3.2 Ground connection
A permanent ground connection must be made via the grounding terminal
(5, Fig. 1). The ground cable should have a minimum cross section of
1.5 mm
2
.
3.3 Discharging bars, ion blower nozzles, ion blower pistols and
distributors suitable for connection
Eltex discharging bars for AC operation as well as the ion blower nozzles,
ion blower pistols and distributors can be connected to the ES60 power
supplies, each with a permanently connected high voltage cable.
3.4 Connecting the high voltage cable
Warning!
Connect or disconnect the high voltage cables only with the power supply
switched off!
Connect the discharging bars to the power supply using the prefabricated
high voltage cable. Push the high voltage cables into the sockets up to the
stop. Then secure the adapter in the socket with the clip provided (see
Fig. 3).
Cables without flexible tube and cables with plug-type adapters are
plugged in flush and secured with the clip.
Warning!
In applications involving moving bars, the high voltage cable must be
attached such that there is no cable movement near the connection zone
of the power supply unit.