BA-en-2088-2207_ES60

11

3.5 Maximum active bar length and length of the high voltage cable

Both the lengths of the high voltage cable and of the active bars are 

limited. The shielded high voltage cables cause a capacitive load on the 
transformer inside the power supply. The maximum loading capacity is a 
result of the function of the total active bar length and the total length of all 
high voltage cables. Fig. 4 demonstrates this principle for R5x bars, ion 
blower nozzles R36E, ion blower heads R55E and ion bower pistols PR36 
and PR55.

Example: The maximum permissible total cable length with a 3 meter 
active bar length is 32 meters.

Fig. 5 demonstrates this principle for R47 and R6x bars.

Fig. 4:

Loading capacity 
of the Power 

Supply as factor of 
bar length and 
length of high 

voltage cable of 
R5x bars, R36E, 
R55E, PR36, 
PR55

Z000

50

e

Σ

 

lengths of h.v. cable [m]

Σ

 

lengths of active bars [m]

7.5

5.0

2.5

5      10     15     20     25

permissible

range

Fig. 5:

Loading capacity 
of the Power 

Supply as factor of 
bar length and 
length of high 

voltage cable of 
R47 and R6x bars

Z01

162d

Σ

 lengths of h.v. cable [m]

Σ

 lengths of active bars [m] 

10

 

 5

10    20     30     40     50

permissible

range

Содержание ES60 Series

Страница 1: ...Operating Instructions BASE IONIZER Series ES60 vario Power Supply for AC operation BA en 2088 2207 F01089y...

Страница 2: ...2 BA en 2088 2207_ES60...

Страница 3: ...ion blower pistols and distributors suitable for connection 10 3 4 Connecting the high voltage cable 10 3 5 Maximum active bar length and length of the high voltage cable 11 3 6 Connecting the supply...

Страница 4: ...supply features the following characteristics 5 plug type high voltage outputs stable 5 kV AC output voltage optional function monitoring small dimensions easy installation protection class IP54 desig...

Страница 5: ...d 2 High voltage terminals 5 pcs 3 Fuse type see name plate 4 ON OFF switch ON illuminated 5 Plug for functional signal only for functional monitoring optional 6 Grounding terminal 7 Mounting bracket...

Страница 6: ...ers will not assume any liability and warranty if the units are used improperly or used outside the intended purpose 2 2 Identification of risks and hazards Possible risks and hazards resulting from t...

Страница 7: ...t protection is no longer effective Always dis connect the power before opening the power supply units The protection class IP54 only applies if the housing cover is closed and the cable connections a...

Страница 8: ...to the emission tips of the discharging bar or if several emission tips are touched at the same time the appropriate warning notices must be displayed The operation of the bars can generate ozone The...

Страница 9: ...r supply is designed for wall mounting Attach using the brackets provided installation dimensions see Fig 2 The operating elements of the power supply and the terminals must be freely accessible at al...

Страница 10: ...ble 3 4 Connecting the high voltage cable Warning Connect or disconnect the high voltage cables only with the power supply switched off Connect the discharging bars to the power supply using the prefa...

Страница 11: ...zles R36E ion blower heads R55E and ion bower pistols PR36 and PR55 Example The maximum permissible total cable length with a 3 meter active bar length is 32 meters Fig 5 demonstrates this principle f...

Страница 12: ...h voltage is supplied to the bars in this case For external security of the power supply the following circuit breaker is re commended Tripping Characteristic 2A K according to DIN EN 60947 2 3 7 Conn...

Страница 13: ...n the switch lights up green High voltage is now supplied to the dis charging bars The output voltage is now a constant 5 kV AC If the fuse is defective the switch will not light up 4 2 Operating mode...

Страница 14: ...according to the operating conditions The power supply itself does not require any maintenance Check for correct ground connection 5 2 Discharging bars To ensure the trouble free function of the disc...

Страница 15: ...ny work involving the units must be carried out by qualified electrici ans Fault Cause Measure No high voltage Lamp in mains power switch lit transformer defective Lamp in mains power switch fails to...

Страница 16: ...V AC Current max 6 2 mA Frequency 50 60 Hz pluggable connections 5 Load capacity depending on bar type and length and high voltage cable length see chapter 3 5 Features Ion balance with and without pa...

Страница 17: ...BA en 2088 2207_ES60 17 8 Dimensions Z 118096y_2 Fig 7 Dimensions ES60 Power Supply...

Страница 18: ...ly ES60 Plug S Set for prefabricating the high voltage cable without flexible tube for power supply ES60 Flexible tube for high voltage cable specify length Blanking plug for high voltage connection M...

Страница 19: ...Industrial scientific and medical equipment Radio frequency disturbance characteristics Limits and methods of measurement Electromagnetic compatibility EMC Limits Limit for harmonic current emissions...

Страница 20: ...mbH Blauenstra e 67 69 79576 Weil am Rhein Germany Phone 49 0 7621 7905 422 eMail info eltex de Internet www eltex de Eltex offices and agencies The addresses of all Eltex agencies can be found on our...

Отзывы:

Похожие инструкции для ES60 Series