emaux 9023901 Скачать руководство пользователя страница 19

Front part of Base(APS10HP-15HP)

1

TERMS OF THE WARRANTY    P18

Key NO

Part NO

Product Description

QTY

15

111010042

111010039

O-ring for flange(APS5.5HP-7.5HP)

O-ring for flange(APS10HP-15HP)

1

1

113006715

Mechanical Seal(APS5.5HP-7.5HP)

1

113006710

Mechanical Seal(APS10HP-15HP)

1

16

420576572

Volute hind side(APS5.5HP-7.5HP)

1

420576570

Volute hind side(APS10HP-15HP)

1

17

420206559

Flange(APS5.5HP-7.5HP)

1

420206556

Flange(APS5.5HP-7.5HP)

1

18

104036713

Motor(APS5.5HP)

1

104036714

Motor(APS7.5HP)

1

104036711

Motor(APS10HP)

1

104036712

Motor(APS15HP)

1

19

20

21

22

111000028

111000027

420126568

420126564

111000026

420126567

Arch Cushion (APS5.5HP-7.5HP)

Arch Cushion APS(15HP)

Arch Cushion APS(10HP)

Rear of Base(APS5.5HP-7.5HP)

Rear of Base(APS10HP-15HP)

Front part of Base(APS5.5HP-7.5HP)

1

1

1

1

1

1

420126563

Front part of Base(APS10HP-15HP)

1

13. TERMS OF THE WARRANTY

As  original  purchaser  of  this  equipment  have  purchased  from  Emaux  Water  Technology  Co  Ltd,  through  Authorized 

International  Distributor  or  Dealer,  warrants  its  products  free  from  defects  in  materials  and  workmanship  under 

normal  use  during  warranty  period.  The  warranty  period  begins  on  the  day  of  purchase  and  extends  only  to  the 

original purchaser. It is not transferable to anyone who subsequently purchases the product from you. It excludes all 

expendable parts.

During the warranty period, Emaux authorized reseller will repair or replace defective parts with new parts or, at the 

option of Emaux, ser viceable used parts that are equivalent or superior to new parts in performance.

This Limited Warranty extends only to products purchased from Emaux authorized reseller. This Limited Warranty does 

not extend to any product that has been damaged or rendered defective

(a) as a result of accident, misuse or abuse; 

(b) as a result of an act of God; 

(c) by operation outside the usage parameters stated herein; 

(d) by the use of parts not manufactured or sold by Emaux; 

(e) by modification of the product; 

(f) as a result of war or terrorist attack ; or 

(g) as a result of ser vice by anyone other than Emaux authorized reseller or authorized agent.

EXCEPT  AS  EXPRESSLY  SET  FORTH  IN  THIS  WARRANTY,  EMAUX  MAKES  NO  OTHER  WARRANTIES  EXPRESSED  OR 

IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 

EMAUX  EXPRESSLY  DISCLAIMS  ALL  WARRANTIES  NOT  STATED  IN  THIS  LIMITED  WARRANTY.  ANY  IMPLIED 

WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS EXPRESS LIMITED WARRANTY.

Содержание 9023901

Страница 1: ...HYDRAU POWER PLASTIC PUMP APS SERIES OWNER S MANUAL Installation and Operation USER MANUAL Model APS Series EMPU22121601...

Страница 2: ...ER 6 3 VARIABLE FREQUENCY DRIVE VFD 6 4 SOFT STARTER 7 START UP 8 PRE FILTER BASKET MAINTIANCE 9 WINTERIZING 10 TROUBLE SHOOTING 11 TYPICAL INSTALLATION EXAMPLE 12 REPLACEMENT PARTS 13 TERMS OF THE WA...

Страница 3: ...e only 7 Switch OFF pump power before servicing and disconnecting the main circuit to the pump 8 Never change the filter control valve position while the pump is running RISK OF ELECTRICAL SHOCK COMPR...

Страница 4: ...bs or 1 2 A properly designed and tested suction limiting vent system or 1 3 An automatic pump shut off system 1 A SVRS meeting ASME ANSI A112 19 17 and or ASTM F2387 or 2 A properly designed and test...

Страница 5: ...lay with the appliance Cleaning and user maintenance shall not be made by children without supervision 3 The appliance shall be installed in accordance with national wiring regulations means for disco...

Страница 6: ...h Power KW 8 10 12 Noise dB 14 16 APS750P APS1000P APS1500P 4 5 5 7 5 11 72 72 68 68 95 130 90 120 210 270 82 110 185 260 75 105 180 250 65 90 160 240 50 80 135 210 APS550P PERFORMANCE CURVE 940 5 5HP...

Страница 7: ...ack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children must not play with the...

Страница 8: ...mps The pump should be located nearby as close as possible the pool or spa to reduce friction loss and improve efficiency It is recommended at least 1 5 meter from pool water and 3 meters according to...

Страница 9: ...the problem corrected by a qualified service representative before using Press the reset button to reset the RDC GFCI devices after fixed It will keeps the circuit shut off and will not reset if the p...

Страница 10: ...ine Starter that include 1 Motor Circuit Breaker is a short circuit magnetic protection devices 2 Control unit for Run and Stop operation and status monitoring 3 Protection relay is an overload therma...

Страница 11: ...he pump body to show the right direction Turn on the pump in one second and check the motor rotation direction is correct or not The motor will rotate in Clock wise direction if any two cables are int...

Страница 12: ...ble frequency driver for better starting and energy saving purpose The connection is simple it is just connect the 3 phase output of the variable frequency drive to the pump in Delta or Star configura...

Страница 13: ...que transients associated with electro mechanical reduced voltage starters 2 Voltage or current is applied gradually without the voltage and current transients associated with electro mechanical reduc...

Страница 14: ...ear all piping of construction debris and verify that the piping has passed a proper pressure test 2 Check the filter and other equipment for proper installation verifying all clamps and connections a...

Страница 15: ...the lid O ring if damaged replace Turn off the pump at the breaker Close the inlet and discharge valves Discharge the water by drain on the pre filter bottom Release the two Lid fastener of the neck c...

Страница 16: ...of 3 Phase Circuit 5 Pump Shaft rotating in wrong direction 10 TROUBLE SHOOTING Problem Corrective Action Pump Will Not Prime 1 No water in Pre filter Lid is not tight Damaged lid O Ring 2 Water level...

Страница 17: ...tion of the pump so as to prevent the draining off of the water outlet pipe after the pump is stopped The soft connection can prevent the forming of cavitation Pressure gauge can check the working pre...

Страница 18: ...0HP 15HP Pre Filter Body APS5 5HP 7 5HP Pre Filter Body APS10HP 15HP Drain Plug Ding Qing O ring O ring APS5 5HP 7 5HP O ring APS10HP 15HP 1 1 1 1 2 2 1 1 9 420336559 420336556 Pump Body APS5 5HP 7 5H...

Страница 19: ...eriod begins on the day of purchase and extends only to the original purchaser It is not transferable to anyone who subsequently purchases the product from you It excludes all expendable parts During...

Страница 20: ...YOUR PREMIER SUPPLIER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD...