Name of the result
function
Parameter 1
Parameter 2
Comments
Set function result to
variable
Variable number
The action result is stored
in the status variable
memory which may be
later used as an argument
for another action.
Reset timer 1 second
Counter number
Number of seconds
The counter is set when
the action result = 1
Reset timer 5 ms
Counter number
Number of milliseconds
The counter is set when
the action result = 1
Configurable bits set to
true
Type of device that is
supposed to set the bit
MSB bit number
When the action result =
1, the set MSB bit is sent
by the selected type of
device and causes the
reaction configured in the
action of another device
within the range.
Configurable bits set to
false
Type of device that is
supposed to clear the bit
MSB bit number
When the action result =
1, the cleared MSB bit is
sent by the selected type
of device and causes the
reaction configured in an
action of another device
within the range.
Force error mode
When the action result =
1, the device enters the
error mode. The device
will leave the error mode
only when the power
supply is reset.
Configurable output bits
False
MSB bit number
When the action result =
1, the cleared MSB bit is
sent and causes the
reaction configured in the
action of another device
within the range.
Configurable output bits
True
MSB bit number
When the action result =
1, the set MSB bit is sent
and causes the reaction
configured in an action of
another device within the
range.