Description

Ventilation Unit WL800

 • Version: 28.04.2016 • Errors and technical modifications subject to change without notice.

1.

Description

The 

Ventilation Unit WL800

 is installed in the ridge area of conservatories replacing

the normal glazing. The 

WL800

 discharges air into the outer atmosphere (exhaust

mode) or circulates the air inside (circulation mode). 

The 

WL800

 communicates via radio with the building control systems WS1 and (KNX)

WS1000 Color or Style. Using an integrated temperature sensor inside the ventilation
unit, the building control systems can utilize the circulation mode to gain heat or to re-
duce water condensation. 

With the ventilation modules RF-WL, the 

Ventilation Unit WL800

 can be automati-

cally controlled in different levels. In addition to that, the 

WL800

 can be manually and

directly controlled via the radio remote control Remo 8, the pushbutton interface RF-
B2-UP or via the solar radio pushbuttons Corlo P RF.

Functions:

Exhaust mode 

and

 Circulation mode

Every 

WL800

 requires an air intake opening of not less than 18,360 mm² 

(Comfort: 38,400 mm²)

Air circulation to gain heat

 (Automatic function of control units WS1/

WS1000): Warm air from the ridge area is distributed throughout the whole 
room by the ventilation unit

Air circulation to reduce condensation water

 (Automatic function of 

control units WS1/WS1000): Using a special calculating process, the control 
units recognize critical conditions of temperature and dew point and start the 
ventilation unit, usually even before any moisture starts settling.

Wireless activation

.  Radio connection is automatically established after 

switching on of the mains voltage

Smoothly running radial fans

Continuously variable

Highly 

insulated and thermally decoupled housing

 (no cold bridges)

Extremely 

tight-closing flap

 with self-locking drive and load limit switch

Pressure-resistant mounting panel

Installation along with self-cleaning panes possible, due to silicon-free 
processing

Power and radio electronics arranged inside, but outside of the air flow. 
Maintenance possible entirely from inside

Automatic control and manual operation possible with the following control 
systems:
WS1 Color, WS1 Style, WS1000 Color, WS1000 Style, KNX WS1000 Color, 
KNX WS1000 Style (all from software version 1.811)

Automatic control possible with the following ventilation modules:
RF-WL, RF-WL 0-10 V

Manual operation possible with the following radio transmitters:
Remo 8 (from version 1.1), RF-B2-UP, Corlo P1 RF, Corlo P2 RF

Содержание 60461-60466

Страница 1: ...stallation instructions Item numbers 60461 60466 60471 60476 EN Technical support 49 0 70 33 30 945 250 Elsner Elektronik GmbH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de ...

Страница 2: ...nits WS1 WS1000 Warm air from the ridge area is distributed throughout the whole room by the ventilation unit Air circulation to reduce condensation water Automatic function of control units WS1 WS1000 Using a special calculating process the control units recognize critical conditions of temperature and dew point and start the ventilation unit usually even before any moisture starts settling Wirel...

Страница 3: ...oltage Supply 10 m Power consumption in exhaust mode minimal speed approx 8 W maximal speed approx 124 W Radio frequency 868 2 MHz Net air output Exhaust air max approx 555 m h Circulation air max approx 163 m h For exact measuring criteria please inquire at Elsner Elektronik Required air intake opening minimum 18 360 mm approx 184 cm Please observe the instructions in chapter Air intake opening p...

Страница 4: ... The tolerance for panel width and length for standard and custom sizes is 3 mm Minimum panel sizes at shortening or custom panel Requirement Ventilator combination Note Minimum 1 WL Z per 1 WL800 Air performance is achieved Draught may occur depending on building situa tion and utilization Comfort 2 WL Z per 1 WL800 Ventilator height Outside approx 150 mm Inside approx 165 mm at panel thickness o...

Страница 5: ...tions due to technical reasons are possible Due to the different nature of the surface of the panel and ventilator housing slightly different degrees of lustre can occur 2 Installation and start up 2 1 Installation notes Installation testing operational start up and troubleshooting should only be performed by an electrician DANGER Risk to life from live voltage mains voltage There are unprotected ...

Страница 6: ...nteed The range of wireless control will be limited by legal reg ulation and structural circumstances Avoid sources of interference and obstacles be tween receiver and transmitter that could disturb the wireless communication Those would be for example Walls and ceilings especially concrete and solar protection glazing Metal surfaces next to the wireless participants e g aluminium construction of ...

Страница 7: ...90 the additional option wall device must be ordered surcharge In case of mounting on a flat roof water on the panel must not exceed the height of 2 cm The air outlet must face the direction that is opposite to the weather side Leave sufficient distance to walls or ledges when installing the fan so that the blower unit can be easily removed for disassembly Keep a distance of at least 60mm to the w...

Страница 8: ...the ventilation unit for servicing Keep a distance of at least 60mm between the internal hood and the wall Fig 4 Leave sufficient room for disassembly of the blower unit The blower unit is 340mm in length Fig 5 To remove blower unit for servicing 1 Remove the screws on the internal hood and pull the hood down on the air discharge side 2 Shift the hood approx 60mm and remove it Internal hood at lea...

Страница 9: ...atically The building control system will display Device has been taught The fan will stop sending Learn telegrams once the reply taught for a learning pro cess or a control command in the event of a power failure during operation is re ceived from a control unit 4 Maintenance The function of the unit should be checked by the specialized dealer installation tech nician once a year and the ventilat...

Страница 10: ...hout notice Each time the OFF state is reached the speed change stops automatically so that a direct change between exhaust and circulation modes is impossible Fan OFF stopped flap closed Circulation air mode Press Increase speed Lower rotation speed to OFF Fan OFF Press Exhaust air mode Lower rotation speed to OFF Increase speed Fan OFF ...

Отзывы: