All bare metal wires, screens or others not covered by the terminal shall be
thoroughly covered in a shrink tube to avoid unintended contact between
wires, housing or similar.
Only one conductor is allowed in each terminal of a terminal block/row for
external connections. This is not related to terminals that are integrated
parts of internal components of the equipment (such as relays and
contactors).
Also see Appendix B Earthing Methods in Maritime Installations on page 85.
Note!
Not following the recommended earthing guidelines may result in unwanted
system behavior.
•
Strip the wire-end to 8
–
9 mm (0.31in
–
0.35in).
•
Insert the wires according to the labeling.
All terminals can accommodate wires of cross-section
0.5
–
2.5 mm
2
/0.02
–
0.10 in
2
. The cable must be compliant to the ISO 11898-2
standard.
If ferrules are used the sole responsibility for a correct installation lies on the
installing party.