background image

10

Installation and commissioning

Weather Station Suntracer KNX-GPS light

 • Version: 15.07.2013 • Technical changes reserved. Errors reserved.

To remove it, the weather station can be simply pulled upwards out of the mount,
against the resistance of the fastening.

2.2. Notes on mounting and commissioning

Do not open   weather station if water (rain) might ingress: even some drops might
damage the electronic system. 

Observe the correct connections. Incorrect connections may destroy the weather sta-
tion or connected electronic devices. 

Please take care not to damage the temperature sensor (small blank at the bottom part
of the housing.) when mounting the weather station. Please also take care not to break
away or bend the cable connection between the blank and the rain sensor when con-
necting the weather station.

Remove all existing protection labels after installation.

The measured wind value and thus all other wind switching outputs may only be sup-
plied 60 seconds after the supply voltage has been connected.

After the auxiliary voltage has been applied, the device will enter an initialisation phase
lasting a few seconds. During this phase no information can be received via the bus.

Fig. 12
Make sure the cover and bottom part are 
properly snapped together! This picture is 
looking at the closed sensor from under-
neath.

Fastening

Fig. 13
Push the housing from above into the fas-
tened mount. The bumps on the mount must 
snap into the rails in the housing.

Содержание Suntracer KNX-GPS

Страница 1: ...cal specifications and installation instructions EN Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone 49 0 70 56 93 97 0 info elsner elektronik de Germany Fax...

Страница 2: ...oiseless and reliable even in case of hail snow and minus temperature Air swirls and up draught in the radius of the weather station are collected too Precipitation perception The surface of the senso...

Страница 3: ...mA Data output KNX bus terminal plug BCU type Own micro controller PEI type 0 Group addresses max 254 Allocations max 255 Communication objects 222 Heating rain sensor approx 1 2 W 230 V and 24 V Mea...

Страница 4: ...nstructions voids any and all warranty and guarantee claims After unpacking the device check it immediately for possible mechanical damage If it has been damaged in transport inform the supplier immed...

Страница 5: ...smitters and interfering fields from electricity consumers e g flu orescent lamps neon signs switched mode power supplies etc can interfere with or even cut out reception of the GPS signal 2 1 2 Mount...

Страница 6: ...n Collar Fig 5 Different mounting arms are available from El sner Elektronik as additional optional accesso ries for flexible installation of the weather station on a wall pole or beam Example of the...

Страница 7: ...eserved Errors reserved 2 1 4 Rear view and drill sketch Fig 7 Example use of the hinge arm mounting Fitting to a pole with worm drive hose clips Oblong hole 7 5 x 5 mm Fig 8 a b Drill sketch Dimensio...

Страница 8: ...arefully so as not to pull off the wire connecting the PCB in the bottom part with the rain sensor in the cover Push the power supply and bus connection cable through the rubber seal on the bot tom of...

Страница 9: ...ion clamp for auxiliary voltage supply For massive conductors of up to 1 5 mm or conductors with fine wires Terminal configuration independent from polarity or 2 KNX clamp 3 Slot for cable connection...

Страница 10: ...when mounting the weather station Please also take care not to break away or bend the cable connection between the blank and the rain sensor when con necting the weather station Remove all existing p...

Страница 11: ...Maintenance WARNING Risk of injury caused by components moved automatically The automatic control can start system components and place people in danger e g moving windows awnings if a rain wind alar...

Отзывы: