Technical Manual MSR Universal Stage Controller

Page 13

Transmitter Connection MSR 3100 / 23100 (simplified picture)

10

relay K2

P E

N

M

M

19

1

3

18

O

K 1

N

N

L

8

6

7

11

9

relay K1

L

A C

L

2

4

28

0-10V DC

24V DC

D C

32

31

M

M

relay K4 

(resp. alarm)

15

12

14

13

17

relay K3

16

30

NDO

MSR 3100

4-20 m

A IN

R S

4 8 5

34

DO

29

DG x/xx

11

relay K2

P E

N

M

1

3 19

N

18

N

6

8

7

L

L

0-10V DC

OK 1

L

relay K1

2

4

31

38

32

M

M

M

12

14

9

10

13

17 15

16

M S R   3 1 0 0

relay K3

inlet-

(control)

sensor

ourlet-

sensor

relay K4 

(resp.alarm)

R S

4 8 5

N

D

O

D

O

37

36

35

30

29

Temperature Sensor Connection MSR 3100 / 23100
(for chillers, simplified picture)

3 6

M S R   3 1 0 0

3 8

3 7

R S

485

2 9

DO

NDO

3 0

b a c k r u n

forward

P r e s s o s t a t

Dimensions MSR 3100 / 23100 / 3100 ST

Pressostat
Connection
MSR 3100 /
23100

35(1.38)

59 (2.32)

26 (1.02)

39 (1.54)

46 (1.81)

1 0

1

2

3

4

5

7

6

8

9

2

M S R

1

P

1 2

1 1

E L R E H A

1 3 1 4 1 5 1 6 1 7 1 8 1 9

4

3

105 (4.13)

2 9

2 3

2 2

2 0 2 1

2 5 2 6

2 8

2 4

2 7

3 1

3 0

3 2

3 4 3 5 3 6

3 8

3 3

3 7

63 (2.48)

91 (3.58)

105 (4.13)

46 (1.81)

2

4

1

2

1 0

3

4

5

7

6

8

9

1 1

1 3

1 2

1 4 1 5 1 6 1 7 1 8 1 9

E L R E H A

2 0 2 1

2 9

2 3

2 2

2 5 2 6

2 8

2 4

2 7

3 0

3 2

3 1

3 4 3 5

3 3

3 6

3 8

3 7

P

M S R

1

3

63 (2.48)

91 (3.58)

114 (4.49)

59 (2.32)

39 (1.54)

35(1.38)

26 (1.02)

MSR 3100 ST

MSR 3100 ST

values in brackets
= inches

Содержание MSR 100 Series

Страница 1: ...ge Compressors l Inputs for 2 wire Pressure Transmitters Pressostat and Temperature Sensors l Automatic Base Load Change Stage Sequence Change l Autoadaptive Trend Recognition l Analogue Output 0 10V...

Страница 2: ...se order separately For usage with compressor compounds 2 wire pressure transmitter type DG 0 10 GSW with 4 20mA output signal For usage with condernser fans 2 wire pressure transmitter type DG 0 25 G...

Страница 3: ...utes Reading the current operating mode Press and hold P longer than 3 seconds One of this 3 values occur on the display 106 Mode for compressor compounds 206 Mode for condenser fans 300 Mode for brin...

Страница 4: ...value all stages will be switched OFF in 1 sec steps after P15 is run down alarm relay will be activated P15 X X X 88 Alarm time delay 0 0 0 0 60 min P16 X X X 70 Power stages of compressor resp fan 1...

Страница 5: ...setpoint 1 0 0 0 0 59 min P38 X X X 88 OFF time hours of 2nd setpoint 1 0 0 0 0 23 h P39 X X X 88 OFF time minutes of 2nd setpoint 1 0 0 0 0 59 min P40 X X X 88 Adress of the unit in a network 78 78 7...

Страница 6: ...ting From every state of the con troller 4 minutes after the last keypress the display switches back to the actual value Calibration of Transmitter and Actual Value A pressure transmitter delivers its...

Страница 7: ...on Stage Controller for Brine Chillers The control setpoint is pre set by P04 as a tempera ture value this is the set point for stage 1 at the same time There is no need for an access code The follow...

Страница 8: ...nd of the actual value and decides based on the captured data about the necessity of switching on off a machine A typical example of a conventional control is the following state Machines run the actu...

Страница 9: ...signal Because this output is scalable it can be used both to forward an image of the actual value P01 or as proportional controller output P42 fixes the actual value the analogue output delivers 10V...

Страница 10: ...m one transformer MSR 1100 only a double pole switch must be used to switched off the single positions If not the unit will be supplied by a half wave via the shielding andtheunitcontinuesworking depe...

Страница 11: ...wer Hold key P until _ _ _ appears Let go key P Select 2 _ _ by key condenser fan mode Push key P once def appears default values are loaded Actual values appear ready for start up Basic Configuration...

Страница 12: ...rward backrun Pressostat rear view with mounting frame 75 2 95 9 1 2 3 4 5 7 6 8 20 21 22 19 18 16 17 23 24 37 1 46 11 10 12 14 15 13 10 Multi Channel Controller F2 Mehrstufenregler ELREHA 15 A C D C...

Страница 13: ...p alarm RS 485 N D O D O 37 36 35 30 29 Temperature Sensor Connection MSR 3100 23100 for chillers simplified picture 36 MSR 3100 38 37 RS 485 29 D O N D O 30 backrun forward Pressostat Dimensions MSR...

Страница 14: ...K3 relay K4 alarm M M 14 9 10 12 11 13 15 29 N 24V DC f transmitter O K 1 D O 26 25 28 O K 2 30 MSR 5100 25100 with temperature sensors simplified pic 12 13 14 15 2 3 24 25 4 5 6 7 8 9 10 11 26 27 28...

Страница 15: ...28 24 22 18 F1 DO NDO RS 485 relay 4 alarm F2 4 20mA 14 10 12 z 6 OK1 OK2 8 2 N 4 4 20mA N 16 relay 3 28 32 30 26 24 22 20 18 F1 18VDC RS 485 NDO DO 0 10V DC relay 4 alarm F2 10 14 12 6 8 2 4 d relay...

Страница 16: ...lectromagnetic consistency IEC 1000 4 1 IEC 1000 4 2 IEC 1000 4 3 IEC 1000 4 4 IEC 1000 4 5 EN 55011 B EN 50081 part 1 and 2 EN 50082 part 1 and 2 EN 61010 part 1 EN 61010 1 A2 part 1 A1 This statemen...

Отзывы: