emaux 9023901 Скачать руководство пользователя страница 5

1. Hydrau-Power APS series pump deliver y Emaux latest technology in pump design. 

2.  It  is  constructed  in  reinforced  plastic  pump  body  in  lightweight  and  corrosion-resistant  that  suitable  for 

marine applications. 

3. Motor design in IE3 class premium efficiency standard provide incredibly efficient and low noise level. 

4.  High  water  flow  impeller  design  by  computational  fluid  dynamics  (CFD)  analysis  optimize  the  pump 

performance than comparable pumps. 

5.  Large  volume  Detachable  pre-filter  with  basket 

design  provide  high  flow  rate  application  and 

flexible installation. 

6.  ANSI  Class  150  and  DIN  PN10  compatible  flange 

standard  design  to  fit  into  different  piping  system 

environments. 

7. It is three phase electrical high power driving motor 

that  is  good  for  swimming  pool  and  Sea  Water 

applications. 

APS SERIES PLASTIC PUMP OVERVIEW    P4

1. A protective device is to be installed in the fixed wiring.

2.  This  appliance  can  be  used  by  children  aged  from  8  years  and  above  and  persons  with 

reduced  physical,  sensor y  or  mental  capabilities  or  lack  of  experience  and  knowledge  if 

they have been given super vision or instruction concerning use of the appliance in a safe 

way  and  understand  the  hazards  involved.  Children  shall  not  play  with  the  appliance.  Cleaning  and  user 

maintenance shall not be made by children without super vision.

3. The appliance shall be installed in accordance with national wiring regulations means for disconnection must 

be  incorporated  in  the  fixed  wiring  in  accordance  with  the  wiring  rules.  A  disconnected  incorporated  in  the 

fixed wiring is to be provided.

4. The pump is to be supplied through a residual current device (RCD) or Ground Fault Circuit Interrupt (GFCI) 

having a rated residual operation current not exceeding 30mA. 

5. The pump is to be supplied by an isolating transformer or supplied through a residual current device (RCD) 

having a rated residual operating current not exceeding 30mA.

CAUTION!

Correct disposal of this product

This  symbol  on  the  product,  or  in  its  packaging,  indicates  that  this 

product  may  not  be  treated  as  household  waste.  Instead,  it  should  be 

taken  to  the  appropriate  waste  collection  point  for  the  recycling  of 

electrical and electronic equipment. By ensuring this product is disposed 

of  correctly,  you  will  help  prevent  potential  negative  consequences  for 

the environment and human health, which could other wise be caused by 

the  inappropriate  waste  handling  of  this  product.  For  more  detailed 

information about the recycling of this product, please contact your local 

council,  your  household  waste  disposal  ser vice,  or  the  shop  where  you 

purchased the product.

1. APS SERIES PLASTIC PUMP OVERVIEW

Содержание 9023901

Страница 1: ...HYDRAU POWER PLASTIC PUMP APS SERIES OWNER S MANUAL Installation and Operation USER MANUAL Model APS Series EMPU22121601...

Страница 2: ...ER 6 3 VARIABLE FREQUENCY DRIVE VFD 6 4 SOFT STARTER 7 START UP 8 PRE FILTER BASKET MAINTIANCE 9 WINTERIZING 10 TROUBLE SHOOTING 11 TYPICAL INSTALLATION EXAMPLE 12 REPLACEMENT PARTS 13 TERMS OF THE WA...

Страница 3: ...e only 7 Switch OFF pump power before servicing and disconnecting the main circuit to the pump 8 Never change the filter control valve position while the pump is running RISK OF ELECTRICAL SHOCK COMPR...

Страница 4: ...bs or 1 2 A properly designed and tested suction limiting vent system or 1 3 An automatic pump shut off system 1 A SVRS meeting ASME ANSI A112 19 17 and or ASTM F2387 or 2 A properly designed and test...

Страница 5: ...lay with the appliance Cleaning and user maintenance shall not be made by children without supervision 3 The appliance shall be installed in accordance with national wiring regulations means for disco...

Страница 6: ...h Power KW 8 10 12 Noise dB 14 16 APS750P APS1000P APS1500P 4 5 5 7 5 11 72 72 68 68 95 130 90 120 210 270 82 110 185 260 75 105 180 250 65 90 160 240 50 80 135 210 APS550P PERFORMANCE CURVE 940 5 5HP...

Страница 7: ...ack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children must not play with the...

Страница 8: ...mps The pump should be located nearby as close as possible the pool or spa to reduce friction loss and improve efficiency It is recommended at least 1 5 meter from pool water and 3 meters according to...

Страница 9: ...the problem corrected by a qualified service representative before using Press the reset button to reset the RDC GFCI devices after fixed It will keeps the circuit shut off and will not reset if the p...

Страница 10: ...ine Starter that include 1 Motor Circuit Breaker is a short circuit magnetic protection devices 2 Control unit for Run and Stop operation and status monitoring 3 Protection relay is an overload therma...

Страница 11: ...he pump body to show the right direction Turn on the pump in one second and check the motor rotation direction is correct or not The motor will rotate in Clock wise direction if any two cables are int...

Страница 12: ...ble frequency driver for better starting and energy saving purpose The connection is simple it is just connect the 3 phase output of the variable frequency drive to the pump in Delta or Star configura...

Страница 13: ...que transients associated with electro mechanical reduced voltage starters 2 Voltage or current is applied gradually without the voltage and current transients associated with electro mechanical reduc...

Страница 14: ...ear all piping of construction debris and verify that the piping has passed a proper pressure test 2 Check the filter and other equipment for proper installation verifying all clamps and connections a...

Страница 15: ...the lid O ring if damaged replace Turn off the pump at the breaker Close the inlet and discharge valves Discharge the water by drain on the pre filter bottom Release the two Lid fastener of the neck c...

Страница 16: ...of 3 Phase Circuit 5 Pump Shaft rotating in wrong direction 10 TROUBLE SHOOTING Problem Corrective Action Pump Will Not Prime 1 No water in Pre filter Lid is not tight Damaged lid O Ring 2 Water level...

Страница 17: ...tion of the pump so as to prevent the draining off of the water outlet pipe after the pump is stopped The soft connection can prevent the forming of cavitation Pressure gauge can check the working pre...

Страница 18: ...0HP 15HP Pre Filter Body APS5 5HP 7 5HP Pre Filter Body APS10HP 15HP Drain Plug Ding Qing O ring O ring APS5 5HP 7 5HP O ring APS10HP 15HP 1 1 1 1 2 2 1 1 9 420336559 420336556 Pump Body APS5 5HP 7 5H...

Страница 19: ...eriod begins on the day of purchase and extends only to the original purchaser It is not transferable to anyone who subsequently purchases the product from you It excludes all expendable parts During...

Страница 20: ...YOUR PREMIER SUPPLIER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD...