of construction debris and verify that the piping has passed a proper pressure test 2 Check the filter and other equipment for proper installation verifying all clamps and connections a...

Страница 15: ...the lid O ring if damaged replace Turn off the pump at the breaker Close the inlet and discharge valves Discharge the water by drain on the pre filter bottom Release the two Lid fastener of the neck c...

Страница 16: ...of 3 Phase Circuit 5 Pump Shaft rotating in wrong direction 10 TROUBLE SHOOTING Problem Corrective Action Pump Will Not Prime 1 No water in Pre filter Lid is not tight Damaged lid O Ring 2 Water level...

Страница 17: ...tion of the pump so as to prevent the draining off of the water outlet pipe after the pump is stopped The soft connection can prevent the forming of cavitation Pressure gauge can check the working pre...

Страница 18: ...0HP 15HP Pre Filter Body APS5 5HP 7 5HP Pre Filter Body APS10HP 15HP Drain Plug Ding Qing O ring O ring APS5 5HP 7 5HP O ring APS10HP 15HP 1 1 1 1 2 2 1 1 9 420336559 420336556 Pump Body APS5 5HP 7 5H...

Страница 19: ...eriod begins on the day of purchase and extends only to the original purchaser It is not transferable to anyone who subsequently purchases the product from you It excludes all expendable parts During...

Страница 20: ...YOUR PREMIER SUPPLIER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD...