in Germany the ozone concentration occurring during the operation of
the system must not exceed the recommended value based on interna-
tional limits of 0.06 ml/m³ (0.12 mg/m³).
• Static on personnel
Static charges on personnel are unlikely if the bars are installed
properly. Personnel must wear conductive footwear.
Please note all national regulations regarding electrostatic charge
(e.g. TRGS 727 in Germany).
2.4 Protection against contact
The site of installation and/or use of the units is outside the control of
Eltex, contact protection against inadvertent contact of the bars and of live
components by personnel as specified by the employer’s liability insur-
ance association may have to be provided (e.g. DGUV V3 in Germany).
Contact protection devices made of conductive material must be
grounded.
2.5 Inspection of the protective resistors - contact protection
The function and the appearance of the protective resistors must be
inspected at regular intervals. The inspection intervals are specified in the
accident prevention regulations, as amended (e.g. in Germany DGUV
V3). Eltex recommend inspection intervals of 6 months.
The function of the series resistors must be checked using a suitable
measuring device. The test voltage must be 1,000V. The measured resis-
tance between the high-voltage connection and the individual emission tip
must not fall below 320 MOhm and not exceed 480 MOhm.
2.6 Technical progress
The manufacturer reserves the right to modify the technical specifications
in compliance with technical progress. Eltex are pleased to give you any
information on the current status of developments and on any changes
and modifications in the operating instructions.