4
Description
Ventilation Unit WL800
• Version: 28.04.2016 • Errors and technical modifications subject to change without notice.
Ventilator combinations ventilator WL800 with supply air unit WL-Z
1.1.2. Dimensions
Deviating panel thickness
Panels with deviating thickness 24-29 mm and 31-60 mm available for an additional
charge.
Deviating panel dimensions
A. Standard panel cut (Article numbers 60471-60476): Panel is cut from standard panel.
The ventilation unit must be positioned parallel to one of the panel edges.
B. Individual custom size: Panels larger than standard size and/or with deviating venti-
lator position (not parallel to one of the edges) on request.
Tolerance
The tolerance for panel width and length for standard and custom sizes is ± 3 mm.
Minimum panel sizes:
(at shortening or custom panel)
Requirement:
Ventilator combination:
Note:
Minimum
1 WL-Z per 1 WL800
Air performance is achieved. Draught
may occur depending on building situa-
tion and utilization
Comfort
2 WL-Z per 1 WL800
Ventilator height
Outside approx. 150 mm
Inside approx. 165 mm
(at panel thickness of 30 mm, with different thickness,
the hight inside changes respectively)
Ventilator width
approx. 651 mm
Ventilator depth
Outside approx. 304 mm
Inside approx. 254 mm
Standard panel
approx. 1050 mm x 750 mm (Width x Depth), thickness
approx. 30 mm.
The standard panel can be trimmed on three sides (see
Fig. 1, Page 5)
Minimum width
approx. 751 mm
plus
the measure needed for mounting on both sides
Minimum depth
approx. 405 mm
plus
the measure needed for mounting above and
below