12
BA-en-2088-2207_ES60
3.6 Connecting the supply voltage
Connect the supply voltage via the power supply lead (1, Fig. 1) using an
earthing pin plug (depending on cable version).
To ensure that no voltage is supplied to the bars when the material web is
at rest, enabling the supply voltage to the power supply via machine con-
tact is recommended. If the material web is at rest, or if the machine is not
in operation, no high voltage is supplied to the bars in this case.
For external security of the power supply the following circuit breaker is re-
commended: Tripping Characteristic 2A/K according to DIN EN 60947-2.
3.7 Connecting the function signal
The 5-pin connecting plug (Fig. 6) is only provided in units equipped with
function monitoring. The following signals can be picked up at this plug:
• Output voltage active: contact 1, 2, 5 (contact 1 and 5 closed)
Cables prefabricated at one end are available for connection to this plug
(see spare parts).
Fig. 6:
Assignment of the
plug for function
signals
(contacts at rest)