Installation
33
5.9 Activating manual operating mode
The manual mode enables the precise alignment of the gripper arm.
The following figure shows the operating side of the Autoloader with the side cover removed:
Fig. 17: Operating side of the Autoloader CS-i/CS-d with the side cover removed
Position
Component
Description
1
Electrical connection of the safety
circuit
Internal electrical connection for manual mode
2
Button for manual control
For going through the motion sequence of the
Autoloader in individual steps
Activate manual mode as follows:
1. Ensure that the assembly steps 5.1 to 5.6 have been carried out.
2. Connect the power plug on the supplied
power supply unit to the operating company’s
power supply.
3. Keep the button for manual control (
2
) pressed and plug the power cord from the power
supply unit into the electrical connection of the safety circuit (
1
).
4. Let the button (
2
) go as soon as you hear an acoustic signal from the Autoloader.
Manual mode has been activated.
2
1