16
MODEL: eXperience 620
0.85
±
0.05mm
FEED DOG HEIGHT ADJUSTMENT
When the presser foot is lowered with the pressure dial set at "3", the highest position of the feed dog
should be 0.8 to 0.9 mm above the surface of the needle plate.
1. Set the pressure dial at "3" and lower the pressure foot then turn on the power switch.
2. Turn the handwheel toward you until the feed dog comes to its highest position.
3. Remove the bed cover (see page 7)
4. Loosen set screw (A) and nut.
5. Turn the adjusting screw (C) in the direction of "E" to raise the feed or turn the adjusting screw (C)
in the direction of "D" to lower the feed dog, so that the feed dog highest is from 0.85 mm above
the top surface of the needle plate.
6. Tighten the nut and set screw(A).
7. Attach the bed cover.
Pressure dial at 3
Standard foot
Surface of the needle plate
Feed dog
E (To raise)
D
(To lower)
Adjusting screw (C)
Nut (B)
Setscrew (A)