BA-en-2088-2207_ES60
13
4. Operation
4.1 Startup
Before starting up the power supply the user must make sure that the
power supply and the bars have been installed and assembled correctly.
The supply voltage can then be switched on.
Use the toggle switch (4, Fig. 1) to switch on the power supply. In the ON
position the switch lights up green. High voltage is now supplied to the dis-
charging bars.
The output voltage is now a constant 5 kV AC.
If the fuse is defective, the switch will not light up.
4.2 Operating mode with conductive substrats
If electrically conductive substrates or substrates coated with conductive
material (e.g. metal foil or metal composites) are used, the mains supply
must be interrupted. The connected bars discharge the substrates like this
in passive operating mode.
Check for correct ground connection!