165ESK...
Art.-Nr./Art. No./Réf./N° art.: 9010017B01M
Version
: 1.0
Date
: 25.05.2016
7/15
Electrical data
Standard
165ESK00K . .
165ESK00J . .
Circuit breaker for operating
voltage
Rated current max.
Recommended characteristics
(load dependent):
fast-acting
1 A
✓
Backup safety output
✗
Diagnostic output fuse
✗
Internal electronic protection
(regenerated)
✓
Power consumption per input
max.
2,75 mA
Power consumption
(at full load) max.
23,75 W
Short-circuit detection
✓
Short-circuit recognition
✓
Technology
RFID
Possible actuator
165EBK001
Assured operating distance
(S
ao
)
DIN EN 60947-5-3:
2014-12
8 mm
Assured release distance (S
ar
)
DIN EN 60947-5-3:
2014-12
18 mm
Rated operating distance (S
n
)
DIN EN 60947-5-2:
2014-01
12 mm
Minimum sensing distance
(S
0
min)
0,5 mm
Repeat accuracy (R)
< 0,5 mm
Differential travel max.
2 mm
Possible actuator
(The unique coding actuator is
supplied with the safety sensor
included)
165EBK001
Offset actuator max.
+/- 8 mm