![ELPRO 105G Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/elpro/105g/105g_user-manual_2396029072.webp)
Chapter 4
Configuration
MAN_105G_1.5
Page
72
I/O Data Output Mapping Object, Class A1h
This object is setup dynamically via fieldbus write mappings through configuration software.
This data is also available as vendor specific Instance Attributes (96h to 9Bh) in the Assembly
Object.
ID#
Name
Service
Description
Semantics
Def,
Min,
Max
Type
01h
Revision
Get_attribute_all
Object
Revision
The revision
attribute
containing the
revision of the
object
1,
1,
1
UINT
Instance Attributes, Instance 01h
ID#
Name
Service
Description
Type
01h
Data
Get_attribute_single
Set_attribute_single
The data produced is configured from fieldbus
write mappings to I/O Input Instance 1.
Array of
USINT
02h
Data
Get_attribute_single
Set_attribute_single
The data produced is configured from fieldbus
write mappings to I/O Input Instance 2.
Array of
USINT
…
…
…
…
…
06h
Data
Get_attribute_single
Set_attribute_single
The data produced is configured from fieldbus
write mappings to I/O Input Instance 6.
Array of
USINT