Installation and start-up

Ventilation Unit WL800

 • Version: 28.04.2016 • Errors and technical modifications subject to change without notice.

Do not use the device if it is damaged. 

Take the device or system out of service and secure it against
unintentional use, if it can be assumed, that risk-free operation is no
longer guaranteed.

The device is only to be used for its intended purpose. Any improper modification or
failure to follow the operating instructions voids any and all warranty and guarantee
claims.

After unpacking the device, check it immediately for possible mechanical damage. If it
has been damaged in transport, inform the supplier immediately.

The device may only be used as a fixed-site installation; that means only when assem-
bled and after conclusion of all installation and operational start-up tasks and only in
the surroundings designated for it.

Elsner Elektronik is not liable for any changes in norms and standards which may occur
after publication of these operating instructions.

2.2. Notes on wireless equipment

When planning facilities with devices that communicate via radio, adequate radio re-
ception must be guaranteed.  The range of wireless control will be limited by legal reg-
ulation and structural circumstances. Avoid sources of interference and obstacles be-
tween receiver and transmitter, that could disturb the wireless communication. Those
would be for example:

Walls and ceilings (especially concrete and solar protection glazing).

Metal surfaces next to the wireless participants (e. g. aluminium construction 
of a conservatory).

Other wireless devices and powerful local transmitters (e.g. wireless 
headphones), which transmit on the same frequency (868,2 MHz). Please 
maintain a minimum distance of 30 cm between wireless transmitters for that 
reason.

2.3. Instructions for simultaneous operation of a 

non-roomsealed firing installation

Non-roomsealed firing installations are e.g. heating devices operated with gas, oil,
wood or coal, flow heaters, water heaters, cookers and ovens that are supplied with
combustion air from the room where they are installed and that have an exhaust sys-
tem (e.g. chimney) through which the exhaust gas is discharged into the atmosphere.

WARNING!
Danger to life from toxic combustion gases!

If the ventilation unit is operated in exhaust mode simultaneously with 

a non-roomsealed firing installation in the same room or area, toxic 
combustion gases may be drawn from the chimney or vent into the room, if 
there is not enough supply air.

Содержание 60461-60466

Страница 1: ...stallation instructions Item numbers 60461 60466 60471 60476 EN Technical support 49 0 70 33 30 945 250 Elsner Elektronik GmbH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de ...

Страница 2: ...nits WS1 WS1000 Warm air from the ridge area is distributed throughout the whole room by the ventilation unit Air circulation to reduce condensation water Automatic function of control units WS1 WS1000 Using a special calculating process the control units recognize critical conditions of temperature and dew point and start the ventilation unit usually even before any moisture starts settling Wirel...

Страница 3: ...oltage Supply 10 m Power consumption in exhaust mode minimal speed approx 8 W maximal speed approx 124 W Radio frequency 868 2 MHz Net air output Exhaust air max approx 555 m h Circulation air max approx 163 m h For exact measuring criteria please inquire at Elsner Elektronik Required air intake opening minimum 18 360 mm approx 184 cm Please observe the instructions in chapter Air intake opening p...

Страница 4: ... The tolerance for panel width and length for standard and custom sizes is 3 mm Minimum panel sizes at shortening or custom panel Requirement Ventilator combination Note Minimum 1 WL Z per 1 WL800 Air performance is achieved Draught may occur depending on building situa tion and utilization Comfort 2 WL Z per 1 WL800 Ventilator height Outside approx 150 mm Inside approx 165 mm at panel thickness o...

Страница 5: ...tions due to technical reasons are possible Due to the different nature of the surface of the panel and ventilator housing slightly different degrees of lustre can occur 2 Installation and start up 2 1 Installation notes Installation testing operational start up and troubleshooting should only be performed by an electrician DANGER Risk to life from live voltage mains voltage There are unprotected ...

Страница 6: ...nteed The range of wireless control will be limited by legal reg ulation and structural circumstances Avoid sources of interference and obstacles be tween receiver and transmitter that could disturb the wireless communication Those would be for example Walls and ceilings especially concrete and solar protection glazing Metal surfaces next to the wireless participants e g aluminium construction of ...

Страница 7: ...90 the additional option wall device must be ordered surcharge In case of mounting on a flat roof water on the panel must not exceed the height of 2 cm The air outlet must face the direction that is opposite to the weather side Leave sufficient distance to walls or ledges when installing the fan so that the blower unit can be easily removed for disassembly Keep a distance of at least 60mm to the w...

Страница 8: ...the ventilation unit for servicing Keep a distance of at least 60mm between the internal hood and the wall Fig 4 Leave sufficient room for disassembly of the blower unit The blower unit is 340mm in length Fig 5 To remove blower unit for servicing 1 Remove the screws on the internal hood and pull the hood down on the air discharge side 2 Shift the hood approx 60mm and remove it Internal hood at lea...

Страница 9: ...atically The building control system will display Device has been taught The fan will stop sending Learn telegrams once the reply taught for a learning pro cess or a control command in the event of a power failure during operation is re ceived from a control unit 4 Maintenance The function of the unit should be checked by the specialized dealer installation tech nician once a year and the ventilat...

Страница 10: ...hout notice Each time the OFF state is reached the speed change stops automatically so that a direct change between exhaust and circulation modes is impossible Fan OFF stopped flap closed Circulation air mode Press Increase speed Lower rotation speed to OFF Fan OFF Press Exhaust air mode Lower rotation speed to OFF Increase speed Fan OFF ...

Отзывы: