Instruction manual
I ELOshield
Rev. 20
09.03.2020
Page 57 of 85
Switching on/off the autotest mode
The LEDs, display and acoustic alarm are
switched on during the autotest. The test
is completed by pressing the Q button. The
autotest is signaled by the blinking red
status LED. It is used to check the device
signaling system for correct operation.
Switching on/off the range test mode
During the range test, the correctness of the detection of the other ELOshield devices is
additionally tested. The range test is signaled by the blinking red status LED and the alarm
and safety zone LEDs. The range test is completed, when the pedestrian module is located
within any antenna module (A) zone.
Configurable bits LSB
– Settings for additional information sent to devices reacting to the
stationary/vehicle module. It is possible to define detailed actions of the stationary/vehicle
modules in the case of detecting a device with set configuration bits. By using the bits, it is
possible to configure groups of devices which may, e.g., open a specific gate (by means of
the stationary set).
Input settings
o
Negation of the first input
o
Negation of the second input
Output settings
– contains control settings for open collector (OC) outputs.
o
Open collector output 1 (OC1)
o
Open collector output 2 (OC2)
Configurable output settings:
o
Settings of periodicity of the signal generated at the output: activation and
deactivation time. A full signal period is the sum of activation and deactivation time.
o
The signal level is the percentage of the signal intensity at the output.